Integrated Pulmonary Index (IPI) monitorization under sedation in cataract surgery with phacoemulsification technique

被引:7
|
作者
Ar, Arzu Yildirim [1 ]
Abitagaoglu, Suheyla [1 ]
Turan, Guldem [1 ]
Karip, Ceren Sanli [1 ]
Akgun, Nur [1 ]
Boybeyi, Doga Meric [1 ]
Ari, Dilek Erdogan [1 ]
机构
[1] Fatih Sultan Mehmet Educ & Res Hosp, Anesthesiol & Reanimat Dept, 1 Seker Evler Sit,B Blok,D 25, Istanbul, Turkey
关键词
Sedation; Hypoxemia; Hypoventilation; Monitoring; Phacoemulsification; ANESTHESIA; ENDOSCOPY; EVENTS;
D O I
10.1007/s10792-018-1024-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose We aimed to investigate that change of IPI values after sedation of patients undergoing cataract surgery under sedation. Methods We included 50 patients (ASA I-III) undergoing cataract surgery under sedation by phacoemulsification method in this prospective observational study. IPI, SpO(2), ETCO2, respiratory rate (RR), peripheral pulse rate (PR), hemodynamic data and BIS values and perioperative complications were recorded. Results Compared to baseline values, RR value at 5th min, RR, PR, IPI values at 10th min and RR, PR values at 15th min were significantly low and heart rate value at 15th min and arterial pressure, bispectral index (BIS) values at 5th min, 10th min, 15th min, 20th min, 25th min and 30th min were lower than baseline values. Conclusions IPI monitoring will provide guidance during sedation of patients with comorbid diseases undergoing cataract surgery by phacoemulsification method.
引用
下载
收藏
页码:1949 / 1954
页数:6
相关论文
共 50 条
  • [11] Visual perception during phacoemulsification cataract surgery under subtenons anaesthesia
    S S Wickremasinghe
    P G Tranos
    N Sinclair
    P S Andreou
    M L Harris
    B C Little
    Eye, 2003, 17 : 501 - 505
  • [12] Dexmedetomidine sedation during cataract surgery under regional anaesthesia
    Ayoglu, H.
    Altunkaya, H.
    Ozer, Y.
    Yapakci, O.
    Ozkocak, I.
    Oz, O.
    Alpay, A.
    Ugurbas, S. H.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (03) : 448 - 448
  • [13] Visual experience during phacoemulsification cataract surgery under topical anaesthesia
    Newman, DK
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (01) : 13 - 15
  • [14] Use of the Integrated Pulmonary Index (IPI) to Predict Respiratory Compromise in a Trauma Population
    Pelaez, C.
    Spilman, S. K.
    Lamb, K. D.
    Oetting, T. W.
    Fuchsen, E. A.
    Olson, S. D.
    Sahr, S. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [15] Visual perception during phacoemulsification cataract surgery under topical and regional anaesthesia
    Tranos, PG
    Wickremasinghe, SS
    Sinclair, N
    Foster, PJ
    Asaria, R
    Harris, ML
    Little, BC
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2003, 81 (02): : 118 - 122
  • [16] Comparison of dexmedetomidine and midazolam sedation for cataract surgery under topical anesthesia
    Muttu, S
    Liu, EHC
    Ang, SBL
    Chew, PTK
    Lee, TL
    Ti, LK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09): : 1845 - 1846
  • [17] Cataract surgery using the bimanual phacoemulsification technique with an Accurus system and Mackool microphaco tip
    Tanaka, Takao
    Koshika, Satomi
    Usui, Masahiko
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (10): : 1770 - 1774
  • [18] Modified manual small incision cataract surgery technique for phacoemulsification-trained surgeons
    Ting, Darren S. J.
    Chua, Daniel
    May, Khin Oo
    Aung, Mya
    Kumar, Ashish
    Farook, Mohamed
    Htoon, Hla M.
    Sng, Chelvin C. A.
    Ang, Marcus
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2020, 12
  • [19] RETRACTED: The Technique of Phacoemulsification and Intraocular Lens Implantation in Subluxated Cataract Surgery (Retracted Article)
    Jiang, Huaiyan
    Fu, Wenzhong
    Xu, Hongxia
    STEM CELLS INTERNATIONAL, 2022, 2022
  • [20] Smart respiratory monitoring: clinical development and validation of the IPI™ (Integrated Pulmonary Index) algorithm
    Ronen, M.
    Weissbrod, R.
    Overdyk, F. J.
    Ajizian, S.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (02) : 435 - 442