The Frequency Response of Acoustic Doppler Current Profilers Spatiotemporal response and implications for tidal turbine site assessment

被引:0
|
作者
Guion, Romain U. G. [1 ]
Young, Anna M. [1 ]
机构
[1] Univ Cambridge, Whittle Lab, Cambridge, England
来源
关键词
ADCP; response; spatiotemporal; filter; dispersion relationships; capture; turbulence; tidal; turbines; energy site; TURBULENCE;
D O I
暂无
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
The lifespan of a tidal turbine is strongly affected by the unsteady loading it experiences, so knowledge of the mean flow speed is not sufficient: unsteadiness must also be quantified. One of the most common turbulence measurement devices in the marine environment is the Acoustic Doppler Current Profiler (ADCP). The variance of steady velocity measurements from ADCPs has been studied in detail, but very little attention has been given to the fundamental limits of ADCPs in terms of the frequencies and lengthscales that they can capture. In this paper, it is shown that the ADCP acts as a low-pass filter to eddies and that even optimistic calculations predict significant attenuation at lengthscales up to ten times the blade chord of a typical tidal turbine. For a typical 40 m deep channel wavelengths below 3-4 m are attenuated by 90% or more. Those eddies that are not filtered out are then subject to a distortion that will either amplify or attenuate the signal depending on the precise turbulence characteristics of the site in question. While this low-pass filtering may alter some global statistics by truncating the observed spectrum, it is most damaging when data is extracted for particular frequencies, as a turbine designer may do when assessing unsteady loading and fatigue life. It is therefore recommended that high-resolution turbulence data, e.g. from a hotwire, is captured over part of the water column and that this is used to calibrate ADCP data.
引用
收藏
页数:10
相关论文
共 34 条
  • [31] Discrepant longitudinal volumetric and metabolic evolution of diffuse intrinsic Pontine gliomas during treatment: implications for current response assessment strategies
    Loebel, U.
    Hwang, S.
    Edwards, A.
    Li, Y.
    Li, X.
    Broniscer, A.
    Patay, Z.
    NEURORADIOLOGY, 2016, 58 (10) : 1027 - 1034
  • [32] Discrepant longitudinal volumetric and metabolic evolution of diffuse intrinsic Pontine gliomas during treatment: implications for current response assessment strategies
    U. Löbel
    S. Hwang
    A. Edwards
    Y. Li
    X. Li
    A. Broniscer
    Z. Patay
    Neuroradiology, 2016, 58 : 1027 - 1034
  • [33] Noninvasive assessment of tumor vasculature response to radiation-mediated, vasculature-targeted therapy using quantified power Doppler sonography - Implications for improvement of therapy schedules
    Kim, Dong Wook Nathan
    Huamani, Jessica
    Niermann, Kenneth J.
    Lee, Haakil
    Geng, Ling
    Leavitt, Lauren L.
    Baheza, Richard A.
    Jones, Cameron C.
    Tumkur, Shiv
    Yankeelov, Thomas E.
    Fleischer, Arthur C.
    Hallahan, Dennis E.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (12) : 1507 - 1517
  • [34] Assessment of therapeutic response in hepatocellular carcinoma treated with percutaneous radio frequency ablation - Comparison of multiphase helical computed tomography and power Doppler ultrasonography with a microbubble contrast agent
    Choi, DG
    Lim, HK
    Kim, SH
    Lee, WJ
    Jang, HJ
    Kim, H
    Lee, SJ
    Lim, JH
    JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (04) : 391 - 401