Dimethyl phthalate degradation at novel and efficient electro-Fenton cathode

被引:85
|
作者
Wang, Yi [1 ]
Liu, Yuhui [1 ]
Liu, Tianfu [1 ]
Song, Shuqin [2 ]
Gui, Xuchun [2 ]
Liu, Hong [1 ,3 ]
Tsiakaras, Panagiotis [4 ]
机构
[1] Sun Yat Sen Univ, Sch Chem & Chem Engn, KLGHEI Environm & Energy Chem, Key Lab Low Carbon Chem & Energy Conservat Guangd, Guangzhou 510275, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Sch Phys & Engn, State Key Lab Optoelect Mat & Technol, Key Lab Low Carbon Chem & Energy Conservat Guangd, Guangzhou 510275, Guangdong, Peoples R China
[3] Chinese Acad Sci, Chongqing Inst Green & Intelligent Technol, Chongqing 401122, Peoples R China
[4] Univ Thessaly, Sch Engn, Dept Mech Engn, Pedion Areas 38334, Volos, Greece
关键词
Carbon nanotube sponge; Electra-Fenton; H2O2; generation; Dimethyl phthalate; DYEING WASTE-WATER; CARBON NANOTUBES; CHEMICAL OXIDATION; ACTIVATED CARBON; CATALYST; REMOVAL; DYES; MINERALIZATION; DESTRUCTION; REDUCTION;
D O I
10.1016/j.apcatb.2014.02.041
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A novel three-dimensional porous carbon nanotube sponge (CNTS) with high electrical conductivity was prepared, characterized and investigated as the catalytic cathode for oxygen reduction and employed for an electro-Fenton process to degrade dimethyl phthalate (DMP) in aqueous solution. For comparison, the conventional electro-Fenton cathode, graphite gas diffusion electrode (GDE) and graphite electrode, was also tested. Experiments showed that the side reaction of H-2 evolution was avoided and the H2O2 accumulation concentration arrived at the maximal value at CNTS cathode as the cathode potential was set at -0.5 V (vs. SCE). The apparent rate constant for DMP degradation was 0.057 min(-1) at CNTS cathode, much higher than 0.005 min(-1) at graphite cathode and 0.011min(-1) at graphite GDE. Meanwhile, CNTS possessed desirable stability without performance decay after 20 times reaction. It was also found that more negative cathode potential than -0.5 V could cause the side reaction of H2 evolution and thus leading to a deteriorated DMP degradation. Moreover, the initial DMP concentration affected the apparent rate constant of DMP degradation. Compared to the case of higher initial DMP concentration, DMP degraded faster in the case of lower initial DMP concentration. The pH value and initial Fe2+ concentration for DMP degradation at CNTS cathode were optimized to be 3.0 and 0.5 mmol L-1, respectively. The CNTS is promising to be potentially used as the cathode for electro-Fenton system to remove organic pollutants in wastewater. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [41] High performance and durable graphene-grafted cathode for electro-Fenton degradation of tetramethyldecynediol
    Wang, Zuxin
    Olvera-Vargas, Hugo
    Martins, Marcos Vinicius Surmani
    Garcia-Rodriguez, Orlando
    Garaj, Slaven
    Lefebvre, Olivier
    CHEMICAL ENGINEERING JOURNAL, 2023, 455
  • [42] Degradation of levofloxacin by electro-Fenton with CNT supported nano-iron cathode.
    Feng, Fan
    Guo, Bo
    Cao, Qun
    Jin, Shi-Yi
    Wang, Rui-Lin
    Chen, Cai-Yu
    Zhongguo Huanjing Kexue/China Environmental Science, 2024, 44 (10): : 5513 - 5521
  • [43] Design of an electro-Fenton system with a novel sandwich film cathode for wastewater treatment
    Fan, Yan
    Ai, Zhihui
    Zhang, Lizhi
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 176 (1-3) : 678 - 684
  • [44] Degradation of Alizarin Red by electro-Fenton process using a graphite-felt cathode
    Panizza, Marco
    Oturan, Mehmet A.
    ELECTROCHIMICA ACTA, 2011, 56 (20) : 7084 - 7087
  • [45] Coumaric acid degradation by electro-Fenton process
    Elaoud, Sourour Chaabane
    Panizza, Marco
    Cerisola, Giacomo
    Mhiri, Tahar
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 667 : 19 - 23
  • [46] Electro-Fenton degradation of antimicrobials triclosan and triclocarban
    Sires, Ignasi
    Oturan, Nihal
    Oturan, Mehmet A.
    Rodriguez, Rosa Maria
    Garrido, Jose Antonio
    Brillas, Enric
    ELECTROCHIMICA ACTA, 2007, 52 (17) : 5493 - 5503
  • [47] Kinetics and mechanisms of oxytetracycline degradation in an electro-Fenton system with a modified graphite felt cathode
    Lai, Weikang
    Xie, Guangyan
    Dai, Ruizhi
    Kuang, Chaozhi
    Xu, Yanbin
    Pan, Zhanchang
    Zheng, Li
    Yu, Ling
    Ye, Shengjun
    Chen, Zhuoyao
    Li, Hang
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2020, 257 (257)
  • [48] Efficient removal of dimethyl phthalate with activated iron-doped carbon aerogel through an integrated adsorption and electro-Fenton oxidation process
    Zhao, Hongying
    Wang, Qingning
    Chen, Ying
    Tian, Qingling
    Zhao, Guohua
    CARBON, 2017, 124 : 111 - 122
  • [49] Methyl red degradation by the electro-fenton process
    Yu, Qinghong
    Zhou, Minghua
    Lei, Lecheng
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [50] Zeolitic imidazolate framework-8 modified active carbon fiber as an efficient cathode in electro-Fenton for tetracycline degradation
    Yu, Fangke
    Wang, Lina
    Ma, Hongrui
    Pan, Yuwei
    SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 237