Ion-Trap-Performance Enhancement Utilizing Pulsed Buffer-Gas Introduction

被引:5
|
作者
Vazquez, Timothy [1 ]
Taylor, Colette [1 ]
Evans-Nguyen, Theresa [1 ]
机构
[1] Univ S Florida, Dept Chem, 4202 East Fowler Ave, Tampa, FL 33620 USA
关键词
COLLISION-INDUCED DISSOCIATION; MASS-SPECTROMETER; RESONANCE EXCITATION; ORGANIC-COMPOUNDS; ACTIVATION; EJECTION; HELIUM; SHIFTS; TIME; AIR;
D O I
10.1021/acs.analchem.8b02881
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel means of improving the resolution and total ion signal inside a digitally driven 3D quadrupole ion trap has been studied. Conventional ion-trapping methods occur by injecting helium gas continuously into the trap to kinetically cool ions and improve trapping efficiency. Utilizing a pulsed helium introduction allows for trapping aided by collisional cooling while mitigating ion losses due to gas collisions during ion scan-out. Operating the trap in resonance-ejection mode, we demonstrate that pulsed helium introduction improves the resolution by a factor of similar to 2 and that resolution is retained as the total ion signal increases. We also show that ejections at other harmonic secular frequencies under static helium conditions no longer occur during pulsed helium introduction. Improving timing synchronization can lead to the determination of the optimal conditions needed to maximize signal intensity as well as ion ejection.
引用
收藏
页码:10600 / 10606
页数:7
相关论文
共 50 条
  • [31] Enhanced performance of elemental copper-vapor lasers by use of H2-HCl-Ne buffer-gas mixtures
    Withford, MJ
    Brown, DJW
    Carman, RJ
    Piper, JA
    OPTICS LETTERS, 1998, 23 (09) : 706 - 708
  • [32] MS/MS of Ions in a Low Pressure Linear Ion Trap using a Pulsed Gas
    Collings, Bruce A.
    Romaschin, Matthew A.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (09) : 1714 - 1717
  • [33] Application of Pulsed Buffer Gas Jets for the Signal Enhancement of Laser-Induced Breakdown Spectroscopy
    Son, Joon Gon
    Choi, Sung-Chul
    Oh, Myoung-Kyu
    Kang, Hoonsoo
    Suk, Hyyong
    Lee, Yonghoon
    APPLIED SPECTROSCOPY, 2010, 64 (11) : 1289 - 1297
  • [34] INTERNAL PULSED VALVE SAMPLE INTRODUCTION ON A QUADRUPOLE ION-TRAP MASS-SPECTROMETER
    COOPERSMITH, BI
    YOST, RA
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (10) : 976 - 980
  • [35] Enhanced performance of elemental copper-vapor lasers by use of H2-HCl-Ne buffer-gas mixtures
    Centre for Lasers and Applications, Macquarie University, Sydney, NSW 2109, Australia
    Opt. Lett., 9 (706-708):
  • [36] EFFECT OF BUFFER GAS ON THE TOTAL NUMBER AND THE STORAGE TIME OF BA IONS TRAPPED IN A RF ION TRAP
    YODA, J
    SUGIYAMA, K
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1989, 38 (02) : 521 - 523
  • [37] EXTERNAL-ION ACCUMULATION IN A PENNING TRAP WITH QUADRUPOLE EXCITATION ASSISTED BUFFER GAS-COOLING
    HASSE, HU
    BECKER, S
    DIETRICH, G
    KLISCH, N
    KLUGE, HJ
    LINDINGER, M
    LUTZENKIRCHEN, K
    SCHWEIKHARD, L
    ZIEGLER, J
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 132 (03): : 181 - 191
  • [38] Design and performance of gas chromatography-rectangular ion trap mass spectrometer
    Huang Ze-Jian
    Gang, Bai
    You, Jiang
    Zhang Xiao-Hua
    Xiong Xing-Chuang
    Xiang, Fang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (03) : 413 - 418
  • [39] Simulation of the collisional cooling effect for binary and ternary buffer gas mixtures in a quadrupole ion trap mass spectrometer
    Wu, HF
    Chen, LW
    Wang, JC
    Lin, YP
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2001, 7 (01) : 1 - 6
  • [40] Experimental investigation into the performance of ion traps using air versus helium as the buffer gas
    Lammert, SA
    Wells, JM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (03) : 361 - 371