Cardiac real-time imaging using SENSE

被引:0
|
作者
Weiger, M
Pruessmann, KP
Boesiger, P
机构
[1] Univ Zurich, Inst Biomed Engn & Med Informat, CH-8092 Zurich, Switzerland
[2] ETH Zurich, CH-8092 Zurich, Switzerland
关键词
MRI; real-time imaging; cardiac imaging; sensitivity encoding; SENSE;
D O I
10.1002/(SICI)1522-2594(200002)43:2<177::AID-MRM3>3.0.CO;2-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest as well asunder physiological stress. Sample images are presented with scan times per image down to 13 msec at a spatial resolution of 4.1 mm, and 27 msec at a resolution of 2.6 mm. Moreover, multiple slice real-time imaging is demonstrated at a rate of 38 double-frames per second. (C) 2000 Wiley-Liss, Inc.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 50 条
  • [21] Real-time stress assessment using thermal imaging
    Hong, Kan
    Hong, Sheng
    VISUAL COMPUTER, 2016, 32 (11): : 1369 - 1377
  • [22] Real-time Burn Classification using Ultrasound Imaging
    Sangrock Lee
    Hanglin Rahul
    Deepak Ye
    Uwe Chittajallu
    Tatiana Kruger
    James K. Boyko
    Andinet Lukan
    Jack Enquobahrie
    Suvranu Norfleet
    Scientific Reports, 10
  • [23] Real-time dosimetry method using an imaging plate
    Sakasai, K
    Katagiri, M
    Kishimoto, M
    Fujii, Y
    REACTOR DOSIMETRY: RADIATION METROLOGY AND ASSESSMENT, 2001, 1398 : 775 - 780
  • [24] Comparison of real-time imaging cardiac magnetic resonance for left ventricular volumes with conventional imaging in patients with atrial fibrillation: Is real-time required?
    Costa, SP
    Yeon, SB
    Kissinger, KV
    Chuang, MC
    Manning, WJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 436A - 437A
  • [25] REAL-TIME MOVIE IMAGING FROM A SINGLE CARDIAC CYCLE BY NMR
    CHAPMAN, B
    TURNER, R
    ORDIDGE, RJ
    DOYLE, M
    CAWLEY, M
    COXON, R
    GLOVER, P
    MANSFIELD, P
    MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) : 246 - 254
  • [26] Sliding window reduced FOV reconstruction for real-time cardiac imaging
    Metze, Patrick
    Li, Hao
    Speidel, Tobias
    Buckert, Dominik
    Rottbauer, Wolfgang
    Rasche, Volker
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (03): : 236 - 244
  • [27] Real-time imaging of cAMP dynamics in an in vitro model of cardiac hypertrophy
    Zoccarato, A.
    Zaccolo, M.
    EUROPEAN HEART JOURNAL, 2011, 32 : 635 - 635
  • [28] Real-time imaging of cAMP dynamics in an in vitro model of cardiac hypertrophy
    Zoccarato, A.
    Zaccolo, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183 : 635 - 635
  • [29] Implementing Capon Beamforming on a GPU for Real-Time Cardiac Ultrasound Imaging
    Asen, Jon Petter
    Buskenes, Jo Inge
    Nilsen, Carl-Inge Colombo
    Austeng, Andreas
    Holm, Sverre
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (01) : 76 - 85
  • [30] CARDIAC IMAGING WITH A REAL-TIME ULTRASONIC SCANNER OF A ROTATING TRANSDUCER DESIGN
    BOW, CR
    MCDICKEN, WN
    ANDERSON, T
    SCORGIE, RE
    SAPRU, RS
    MUIR, AL
    BRITISH JOURNAL OF RADIOLOGY, 1978, 51 (608): : 645 - 645