Numerical study of a PCM-air heat exchanger's thermal performance

被引:1
|
作者
Herbinger, F. [1 ]
Bhouri, M. [1 ]
Groulxl, D. [1 ]
机构
[1] Dalhousie Univ, Mech Engn Dept, Halifax, NS, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
STORAGE-SYSTEM; MODEL; BUILDINGS;
D O I
10.1088/1742-6596/745/3/032127
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, the use of PCMs in IIVAC applications is investigated by studying numerically the thermal performance of a PCM-air heat exchanger. The PCM used in this study is dodecanoic acid. A symmetric 3D model, incorporating conductive and convective heat transfer (air only) as well as laminar flow, was created in COMSOL Multiphysics 5.0. Simulations examined the dependence of the heat transfer rate on the temperature and velocity of the incoming air as well as the size of the chamiels in the heat exchanger. Results indicated that small channels size lead to a higher heat transfer rates. A similar trend was also obtained for high incoming air temperature, whereas the heat transfer rate was less sensitive to the incoming air velocity.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Numerical Research and Parametric Study on the Thermal Performance of a Vertical Earth-to-Air Heat Exchanger System
    Zhang, Zhening
    Sun, Jindong
    Zhang, Zhenxing
    Jia, Xinxin
    Liu, Yang
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2021, 2021
  • [32] Effect of PCM based heat exchanger for defrosting on performance of air source heat pump
    School of Municipal and Environment, Harbin Institute of Technology, Harbin 150090, China
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban), 2009, 10 (908-912):
  • [33] Mathematical modelling of PCM air heat exchanger
    Hed, G
    Bellander, R
    ENERGY AND BUILDINGS, 2006, 38 (02) : 82 - 89
  • [34] Numerical study on thermal performance of a BOG heat exchanger in the inclined condition
    Yan, Yan
    Ni, Zhonghua
    Zhi, Xiaoqin
    Yin, Jingsong
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 34 : 616 - 626
  • [35] Numerical study on thermal hydraulic performance of a Printed Circuit Heat Exchanger
    Figley, Justin
    Sun, Xiaodong
    Mylavarapu, Sai K.
    Hajek, Brian
    PROGRESS IN NUCLEAR ENERGY, 2013, 68 : 89 - 96
  • [36] Numerical study of earth-to-air heat exchanger: The effect of thermal insulation
    Xaman, J.
    Hernandez-Perez, I.
    Arce, J.
    Alvarez, G.
    Ramirez-Davila, L.
    Noh-Pat, F.
    ENERGY AND BUILDINGS, 2014, 85 : 356 - 361
  • [37] Numerical study on a new spiral fin heat Exchanger's thermal-hydraulic performance
    Liu, Junjie
    Uglanov, Dmitry A.
    Kedam, Naresh
    Shimanov, a. Artem
    Zhang, Bowen
    Shimanova, Alexandra B.
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [38] The Optimization of the Thermal Performances of an Earth to Air Heat Exchanger for an Air Conditioning System: A Numerical Study
    Greco, Adriana
    Masselli, Claudia
    ENERGIES, 2020, 13 (23)
  • [39] Experimental and numerical investigation of a real-scale air to multiple PCM heat exchanger
    Kareem, Bashir Eskander
    Adham, Ahmed Mohammed
    Yaqob, Banipal Nanno
    JOURNAL OF BUILDING ENGINEERING, 2024, 89
  • [40] Performance analysis of an improved PCM-to-air heat exchanger for building envelope applications - An experimental study
    Dardir, Mohamed
    Roccamena, Letizia
    El Mankibi, Mohamed
    Haghighat, Fariborz
    SOLAR ENERGY, 2020, 199 : 704 - 720