Numerical studies on the effects of hot end temperature on a single-stage multi-bypass type pulse tube cryocooler

被引:0
|
作者
Liu, S. X. [1 ]
Chen, L. B. [1 ,2 ]
Zhou, Y. [1 ]
Wang, J. J. [1 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
来源
关键词
REFRIGERATORS;
D O I
10.1088/1757-899X/101/1/012032
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of pulse tube cryocooler is affected by the temperature of hot end, which is mainly influenced by the temperature of environment. Effects on a single-stage multi-bypass type pulse tube cryocooler are investigated by means of numerical simulation. For different opening of multi-bypass orifices, the refrigeration performances are studied when hot end temperature changed in a certain range, and some numerical results are provided and analysed. Together with the temperature at cold head and multi-bypass position, the mass flow rate through the multi-bypass orifice is affected significantly by the temperature of hot end, and the optimum opening of multi-bypass orifice decreases with hot end temperature increasing from 240 K to 320 K. Therefore, to select an optimal opening of bypass orifice according to the temperature of operating environment is necessary.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] THEORETICAL AND EXPERIMENTAL INVESTIGATION OF A 4 K SINGLE-STAGE STIRLING TYPE PULSE TUBE CRYOCOOLER WITH PRECOOLING
    Li, Z. P.
    Chen, J.
    Gan, Z. H.
    Qiu, L. M.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 1609 - 1616
  • [22] Studies on a single stage GM type pulse tube cryocooler using an indigenous helium compressor
    Kasthurirengan, S.
    Jacob, S.
    Karunanithi, R.
    Behera, Upendra
    Nadig, D. S.
    Bahuguni, Anand
    ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 253 - 256
  • [23] Investigation of intermediate cooling capacity from a single-stage coaxial pulse tube cryocooler
    Han, Yinan
    Zhang, Ankuo
    Yu, Wenhui
    Xiong, Chao
    APPLIED THERMAL ENGINEERING, 2022, 217
  • [24] 0.2 W@20.6 K single-stage high frequency pulse tube cryocooler
    Chen, Liu-Biao
    Jin, Hai
    Zhu, Wen-Xiu
    Wang, Jun-Jie
    Zhou, Yuan
    Gu, Kai-Xuan
    Ji, Wei
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2013, 34 (04): : 587 - 590
  • [25] Numerical simulation and experimental verification of the oscillating flow in a multi-bypass pulse tube refrigerator with area change
    Ju, YL
    Wang, C
    Zhou, Y
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 1949 - 1955
  • [26] CFD modeling and experimental verification of a single-stage coaxial Stirling-type pulse tube cryocooler without either double-inlet or multi-bypass operating at 30-35 K using mixed stainless steel mesh regenerator matrices
    Dang, Haizheng
    Zhao, Yibo
    CRYOGENICS, 2016, 78 : 40 - 50
  • [27] Operating characteristics of a single-stage Stirling-type pulse tube cryocooler with high cooling power at liquid nitrogen temperatures
    Sun, Jiu-ce
    Dietrich, Marc
    Qiu, Li-min
    Thummes, Guenter
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2015, 16 (07): : 577 - 585
  • [28] EXPERIMENTAL STUDIES ON A SINGLE STAGE STIRLING TYPE PULSE TUBE CRYOCOOLER DRIVEN BY OIL-LUBRICATED COMPRESSOR
    Ren, Jia
    Hu Jianying
    Luo Ercang
    Wang Xiaotao
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 52 - +
  • [29] Research of Stirling-type Multi-bypass Pulse Tube Cryocoolers with Temperatures Below 20 K
    Chen Liubiao
    Zhou Qiang
    Zhu Wenxiu
    Xue Xiaodai
    Wang Junjie
    Zhou Yuan
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 982 - 987
  • [30] Transient analysis of single stage GM type double inlet pulse tube cryocooler
    Gujarati, P. B.
    Desai, K. P.
    Naik, H. B.
    Atrey, M. D.
    ADVANCES IN CRYOGENIC ENGINEERING, 2015, 101