Nerve Agents Assay Using Cholinesterase Based Biosensor

被引:19
|
作者
Pohanka, Miroslav [1 ]
Dobes, Petr [3 ,4 ]
Drtinova, Lucie
Kuca, Kamil [1 ,2 ,3 ,4 ]
机构
[1] Univ Def, Fac Mil Hlth Sci, Ctr Adv Studies, Hradec Kralove, Czech Republic
[2] Univ Def, Fac Mil Hlth Sci, Dept Toxicol, Hradec Kralove, Czech Republic
[3] Acad Sci Czech Republ, Inst Organ Chem & Biochem, CR-11142 Prague, Czech Republic
[4] Univ JE Purkyne, Fac Sci, Dept Chem, Usti Nad Labem, Czech Republic
关键词
Organophophate; Biosensor; Acetylcholinesterase; Sarin; Soman; VX; Tabun; Cyclosarin; SCREEN-PRINTED ELECTRODE; AMPEROMETRIC BIOSENSOR; PORTABLE BIOSENSOR; ACETYLCHOLINESTERASE; PERFORMANCE; PESTICIDES; SENSOR; WATER; IMMOBILIZATION; NANOPARTICLES;
D O I
10.1002/elan.200804528
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical biosensor based on electric eel acetylcholinesterase (ACME) (EC 3.1.1.7) was performed for assay of nerve agents - tabun, sarin, soman, cyclosarin, and VX. The biosensor used AChE as biorecognition element. The presence of nerve agents was accompanied by it strong inhibition of AChE activity. Enzyme activity is easily measurable by electrochemical oxidation of thiocholine created front acetylthiocholine (ATChCl) by AChE-catalyzed hydrolysis. The tested nerve agents were successfully assayed. The best limits of detection were achieved for sarin (5.88 x 10(-10) M) and VX (8.51 x 10(-10) M) after one-minute assay. The biosensor was found long term stable at low as well its laboratory temperature.
引用
收藏
页码:1177 / 1182
页数:6
相关论文
共 50 条
  • [31] INFLUENCE OF CERTAIN ANTI-CHOLINESTERASE AGENTS ON TRANSMISSION OF EXCITATION IN NERVE OF FROG
    PRUDNIKOVA, IF
    [J]. BIOPHYSICS-USSR, 1961, 6 (04): : 59 - +
  • [32] A NEW SUCCINYLCHOLINE-BASED ASSAY OF PLASMA CHOLINESTERASE
    ABERNETHY, MH
    GEORGE, PM
    MELTON, VE
    [J]. CLINICAL CHEMISTRY, 1984, 30 (02) : 192 - 195
  • [33] Fully integrated ready-to-use paper-based electrochemical biosensor to detect nerve agents
    Cinti, Stefano
    Minotti, Clarissa
    Moscone, Danila
    Palleschi, Giuseppe
    Arduini, Fabiana
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 93 : 46 - 51
  • [34] A disposable biosensor for organophosphorus nerve agents based on carbon nanotubes modified thick film strip electrode
    Joshi, KA
    Tang, J
    Haddon, R
    Wang, J
    Chen, W
    Mulchandani, A
    [J]. ELECTROANALYSIS, 2005, 17 (01) : 54 - 58
  • [35] Flow injection amperometric detection of OP nerve agents based on an organophosphorus-hydrolase biosensor detector
    Wang, J
    Krause, R
    Block, K
    Musameh, M
    Mulchandani, A
    Schöning, MJ
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3): : 255 - 260
  • [36] A microneedle biosensor for minimally-invasive transdermal detection of nerve agents
    Mishra, Rupesh K.
    Mohan, A. M. Vinu
    Soto, Fernando
    Chrostowski, Robert
    Wang, Joseph
    [J]. ANALYST, 2017, 142 (06) : 918 - 924
  • [37] Direct monitoring of organophosphorus nerve agents by amperometric enzyme biosensor.
    Mulchandani, A
    Mulchandani, P
    Kanifar, H
    Chen, W
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U789 - U790
  • [38] Oxidation of organophosphorus pesticides for the sensitive detection by a cholinesterase-based biosensor
    Lee, HS
    Kim, YA
    Cho, YA
    Lee, YT
    [J]. CHEMOSPHERE, 2002, 46 (04) : 571 - 576
  • [39] POTENTIOMETRIC ASSAY OF CHOLINESTERASE
    GIBSON, K
    GUILBAULT, GG
    [J]. ANALYTICA CHIMICA ACTA, 1975, 76 (02) : 245 - 251
  • [40] MODIFIED ASSAY FOR CHOLINESTERASE
    HOOVER, DB
    KOSA, J
    COLASANTI, BK
    CRAIG, CR
    [J]. MICROCHEMICAL JOURNAL, 1976, 21 (03) : 267 - 271