A high signal-to-background ratio H2S-specific fluorescent probe based on nucleophilic substitution and its bioimaging for generation H2S induced by Ca2+ in vivo
被引:21
|
作者:
Kang, Jin
论文数: 0引用数: 0
h-index: 0
机构:
Shanxi Univ, Inst Mol Sci, Key Lab Mat Energy Convers & Storage Shanxi Prov, Taiyuan 030006, Shanxi, Peoples R ChinaShanxi Univ, Inst Mol Sci, Key Lab Mat Energy Convers & Storage Shanxi Prov, Taiyuan 030006, Shanxi, Peoples R China
Kang, Jin
[1
]
Huo, Fangjun
论文数: 0引用数: 0
h-index: 0
机构:
Shanxi Univ, Res Inst Appl Chem, Taiyuan 030006, Shanxi, Peoples R ChinaShanxi Univ, Inst Mol Sci, Key Lab Mat Energy Convers & Storage Shanxi Prov, Taiyuan 030006, Shanxi, Peoples R China
Huo, Fangjun
[2
]
Yao, Yishan
论文数: 0引用数: 0
h-index: 0
机构:
Beijing Inst Pharmacol & Toxicol, State Key Lab Tocicol & Med Countermeasures, 27 Taiping Rd, Beijing 100850, Peoples R ChinaShanxi Univ, Inst Mol Sci, Key Lab Mat Energy Convers & Storage Shanxi Prov, Taiyuan 030006, Shanxi, Peoples R China
Yao, Yishan
[3
]
Yin, Caixia
论文数: 0引用数: 0
h-index: 0
机构:
Shanxi Univ, Inst Mol Sci, Key Lab Mat Energy Convers & Storage Shanxi Prov, Taiyuan 030006, Shanxi, Peoples R ChinaShanxi Univ, Inst Mol Sci, Key Lab Mat Energy Convers & Storage Shanxi Prov, Taiyuan 030006, Shanxi, Peoples R China
Yin, Caixia
[1
]
机构:
[1] Shanxi Univ, Inst Mol Sci, Key Lab Mat Energy Convers & Storage Shanxi Prov, Taiyuan 030006, Shanxi, Peoples R China
[2] Shanxi Univ, Res Inst Appl Chem, Taiyuan 030006, Shanxi, Peoples R China
[3] Beijing Inst Pharmacol & Toxicol, State Key Lab Tocicol & Med Countermeasures, 27 Taiping Rd, Beijing 100850, Peoples R China
H2S-Specific;
Two nucleophilic;
Ca2+ mediated;
Vivo;
IMAGING HYDROGEN-SULFIDE;
SELECTIVE DETECTION;
LIVING CELLS;
MITOCHONDRIA;
HYPERTENSION;
MECHANISMS;
THIOLYSIS;
CYSTEINE;
D O I:
10.1016/j.dyepig.2019.107755
中图分类号:
O69 [应用化学];
学科分类号:
081704 ;
摘要:
Hydrogen sulfide (H2S), a new endothelium-derived relaxing factor (EDRF), which plays vital roles in regulating intracellular redoxstatus and other fundamental signaling processes involved in human health and disease. In this work, we designed a fluorescent probe for H2S successive nucleophilic reaction with high signal-to-background (S/B) ratio. In the probe, we utilized 2-mercaptobenzoic acid as the distinguish reaction site and introduced 2,4-dinitrophenyl to provide appropriate steric hindrance to realize specific response on well-structured H2S. Other substances sulfur-containing do not disturb the detection of H2S. The max emission with 197-fold enhancement exhibits high signal-to-background ratio. The detection limit was calculated to be 64 nM. Imaging assays in living cells showed that the probe could penetrate cells membrane easily and allowed to detect endogenous generation H2S induced by Ca2+ mediated cystathionine gamma-lyase (CSE). Moreover, the probe was successfully used to detect exogenous H2S in mice.