Emittance measurements in low energy ion storage rings

被引:2
|
作者
Hunt, J. R. [1 ,2 ]
Carli, C. [3 ]
Resta-Lopez, J. [1 ,2 ]
Welsch, C. P. [1 ,2 ]
机构
[1] Cockcroft Inst, Warrington, Cheshire, England
[2] Univ Liverpool, Liverpool, Merseyside, England
[3] CERN, European Org Nucl Res, Geneva, Switzerland
关键词
Beam dynamics; Low energy storage rings; Antiprotons; Beam diagnostics; Beam scraping; BEAM DYNAMICS;
D O I
10.1016/j.nima.2018.04.018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The development of the next generation of ultra-low energy antiproton and ion facilities requires precise information about the beam emittance to guarantee optimum performance. In the Extra-Low ENergy Antiproton storage ring (ELENA) the transverse emittances will be measured by scraping. However, this diagnostic measurement faces several challenges: non-zero dispersion, non-Gaussian beam distributions due to effects of the electron cooler and various systematic errors such as closed orbit offsets and inaccurate rms momentum spread estimation. In addition, diffusion processes, such as intra-beam scattering might lead to emittance overestimates. Here, we present algorithms to efficiently address the emittance reconstruction in presence of the above effects, and present simulation results for the case of ELENA.
引用
收藏
页码:139 / 151
页数:13
相关论文
共 50 条
  • [41] High-accuracy mass measurements in ion traps and storage rings
    Kluge, H.-J.
    Hyperfine Interactions, 108 (1-3):
  • [42] CRITICAL STUDY OF EMITTANCE MEASUREMENTS OF INTENSE LOW-ENERGY PROTON BEAMS
    EVANS, LR
    WARNER, DJ
    NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (01): : 61 - &
  • [43] Beam emittance measurements on multicusp ion sources
    Sarstedt, M
    Lee, Y
    Leung, KN
    Perkins, LT
    Pickard, DS
    Weber, M
    Williams, MD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03): : 1249 - 1251
  • [44] SOME EMITTANCE MEASUREMENTS WITH A DUOPLASMATRON ION SOURCE
    WROE, H
    NUCLEAR INSTRUMENTS & METHODS, 1967, 52 (01): : 67 - &
  • [45] THE EFFECT OF INTRA-BEAM SCATTERING ON THE DESIGN OF LOW EMITTANCE STORAGE-RINGS FOR FEL OPERATION
    GUIDUCCI, S
    PREGER, MA
    PALUMBO, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 237 (1-2): : 353 - 359
  • [46] Low-emittance tuning of storage rings using normal mode beam position monitor calibration
    Wolski, A.
    Rubin, D.
    Sagan, D.
    Shanks, J.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2011, 14 (07):
  • [47] EMITTANCE MEASUREMENTS ON NEGATIVE-ION SOURCES
    DOUCAS, G
    GREENWAY, TJL
    HYDER, HRM
    KNOX, AB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (02) : 1155 - 1161
  • [48] Possibilities of electron cooling in low energy electrostatic storage rings
    Syresin, E
    Noda, K
    Tanabe, T
    PHYSICA SCRIPTA, 2003, T104 : 185 - 188
  • [50] ANOMALOUS EQUILIBRIUM EMITTANCE DUE TO CHROMATICITY IN ELECTRON STORAGE-RINGS
    OIDE, K
    KOISO, H
    PHYSICAL REVIEW E, 1994, 49 (05): : 4474 - 4479