Dimethyl phthalate degradation at novel and efficient electro-Fenton cathode

被引:85
|
作者
Wang, Yi [1 ]
Liu, Yuhui [1 ]
Liu, Tianfu [1 ]
Song, Shuqin [2 ]
Gui, Xuchun [2 ]
Liu, Hong [1 ,3 ]
Tsiakaras, Panagiotis [4 ]
机构
[1] Sun Yat Sen Univ, Sch Chem & Chem Engn, KLGHEI Environm & Energy Chem, Key Lab Low Carbon Chem & Energy Conservat Guangd, Guangzhou 510275, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Sch Phys & Engn, State Key Lab Optoelect Mat & Technol, Key Lab Low Carbon Chem & Energy Conservat Guangd, Guangzhou 510275, Guangdong, Peoples R China
[3] Chinese Acad Sci, Chongqing Inst Green & Intelligent Technol, Chongqing 401122, Peoples R China
[4] Univ Thessaly, Sch Engn, Dept Mech Engn, Pedion Areas 38334, Volos, Greece
关键词
Carbon nanotube sponge; Electra-Fenton; H2O2; generation; Dimethyl phthalate; DYEING WASTE-WATER; CARBON NANOTUBES; CHEMICAL OXIDATION; ACTIVATED CARBON; CATALYST; REMOVAL; DYES; MINERALIZATION; DESTRUCTION; REDUCTION;
D O I
10.1016/j.apcatb.2014.02.041
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A novel three-dimensional porous carbon nanotube sponge (CNTS) with high electrical conductivity was prepared, characterized and investigated as the catalytic cathode for oxygen reduction and employed for an electro-Fenton process to degrade dimethyl phthalate (DMP) in aqueous solution. For comparison, the conventional electro-Fenton cathode, graphite gas diffusion electrode (GDE) and graphite electrode, was also tested. Experiments showed that the side reaction of H-2 evolution was avoided and the H2O2 accumulation concentration arrived at the maximal value at CNTS cathode as the cathode potential was set at -0.5 V (vs. SCE). The apparent rate constant for DMP degradation was 0.057 min(-1) at CNTS cathode, much higher than 0.005 min(-1) at graphite cathode and 0.011min(-1) at graphite GDE. Meanwhile, CNTS possessed desirable stability without performance decay after 20 times reaction. It was also found that more negative cathode potential than -0.5 V could cause the side reaction of H2 evolution and thus leading to a deteriorated DMP degradation. Moreover, the initial DMP concentration affected the apparent rate constant of DMP degradation. Compared to the case of higher initial DMP concentration, DMP degraded faster in the case of lower initial DMP concentration. The pH value and initial Fe2+ concentration for DMP degradation at CNTS cathode were optimized to be 3.0 and 0.5 mmol L-1, respectively. The CNTS is promising to be potentially used as the cathode for electro-Fenton system to remove organic pollutants in wastewater. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] Design of a novel and efficient electro-Fenton cathode with skeleton of melamine foams
    Zhang, Yimei
    Chen, Zhuang
    Wu, Panpan
    Duan, Yaxiao
    Zhao, Yalong
    Zhou, Lincheng
    Lai, Yuxian
    Wang, Fei
    MATERIALS LETTERS, 2019, 239 : 196 - 199
  • [2] Electro-Fenton approach in oxidative degradation of dimethyl phthalate - The treatment of aqueous leachate from landfills
    Dolatabadi, Maryam
    Swiergosz, Tomasz
    Ahmadzadeh, Saeid
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 772
  • [3] Degradation of nitrophenols by cathode reduction and Electro-Fenton methods
    Yuan, Songhu
    Tian, Meng
    Cui, Yanping
    Lin, Li
    Lu, Xiaohua
    Progress of Green Oxidation/Reduction Technologies, 2006, : 22 - 25
  • [4] A highly efficient cathode based on modified graphite felt for aniline degradation by electro-Fenton
    Ou, Bin
    Wang, Jixiao
    Wu, Ying
    Zhao, Song
    Wang, Zhi
    CHEMOSPHERE, 2019, 235 : 49 - 57
  • [5] Efficient degradation of diisobutyl phthalate in aqueous solution through electro-Fenton process with sacrificial anode
    Yang, Zhenqi
    Chen, Huilun
    Wang, Jihong
    Yuan, Rongfang
    Wang, Fei
    Zhou, Beihai
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2020, 8 (05):
  • [6] Assessment of photo electro-Fenton and solar photo electro-Fenton processes for the efficient degradation of asulam herbicide
    Vigil-Castillo H.H.
    Ruiz-Ruiz E.J.
    López-Velázquez K.
    Hinojosa-Reyes L.
    Gaspar-Ramírez O.
    Guzmán-Mar J.L.
    Chemosphere, 2023, 338
  • [7] A novel sulfite coupling electro-fenton reactions with ferrous sulfide cathode for anthracene degradation
    Chu, Longgang
    Sun, Zhaoyue
    Cang, Long
    Fang, Guodong
    Wang, Xinghao
    Zhou, Dongmei
    Gao, Juan
    CHEMICAL ENGINEERING JOURNAL, 2020, 400
  • [8] EFFICIENT DEGRADATION OF RECALCITRANT PHARMACEUTICALS BY A NOVEL ELECTRO-FENTON SYSTEM: THE CASE OF DICLOFENAC
    Plakas, K. V.
    Karabelas, A. J.
    Sklari, S. D.
    Zaspalis, V. T.
    PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,
  • [9] Chemically modified graphite felt as an efficient cathode in electro-Fenton for p-nitrophenol degradation
    Zhou, Lei
    Zhou, Minghua
    Hu, Zhongxin
    Bi, Zhaoheng
    Serrano, K. Groenen
    Electrochimica Acta, 2014, 140 : 376 - 383
  • [10] Efficient degradation of contaminants of emerging concerns by a new electro-Fenton process with Ti/MMO cathode
    Yuan, Songhu
    Gou, Na
    Alshawabkeh, Akram N.
    Gu, April Z.
    CHEMOSPHERE, 2013, 93 (11) : 2796 - 2804