Conformational distribution of surface-adsorbed fibronectin molecules explored by single molecule localization microscopy

被引:11
|
作者
Klotzsch, E. [1 ,2 ]
Schoen, I. [1 ]
Ries, J. [3 ]
Renn, A. [4 ]
Sandoghdar, V. [5 ]
Vogel, V. [1 ]
机构
[1] ETH, Dept Hlth Sci & Technol, Lab Appl Mechanobiol, Zurich, Switzerland
[2] Vienna Univ Technol, Inst Appl Phys, A-1040 Vienna, Austria
[3] EMBL, Heidelberg, Germany
[4] ETH, Phys Chem Lab, Zurich, Switzerland
[5] Max Planck Inst Sci Light, Erlangen, Germany
基金
欧洲研究理事会;
关键词
SUPERRESOLUTION MICROSCOPY; HYDROPHOBIC SURFACES; BACTERIAL ADHESINS; FLUORESCENCE; BINDING; ADSORPTION; PROTEINS; MONOLAYERS; DOMAINS; SILICA;
D O I
10.1039/c3bm60262a
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Adsorbed proteins that promote cell adhesion mediate the response of cells to biomaterials and scaffolds. As proteins undergo conformational changes upon surface adsorption, their functional display may be significantly affected by surface chemistry or solution conditions during the adsorption process. A high-resolution localization microscopy technique is extended here to probe the conformation of individual fibronectin (Fn) molecules at the glass-water interface under physiological buffer conditions. To map distances, four available cysteines located on the modules FnIII(7) and FnIII(15) of dimeric Fn were site-specifically labeled with Cy3B, and their relative positions were determined by stepwise photobleaching with nanometer precision. The four labels on single Fn molecules did not show a uniform or linear arrangement. The distances between label positions were distributed asymmetrically around 33 nm with a tail towards higher distances. Exposure of Fn to denaturing solution conditions during adsorption increased the average distances up to 43 nm for 4 M guanidinium HCl, while changing the solution conditions after the adsorption had no effect, indicating that the observed intra-molecular distances are locked-in during the adsorption process. Also surface coatings of different hydrophobicity altered the conformational distribution, shifting label distances from a median of 24 nm on hydrophilic to 49 nm on hydrophobic surfaces. These results further highlight that the conformation of macromolecules at interfaces depends on the adsorption history. While illustrated here for surface adsorbed Fn, the power of localization-based microscopy extends the repertoire of techniques to characterize biomolecules at interfaces.
引用
收藏
页码:883 / 892
页数:10
相关论文
共 50 条
  • [31] Ultra-sensitive fluorescence spectroscopy of isolated surface-adsorbed molecules using an optical nanofiber
    Stiebeiner, A.
    Rehband, O.
    Garcia-Fernandez, R.
    Rauschenbeutel, A.
    OPTICS EXPRESS, 2009, 17 (24): : 21704 - 21711
  • [32] Artifacts in single-molecule localization microscopy
    Burgert, Anne
    Letschert, Sebastian
    Doose, Soeren
    Sauer, Markus
    HISTOCHEMISTRY AND CELL BIOLOGY, 2015, 144 (02) : 123 - 131
  • [33] Fluorophores for single-molecule localization microscopy
    Klementieva, N. V.
    Bozhanova, N. G.
    Zagaynova, E. V.
    Lukyanov, K. A.
    Mishin, A. S.
    RUSSIAN JOURNAL OF BIOORGANIC CHEMISTRY, 2017, 43 (03) : 227 - 234
  • [34] Challenges in quantitative single molecule localization microscopy
    Shivanandan, A.
    Deschout, H.
    Scarselli, M.
    Radenovic, A.
    FEBS LETTERS, 2014, 588 (19) : 3595 - 3602
  • [35] Single-molecule labeling and localization microscopy
    Hu, Ying S.
    BIOPHYSICAL JOURNAL, 2024, 123 (03) : 29A - 29A
  • [36] Quantitative Single-Molecule Localization Microscopy
    Hugelier, Siewert
    Colosi, P. L.
    Lakadamyali, Melike
    ANNUAL REVIEW OF BIOPHYSICS, 2023, 52 : 139 - 160
  • [37] Artifacts in single-molecule localization microscopy
    Anne Burgert
    Sebastian Letschert
    Sören Doose
    Markus Sauer
    Histochemistry and Cell Biology, 2015, 144 : 123 - 131
  • [38] Review and Prospect for Single Molecule Localization Microscopy
    Li Yuzhu
    Li Chuankang
    Hao Xiang
    Liu Xu
    Kuang Cuifang
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (24)
  • [39] Localization accuracy in single-molecule microscopy
    Ober, RJ
    Ram, S
    Ward, ES
    BIOPHYSICAL JOURNAL, 2004, 86 (02) : 1185 - 1200
  • [40] Wavelet analysis for single molecule localization microscopy
    Izeddin, I.
    Boulanger, J.
    Racine, V.
    Specht, C. G.
    Kechkar, A.
    Nair, D.
    Triller, A.
    Choquet, D.
    Dahan, M.
    Sibarita, J. B.
    OPTICS EXPRESS, 2012, 20 (03): : 2081 - 2095