A comparison between laser interferometric measurement of fundus pulsation and pneumotonometric measurement of pulsatile ocular blood flow 1. Baseline considerations

被引:55
|
作者
Schmetterer, L
Dallinger, S
Findl, O
Eichler, HG
Wolzt, M
机构
[1] Univ Vienna, Dept Clin Pharmacol, A-1090 Vienna, Austria
[2] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
[3] Univ Vienna, Dept Ophthalmol, Vienna, Austria
关键词
fundus pulsation; ocular blood flow; pneumotonometry;
D O I
10.1038/eye.2000.9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Several methods have been proposed for the investigation of the human choroidal circulation. The aim of the present study was to compare laser interferometric measurements of cardiac synchronous fundus pulsations with pneumotonometric measurements of intraocular pressure pulse and pulsatile ocular blood flow in humans. Methods The association between fundus pulsation amplitude as assessed with laser interferometry and pulse amplitude (PA) and pulsatile ocular blood flow (POBF) as assessed with pneumotonometry was investigated in 28 healthy subjects. Additionally, we investigated the distribution of fundus pulsation amplitude (FPA) in a region of -15 degrees to +15 degrees around the macula (n = 18) and the influence of accommodation paralysis with cyclopentolate on FPA (n = 10). Results There was a high association between FPA and PA (r = 0.86, p < 0.001) and FPA and POBF (r = 0.70, p < 0.001). Fundus pulsations in the macula were significantly smaller than in the optic disc, but significantly larger than those in peripheral regions of the retina. Administration of cyclopentolate did not influence FPA. Conclusions On the basis of the strong correlation between laser interferometric measurements of FPA and pneumotonometric measurements of PA and POBF, we conclude that the FPA is a valid index of pulsatile choroidal perfusion in humans.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 50 条
  • [21] SYSTEMS-THEORY OF THE PULSED DOPPLER TECHNIQUE FOR BLOOD-FLOW MEASUREMENT .1.
    HASSLER, D
    ULTRASCHALL IN DER MEDIZIN, 1987, 8 (02): : 102 - 107
  • [22] MEASUREMENT METHOD OF THE POWDER FLOW CONDITION BETWEEN A MOLD AND A CC SLAB .1. THE DEVELOPMENT OF THE POWDER FILM THICKNESS MEASUREMENT
    NAKAMORI, Y
    ICHIKO, O
    WASITANI, T
    TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1983, 23 (12) : B404 - B404
  • [23] NONINVASIVE MEASUREMENT OF SKIN BLOOD-FLOW - COMPARISON BETWEEN PLETHYSMOGRAPHY, LASER-DOPPLER FLOWMETER AND HEAT THERMAL CLEARANCE METHOD
    SAUMET, JL
    DITTMAR, A
    LEFTHERIOTIS, G
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (01): : 73 - 83
  • [24] ACCURATE MEASUREMENT OF CEREBRAL METABOLISM IN THE CONSCIOUS, UNRESTRAINED NEONATAL PIGLET .1. BLOOD-FLOW
    WOOTTON, R
    FLECKNELL, PA
    JOHN, M
    BIOLOGY OF THE NEONATE, 1982, 41 (5-6): : 209 - 220
  • [25] POTENTIAL ERROR IN THE MEASUREMENT OF TISSUE TO BLOOD DISTRIBUTION COEFFICIENTS IN PHYSIOLOGICAL PHARMACOKINETIC MODELING - RESIDUAL TISSUE BLOOD .1. THEORETICAL CONSIDERATIONS
    KHOR, SP
    MAYERSOHN, M
    DRUG METABOLISM AND DISPOSITION, 1991, 19 (02) : 478 - 485
  • [26] Quantitative Tissue Blood Flow Measurement of the Liver Parenchyma: Comparison Between Xenon CT and Perfusion CT
    Kazuhiko Hashimoto
    Takamichi Murakami
    Keizo Dono
    Masatoshi Hori
    Tonsok Kim
    Masayuki Kudo
    Shigeru Marubashi
    Atsushi Miyamoto
    Yutaka Takeda
    Hiroaki Nagano
    Koji Umeshita
    Hironobu Nakamura
    Morito Monden
    Digestive Diseases and Sciences, 2007, 52 : 943 - 949
  • [27] Quantitative tissue blood flow measurement of the liver parenchyma: Comparison between xenon CT and perfusion CT
    Hashimoto, Kazuhiko
    Murakami, Takamichi
    Dono, Keizo
    Hori, Masatoshi
    Kim, Tonsok
    Kudo, Masayuki
    Marubashi, Shigeru
    Miyamoto, Atsushi
    Takeda, Yutaka
    Nagano, Hiroaki
    Umeshita, Koji
    Nakamura, Hironobu
    Monden, Morito
    DIGESTIVE DISEASES AND SCIENCES, 2007, 52 (04) : 943 - 949
  • [28] MEASUREMENT OF ORGAN BLOOD-FLOW USING TRITIATED-WATER .1. HINDLIMB MUSCLE BLOOD-FLOW IN CONSCIOUS EWES
    ODDY, VH
    BROWN, BW
    JONES, AW
    AUSTRALIAN JOURNAL OF BIOLOGICAL SCIENCES, 1981, 34 (04) : 419 - 425
  • [29] Comparison of two laser Doppler systems on the measurement of blood flow of premolar teeth under different pulpal conditions
    Mesaros, S
    Trope, M
    Maixner, W
    Burkes, EJ
    INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (03) : 167 - 174
  • [30] BLOOD FLOW MEASUREMENT THROUGH SINGLE CORONARY ARTERIES BY ROENTGEN DENSITOMETRY .1. A COMPARISON OF FLOW MEASURED BY A RADIOLOGIC TECHNIQUE APPLICABLE IN INTACT ORGANISM AND BY ELECTROMAGNETIC FLOWMETER
    RUTISHAU.W
    BUSSMANN, WD
    NOSEDA, G
    MEIER, W
    WELLAUER, J
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1970, 109 (01): : 12 - &