A generalized parameterization of T1 motion and its application to the synthesis of planar mechanisms

被引:11
|
作者
Goehler, CM [1 ]
Stanisic, MM [1 ]
Perez, VM [1 ]
机构
[1] Univ Notre Dame, Dept Aerosp & Mech Engn, Notre Dame, IN 46556 USA
关键词
D O I
10.1016/j.mechmachtheory.2004.01.004
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Prior development of T-1 motion theory has used a second-order parameterization which maximally simplifies the theory and allows for a description of the kinematic geometry. In the T-1 motion theory presented here, this parameterization is generalized and not limited to the second-order. The results of this generalized parameterization are more algebraically complex; however, a purely algebraic application of the theory to the motion synthesis problem is made possible without an a-priori recognition of the kinematic geometry. Examples of the synthesis of a four-bar mechanism for rigid-body guidance and a four-bar mechanism for function generation are presented. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1223 / 1244
页数:22
相关论文
共 50 条
  • [31] Testing of UltraSPARC T1 microprocessor and its challenges
    Tan, P. J.
    Le, Tung
    Ng, Keng-Hian
    Mantri, Prasad
    Westfall, James
    2006 IEEE INTERNATIONAL TEST CONFERENCE, VOLS 1 AND 2, 2006, : 464 - +
  • [32] STRONGLY γ-GENERALIZED CLOSED SETS AND STRONGLY γ-T1/2 SPACES
    El-Maghrabi, A. I.
    INFORMATION-AN INTERNATIONAL INTERDISCIPLINARY JOURNAL, 2009, 12 (03): : 473 - 484
  • [33] SYNTHESIS OF A BACTERIAL GALACTOFURANAN, THE COMPONENT OF T1 LIPOPOLYSACCHARIDE
    NEPOGODEV, SA
    BACKINOWSKY, LV
    KOCHETKOV, NK
    BIOORGANICHESKAYA KHIMIYA, 1989, 15 (11): : 1555 - 1560
  • [34] SYNTHESIS OF 3'-5' DINCULEOTIDES WITH RNASE T1
    ROWE, MJ
    SMITH, MA
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1970, 38 (03) : 393 - &
  • [35] Fast myocardial T1 mapping using cardiac motion correction
    Becker, Kirsten M.
    Blaszczyk, Edyta
    Funk, Stephanie
    Nuesslein, Andre
    Schulz-Menger, Jeanette
    Schaeffter, Tobias
    Kolbitsch, Christoph
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) : 438 - 451
  • [36] The effect of motion correction interpolation on quantitative T1 mapping with MRI
    Nachmani, Amitay
    Schurr, Roey
    Joskowicz, Leo
    Mezer, Aviv A.
    MEDICAL IMAGE ANALYSIS, 2019, 52 : 119 - 127
  • [37] T1ρ relaxation time of the meniscus and its relationship with T1ρ of adjacent cartilage in knees with acute ACL injuries at 3 T
    Bolbos, R. I.
    Link, T. M.
    Ma, C. Benjamin
    Majumdar, S.
    Li, X.
    OSTEOARTHRITIS AND CARTILAGE, 2009, 17 (01) : 12 - 18
  • [38] Kinematic mapping application to approximate type and dimension synthesis of planar mechanisms
    Hayes, MJD
    Luu, T
    Chang, XW
    ON ADVANCES IN ROBOT KINEMATICS, 2004, : 41 - 48
  • [39] Type Synthesis of 2T1R Planar Parallel Mechanisms and Their Moduling Development Applications
    Zhang, Dongsheng
    Zheng, Yu
    Wei, Lei
    Wu, Jing
    Xu, Yundou
    Zhao, Yongsheng
    IEEE ACCESS, 2021, 9 : 72217 - 72227
  • [40] NOISE SUPPRESSED LEADING EDGE TRIGGER TECHNIQUE AND ITS APPLICATION TO NAI(T1) PULSE TIMING
    CHO, ZH
    BESHAI, S
    BECKER, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (01) : 199 - 203