Influence of gas flow rate on oxygen flux measurements for dense oxygen conducting ceramic membranes

被引:24
|
作者
Stephens, WT
Mazanec, TJ
Anderson, HU
机构
[1] BP Chem Inc, Cleveland, OH 44128 USA
[2] Univ Missouri, Dept Ceram Engn, Rolla, MO 65401 USA
关键词
electropox; ceramic membrane; mixed ionic-electronic conductor; oxygen transport; oxygen flux measurement;
D O I
10.1016/S0167-2738(99)00332-X
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Oxygen transport through a dense oxygen conducting ceramic membrane is driven by an oxygen activity gradient imposed by the gas streams on either side of the membrane. The oxygen activity on each side of the membrane is altered as oxygen is transported across the membrane. Thus, the oxygen activity gradient will not be the same in each region of a membrane and will generate a different oxygen Aux. This interaction between the oxygen gradient and the oxygen flux can produce a lower average oxygen Bur across the membrane, can mask differences between materials, and can explain the dependence of oxygen flux on oxygen activity. An oxygen flux model has been developed that takes into account the rate of oxygen transport across the membrane, the reducing gas flow rate and the reducing gas composition when determining the oxygen activity gradient imposed on the membrane. The model was validated by collecting oxygen flux data for a dense perovskite ceramic membrane at 1000 degrees C under a wide range of concentrations and flow rates of CO and CO2 on one side and air on the other side of the membrane. The results show that an order of magnitude variation in the oxygen flux can be produced merely by changing the reducing gas flow rate. These results can help explain differences in oxygen flux data reported over a range of conditions and shed light on the rate limiting step in oxygen transport through dense oxygen conducting ceramic membranes. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 284
页数:14
相关论文
共 50 条
  • [41] Permeability of ceramic membranes to gas flow
    Innocentini, MDM
    Antunes, WL
    Baumgartner, JB
    Seville, JPK
    Coury, JR
    ADVANCED POWDER TECHNOLOGY, 1999, 299-3 : 19 - 28
  • [42] Measurements on the viscosity of oxygen gas at liquid oxygen temperatures
    Van Itterbeek, A
    Keesom, WH
    PHYSICA, 1935, 2 : 97 - 103
  • [43] Easy fabrication of dense ceramic membrane for oxygen separation
    Shao, ZP
    Xiong, GX
    Yang, WS
    CHINESE CHEMICAL LETTERS, 2000, 11 (10) : 937 - 940
  • [44] Easy Fabrication of Dense Ceramic Membrane for Oxygen Separation
    Zong Ping SHAO
    Chinese Chemical Letters, 2000, (10) : 937 - 940
  • [45] EFFECTS OF GAS FLOW RATE ON CLARK-TYPE OXYGEN GAS SENSOR
    Shan Jun LIU
    Han Xi SHEN(Department of Chemistry
    He WANG
    Jian Xing FENG(Department of Environmental Science
    Chinese Chemical Letters, 1995, (06) : 505 - 508
  • [46] Effects of gas flow rate on Clark-type oxygen gas sensor
    Liu, SJ
    Shen, HX
    Qiu, YH
    Wang, H
    Feng, JX
    CHINESE CHEMICAL LETTERS, 1995, 6 (06) : 505 - 508
  • [47] Increasing oxygen flux through a dense oxygen permeable membrane by photolithographic patterning of platinum
    Murphy, Sean M.
    Slade, David A.
    Nordheden, Karen J.
    Stagg-Williams, Susan M.
    JOURNAL OF MEMBRANE SCIENCE, 2006, 277 (1-2) : 94 - 98
  • [48] Assessment of CO2 stability and oxygen flux of oxygen permeable membranes
    Schulz, Matthias
    Kriegel, Ralf
    Kaempfer, Andrea
    JOURNAL OF MEMBRANE SCIENCE, 2011, 378 (1-2) : 10 - 17
  • [49] Oxygen permeation through perovskite membranes and the improvement of oxygen flux by surface modification
    Leo, A.
    Liu, S.
    da Costa, J. C. Diniz
    Shao, Z.
    SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2006, 7 (08) : 819 - 825
  • [50] Oxygen permeation through mixed conducting oxide membranes
    Schroeder, M
    Huang, KQ
    Goodenough, JB
    HIGH TEMPERATURE MATERIALS CHEMISTRY, PTS I AND II, PROCEEDINGS, 2000, 15 : 649 - 652