Glucose challenge test screening for prediabetes and undiagnosed diabetes

被引:48
|
作者
Phillips, L. S. [1 ,2 ]
Ziemer, D. C. [1 ]
Kolm, P. [3 ]
Weintraub, W. S. [3 ]
Vaccarino, V. [4 ]
Rhee, M. K. [1 ]
Chatterjee, R. [5 ]
Narayan, K. M. V. [5 ,6 ]
Koch, D. D. [7 ]
机构
[1] Emory Univ, Sch Med, Div Endocrinol & Metab, Atlanta, GA 30322 USA
[2] Vet Adm Med Ctr, Decatur, GA USA
[3] Christiana Care Hlth Syst, Newark, DE USA
[4] Emory Univ, Sch Med, Div Cardiol, Atlanta, GA 30322 USA
[5] Emory Univ, Rollins Sch Publ Heath, Hubert Dept Global Hlth, Atlanta, GA 30322 USA
[6] Emory Univ, Sch Med, Dept Med, Atlanta, GA 30322 USA
[7] Emory Univ, Sch Med, Dept Pathol & Lab Med, Atlanta, GA 30322 USA
关键词
Glucose challenge; Natural history; Prediabetes; Preventive management; Screening; Type; 2; diabetes; CARDIOVASCULAR-DISEASE RISK; PLASMA-GLUCOSE; US POPULATION; COST-EFFECTIVENESS; GLYCATED HEMOGLOBIN; METABOLIC SYNDROME; AFRICAN-AMERICANS; UNITED-STATES; TYPE-2; MELLITUS;
D O I
10.1007/s00125-009-1407-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Diabetes prevention and care are limited by lack of screening. We hypothesised that screening could be done with a strategy similar to that used near-universally for gestational diabetes, i.e. a 50 g oral glucose challenge test (GCT) performed at any time of day, regardless of meal status, with one 1 h sample. At a first visit, participants had random plasma and capillary glucose measured, followed by the GCT with plasma and capillary glucose (GCTplasma and GCTcap, respectively). At a second visit, participants had HbA(1c) measured and a diagnostic 75 g OGTT. The 1,573 participants had mean age of 48 years, BMI 30.3 kg/m(2) and 58% were women and 58% were black. Diabetes (defined by WHO) was present in 4.6% and prediabetes (defined as impaired glucose tolerance [2 h glucose 7.8-11.1 (140-199 mg/dl) with fasting glucose a parts per thousand currency sign6.9 (125 mg/dl)] and/or impaired fasting glucose with plasma glucose 6.1-6.9 mmol/l [110-125 mg/dl]) in 18.7%. The GCTplasma provided areas under the receiver-operating-characteristic curves of 0.90, 0.82 and 0.79 for detection of diabetes, diabetes or prediabetes, and prediabetes, respectively, all of which were higher than GCTcap, random and capillary glucose, and HbA(1c) (p < 0.02 for all). The performance of GCTplasma was unaffected by time after meals or time of day, and was better in blacks than whites, but otherwise comparable in men and women, and in groups with differing prevalence of glucose intolerance. GCTplasma screening would cost approximately US$84 to identify one person with previously unrecognised diabetes or prediabetes. GCT screening for prediabetes and previously unrecognised diabetes would be accurate, convenient and inexpensive. Widespread use of GCT screening could help improve disease management by permitting early initiation of therapy aimed at preventing or delaying the development of diabetes and its complications.
引用
收藏
页码:1798 / 1807
页数:10
相关论文
共 50 条
  • [21] Fasting plasma glucose versus glucose challenge test: screening for gestational diabetes and cost effectiveness
    Rey, E
    Hudon, L
    Michon, N
    Boucher, P
    Ethier, J
    Saint-Louis, P
    CLINICAL BIOCHEMISTRY, 2004, 37 (09) : 780 - 784
  • [22] Glucose challenge test: Screening threshold for gestational diabetes mellitus and associated outcomes
    Cheng, Yvonne W.
    McLaughlin, G. Blake
    Esakoff, Tania F.
    Block-Kurbisch, Ingrid
    Caughey, Aaron B.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2007, 20 (12): : 903 - 908
  • [23] THE EFFECTIVENESS OF 50 GRAM ORAL GLUCOSE CHALLENGE TEST IN GESTATIONAL DIABETES SCREENING
    Sagun, Murat
    Tosun, Migraci
    Malatyalioglu, Erdal
    Centinkaya, Mehmet Bilge
    Alper, Tayfun
    Kokcu, Arif
    TURKISH JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2008, 5 (04) : 258 - 262
  • [24] 50 Grams Oral Glucose Challenge Test: Is It an Effective Screening Test for Gestational Diabetes Mellitus?
    Abu-Heija A.
    Al-Bash M.
    Ishrat N.
    Al-Kharausi L.
    The Journal of Obstetrics and Gynecology of India, 2016, 66 (Suppl 1) : 7 - 11
  • [25] The capillary oral glucose tolerance test: A useful screening tool for diabetes and prediabetes in an underserved Latino population
    Baginsky, P
    Steindler, J
    DIABETES, 2005, 54 : A295 - A295
  • [26] A Chinese Diabetes Risk Score for Screening of Undiagnosed Diabetes and Abnormal Glucose Tolerance
    Liu, Min
    Pan, Changyu
    Jin, Mengmeng
    DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (05) : 501 - 507
  • [27] Accuracy of capillary blood glucose for 50-g glucose challenge test for gestational diabetes screening
    Dittakarn Boriboonhirunsarn
    Amporn Robkhonburi
    Maria Asad-dehghan
    Diabetology International, 2022, 13 : 561 - 565
  • [28] Accuracy of capillary blood glucose for 50-g glucose challenge test for gestational diabetes screening
    Boriboonhirunsarn, Dittakarn
    Robkhonburi, Amporn
    Asad-dehghan, Maria
    DIABETOLOGY INTERNATIONAL, 2022, 13 (03) : 561 - 565
  • [29] Screening for Gestational Diabetes-Oral Glucose Challenge Test vs. Fasting Plasma Glucose
    Sanu, Olaleye
    Kalu, Gregory
    DIABETES, 2014, 63 : A343 - A343
  • [30] Abnormal screening glucose challenge test in pregnancy and future risk of diabetes in young women
    Retnakaran, R.
    Shah, B. R.
    DIABETIC MEDICINE, 2009, 26 (05) : 474 - 477