Non-invasive evaluation of hair interior morphology by X-ray microscope

被引:4
|
作者
Kim, Beom Joon
Kwon, Oh Sang
Park, Won Seok
Youn, Hwa Shik
Choi, Chong Won
Kim, Kyu Han
Eun, Hee Chul
机构
[1] Seoul Natl Univ, Coll Med, Dept Dermatol, Seoul 110744, South Korea
[2] Amore Pacific R&D Ctr, Skin Res Inst, Gyeonggi Do, South Korea
[3] Pohang Univ Sci & Technol, Pohang Accelerator Lab, Pohang, South Korea
来源
JOURNAL OF DERMATOLOGY | 2006年 / 33卷 / 11期
关键词
electron microscopy; hair;
D O I
10.1111/j.1346-8138.2006.00177.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Lots of trials have been performed to obtain better microscopic images of hair structure. Although scanning electron microscopy (SEM) and transmission electron microscopy (TEM) provide detailed images of hair, artificial processing may modify the original images during sample preparation. To overcome this limitation, we applied newly-developed X-ray microscopy with an 80-100 nm spatial resolution to produce a detailed view of the morphological change of hair interior. This X-ray microscopy permits us to penetrate a hair shaft without any artificial change and also provides precise images of hair interior with fine resolution. We evaluated the interior morphological change of Japanese standard hair tress No. 8 by various treatments such as ultraviolet (UV) irradiation, heating, hair dyeing, decolorizing bleaching agents and permanent waving. Internal morphological images were relatively similar in both heated and UV-irradiated hair. They revealed coarsening of cuticles and dehydration of cortex and medulla. When compared with TEM, X-ray microscopy provides more intact images in the cuticle and may be a useful tool in observing fine cracks of hair cortex. Additionally, X-ray images were intact and not influenced by any processing procedures. In observing the external and internal structure of hair, its resolution seems to be somewhat lesser than TEM and there are also several remaining weaknesses to be improved. Hopefully, forthcoming technology will solve these problems in the near future.
引用
收藏
页码:759 / 764
页数:6
相关论文
共 50 条
  • [21] Non-Invasive Imaging of Regional Lung Function using X-Ray Computed Tomography
    Brett A. Simon
    Journal of Clinical Monitoring and Computing, 2000, 16 : 433 - 442
  • [22] X-ray computed tomography: A novel non-invasive approach for the detection of microplastics in sediments?
    Trusler, Megan M.
    Sturrock, Craig J.
    Vane, Christopher H.
    Cook, Sarah
    Lomax, Barry H.
    MARINE POLLUTION BULLETIN, 2023, 194
  • [23] X-ray imaging as a time-saving, non-invasive technique for diet analysis
    Beckmann, Melanie C.
    Gilliam, James F.
    Langerhans, R. Brian
    FISHERIES RESEARCH, 2015, 161 : 1 - 7
  • [24] Combined Neutron and X-ray imaging for non-invasive investigations of cultural heritage objects
    Mannes, D.
    Schmid, F.
    Frey, J.
    Schmidt-Ott, K.
    Lehmann, E.
    PROCEEDINGS OF THE 10TH WORLD CONFERENCE ON NEUTRON RADIOGRAPHY (WCNR-10), 2015, 69 : 653 - 660
  • [25] Non-invasive imaging of regional lung function using X-ray computed tomography
    Simon, BA
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2000, 16 (5-6) : 433 - 442
  • [26] A non-invasive computer aided diagnosis of osteoarthritis from digital x-ray images
    Subramoniam, M.
    Barani, S.
    Rajini, V
    BIOMEDICAL RESEARCH-INDIA, 2015, 26 (04): : 721 - 729
  • [27] Non-invasive assessment of the formation of tourmaline nodules by X-ray microtomography and computer modeling
    Valentini, Luca
    Marchesini, Barbara
    Parisatto, Matteo
    Perugini, Diego
    Artioli, Gilberto
    AMERICAN MINERALOGIST, 2015, 100 (2-3) : 459 - 465
  • [28] INDICATION AND INFORMATION OF NON-INVASIVE X-RAY EXAMINATIONS OF THORACIC ORGANS IN CASE OF A HYPERTONIA
    COBET, H
    RICHTER, K
    HEMPEL, WE
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1977, 32 (41): : 1924 - 1928
  • [29] Development of an X-ray computed tomography system for non-invasive imaging of industrial materials
    Abdullah, J.
    Sipaun, S. M.
    Said, M. K. M.
    Mohamad, G. H. P.
    Ibrahim, M. M.
    Mustapha, I.
    Zain, R. M.
    Rahman, M. F. A.
    Mustapha, M.
    Shaari, M. R.
    Hassan, H.
    CURRENT ISSUES OF PHYSICS IN MALAYSIA, 2008, 1017 : 408 - +
  • [30] Use of non-invasive X-ray microtomography for characterizing microstructure of extruded biopolymer foams
    Trater, AM
    Alavi, S
    Rizvi, SSH
    FOOD RESEARCH INTERNATIONAL, 2005, 38 (06) : 709 - 719