SNR measurements of silicon photomultipliers in the continuous wave regime

被引:2
|
作者
Adamo, G. [1 ]
Agro, D. [1 ]
Stivala, S. [1 ]
Parisi, A. [1 ]
Giaconia, C. [1 ]
Busacca, A. C. [1 ]
Fallica, G. [2 ]
机构
[1] Univ Palermo, DEIM, Viale Sci,Bldg 9, I-90128 Palermo, Italy
[2] STMicroelect, R&D, IMS, I-95121 Catania, Italy
来源
SILICON PHOTONICS IX | 2014年 / 8990卷
关键词
signal-to-noise ratio; SNR; SiPM; continuous wave; shot noise; dark current; DETECTION EFFICIENCY; RESPONSIVITY;
D O I
10.1117/12.2039720
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We report on our Signal-to-Noise Ratio (SNR) measurements carried out, in the continuous wave regime, at different frequencies and at various temperatures, on a novel class of silicon photomultipliers (SiPMs) fabricated in planar technology on silicon p-type substrate. SNR of SiPMs is given by the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square (RMS) deviation of the same current. In our measurements, we have employed a 10 Hz equivalent noise bandwidth, around the lock-in amplifier reference frequency. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current, while background light is not present in our setup. We have found that the SNR is independent from frequency in the evaluated range 1 - 100 kHz. Our measurements highlight a quasi-flat trend of the SiPM SNR up to an overvoltage of about 5 V (with respect to the breakdown voltage of 28.0 V). At higher overvoltages (OV), we have observed a SNR decrease, mainly because of the strong increase of the shot noise. We have also performed a comparison between the SiPM and the PhotoMultiplier Tube (PMT) SNR as a function of the temperature of the SiPM package and at different bias voltages. Our results show the outstanding performance of this novel class of SiPMs even without the need of any cooling system. Indeed, their SNR is only a few dBs below the PMT SNR at room temperature. Furthermore, cooling the SiPM at a package cell temperature of 3 degrees C, it reaches the PMT SNR values at room temperature despite the SiPM is biased in the range 28.7 - 33.5 V, while the PMT has a bias value up to 950 V.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Measurements of Silicon Photomultipliers Responsivity in Continuous Wave Regime
    Adamo, Gabriele
    Agro, Diego
    Stivala, Salvatore
    Parisi, Antonino
    Giaconia, Giuseppe Costantino
    Busacca, Alessandro
    Mazzillo, Massimo
    Sanfilippo, Delfo
    Fallica, Giorgio
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 2013, 60 (11) : 3718 - 3725
  • [2] Silicon Photomultipliers Signal-to-Noise Ratio in the Continuous Wave Regime
    Adamo, Gabriele
    Parisi, Antonino
    Stivala, Salvatore
    Tomasino, Alessandro
    Agro, Diego
    Curcio, Luciano
    Giaconia, Giuseppe Costantino
    Busacca, Alessandro
    Fallica, Giorgio
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2014, 20 (06) : 284 - 290
  • [3] Signal to Noise Ratio of Silicon Photomultipliers measured in the Continuous Wave Regime
    Adamo, Gabriele
    Agro, Diego
    Stivala, Salvatore
    Parisi, Antonino
    Tomasino, Alessandro
    Curcio, Luciano
    Pernice, Riccardo
    Giaconia, Costantino
    Busacca, Alessandro C.
    Fallica, Giorgio
    [J]. 2014 THIRD MEDITERRANEAN PHOTONICS CONFERENCE, 2014,
  • [4] Responsivity measurements of N-on-P and P-on-N silicon photomultipliers in the continuous wave regime
    Adamo, Gabriele
    Agro, Diego
    Stivala, Salvatore
    Parisi, Antonino
    Giaconia, Costantino
    Busacca, Alessandro
    Mazzillo, Massimo C.
    Sanfilippo, Delfo
    Fallica, Pier Giorgio
    [J]. SILICON PHOTONICS VIII, 2013, 8629
  • [5] A comprehensive circuit model for evaluating the response of silicon photomultipliers in continuous wave light regime
    Siminfar, Amir Reza
    Shoaei, Omid
    [J]. INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2019, 47 (10) : 1585 - 1602
  • [6] Conditional Measurements with Silicon Photomultipliers
    Chesi, Giovanni
    Allevi, Alessia
    Bondani, Maria
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (10):
  • [7] On the use of silicon photomultipliers for thermoluminescence measurements
    Kim, Hyoungtaek
    Lim, Kyung Taek
    Lee, Jungil
    Cho, Gyuseong
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 182
  • [8] The new versatile general purpose surface-muon instrument (GPS) based on silicon photomultipliers for μSR measurements on a continuous-wave beam
    Amato, A.
    Luetkens, H.
    Sedlak, K.
    Stoykov, A.
    Scheuermann, R.
    Elender, M.
    Raselli, A.
    Graf, D.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (09):
  • [9] Photocounting measurements with dead time and afterpulses in the continuous-wave regime
    Semenov, A. A.
    Samelin, J.
    Boldt, Ch.
    Schuenemann, M.
    Reiher, C.
    Vogel, W.
    Hage, B.
    [J]. PHYSICAL REVIEW A, 2024, 109 (01)
  • [10] Microflow Measurements of Antibodies Fluorescence Using Silicon Photomultipliers
    Dorosz, P.
    Baszczyk, M.
    Glab, S.
    Kucewicz, W.
    Mik, L.
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,