The effect of adjuvant calcium phosphate coating on a porous-coated femoral stem

被引:8
|
作者
Tanzer, M
Gollish, J
Leighton, R
Orrell, K
Giacchino, A
Welsh, P
Shea, B
Wells, G
机构
[1] McGill Univ, Montreal Gen Hosp, Div Orthopaed Surg, Montreal, PQ H3A 2T5, Canada
[2] Univ Toronto, Orthopaed & Arthrit Hosp, Div Orthopaed Surg, Toronto, ON, Canada
[3] Dalhousie Univ, Victoria Gen Hosp, Div Orthopaed Surg, Halifax, NS, Canada
[4] Sydney Hosp, Sydney, NS, Canada
[5] Ottawa Gen Hosp, Div Orthopaed Surg, Ottawa, ON K1H 8L6, Canada
[6] Univ Ottawa, Dept Epidemiol & Community Hlth, Ottawa, ON, Canada
关键词
D O I
10.1097/01.blo.0000128282.05708.9a
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A prospective, randomized, double-blind, multicenter trial was done to determine if the addition of hydroxyapatite and tricalcium phosphate to the porous coating of a cementless femoral component would result in improved clinical and radiographic outcomes. Patients were randomized to receive identical porous-coated stems with (n = 159 hips) or without (n = 159 hips) hydroxyapatite and tricalcium phosphate coating. At 2 to 5 years followup (mean, 37 months), no implants were revised for aseptic loosening. There was no difference in clinical function between the two groups with respect to the Harris hip score or Western Ontario and McMaster Universities Osteoarthritis Index scores. Bony ingrowth occurred frequently in both groups with 99% of the hydroxyapatite and tricalcium phosphate group and 98% of the control group showing radiographic evidence of osseointegration. Implants coated with hydroxyapatite and tricalcium phosphate had significantly fewer radiolucencies adjacent to the porous coating, indicative of improved osseointegration. Radiolucencies were present in Gruen Zones 1, 7, 8, or 14 in 25% of the control group and in 7% of the hydroxyapatite and tricalcium phosphate group. This improved osseointegration could serve as an added barrier to particulate debris migration and increase the long-term survivorship of the implant.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 50 条
  • [21] INGROWTH OF BONE IN FAILED FIXATION OF POROUS-COATED FEMORAL COMPONENTS
    JASTY, M
    BRAGDON, CR
    MALONEY, WJ
    HAIRE, T
    HARRIS, WH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (09): : 1331 - 1337
  • [22] THE EFFECT OF STEM STIFFNESS ON FEMORAL BONE-RESORPTION AFTER CANINE POROUS-COATED TOTAL HIP-ARTHROPLASTY
    BOBYN, JD
    GLASSMAN, AH
    GOTO, H
    KRYGIER, JJ
    MILLER, JE
    BROOKS, CE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (261) : 196 - 213
  • [23] Osseointegration of hydroxyapatite porous-coated femoral implants in a canine model
    Karabatsos, B
    Myerthall, SL
    Fornasier, VL
    Binnington, A
    Maistrelli, GL
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 442 - 449
  • [24] POROUS-COATED FEMORAL COMPONENTS IN A CANINE MODEL FOR REVISION ARTHROPLASTY
    ROBERSON, JR
    SPECTOR, M
    BAGGETT, MA
    KITA, K
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (08): : 1201 - 1208
  • [25] Bilayered calcium phosphate coating to promote osseointegration of a femoral stem prosthesis
    E. Goyenvalle
    N. J. M. Guyen
    E. Aguado
    N. Passuti
    G. Daculsi
    Journal of Materials Science: Materials in Medicine, 2003, 14 : 219 - 227
  • [26] Bilayered calcium phosphate coating to promote osseointegration of a femoral stem prosthesis
    Goyenvalle, E
    Guyen, NJM
    Aguado, E
    Passuti, N
    Daculsi, G
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2003, 14 (03) : 219 - 227
  • [27] Extensively Porous-coated Stems for Femoral Revision: Reliable Choice for Stem Revision in Paprosky Femoral Type III Defects
    Chung, Lien-Hsiang
    Wu, Po-Kuei
    Chen, Cheng-Fong
    Chen, Wei-Ming
    Chen, Tain-Hsiung
    Liu, Chien-Lin
    ORTHOPEDICS, 2012, 35 (07) : E1017 - E1021
  • [28] Intraoperative complications of revision hip arthroplasty using a porous-coated, distally slotted, fluted femoral stem
    Issack, PS
    Guerin, J
    Butler, A
    Marwin, SE
    Bourne, RB
    Rorabeck, CH
    Barrack, RL
    Di Cesare, PE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (425) : 173 - 176
  • [29] THE EFFECT OF FEMORAL STEM GEOMETRY ON INTERFACE MOTION IN UNCEMENTED POROUS-COATED TOTAL HIP PROSTHESES - COMPARISON OF STRAIGHT-STEM AND CURVED-STEM DESIGNS
    CALLAGHAN, JJ
    FULGHUM, CS
    GLISSON, RR
    STRANNE, SK
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06): : 839 - 848
  • [30] FEMORAL REVISION HIP-ARTHROPLASTY WITH UNCEMENTED, POROUS-COATED STEMS
    MORELAND, JR
    BERNSTEIN, ML
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (319) : 141 - 150