Treatment Verification of the Elekta Unity MR-Linac Adapted Workflow Using in Vivo 3D EPID Dosimetry

被引:0
|
作者
Ruiz, I. Olaciregui [1 ]
Xirau, I. Torres [1 ]
van der Heide, U. [1 ]
Mans, A. [1 ]
机构
[1] Netherlands Canc Inst, Amsterdam, Netherlands
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
TU-HI-SAN4
引用
收藏
页码:E367 / E367
页数:1
相关论文
共 50 条
  • [41] EPID-based 3D in vivo dosimetry in head and neck radiotherapy
    Biltekin, F.
    Yazici, G.
    Ozyigit, G.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1354 - S1355
  • [42] EPID-based 3D dosimetry for pre-treatment FFF VMAT stereotactic body radiotherapy plan verification using dosimetry Check™
    Chendi, Agnese
    Botti, Andrea
    Orlandi, Matteo
    Sghedoni, Roberto
    Iori, Mauro
    Cagni, Elisabetta
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 227 - 236
  • [43] Implementation of An Efficient Workflow for the Analysis of Alerts Observed During Large Scale EPID-Based 3D in Vivo Dosimetry
    Mijnheer, B.
    van Mourik, A.
    Ruiz, I. Olaciregui
    Mans, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 2989 - 2989
  • [44] Sources of out-of-field dose in MRgRT: an inter-comparison of measured and Monaco treatment planning system doses for the Elekta Unity MR-linac
    Baines, John
    Powers, Marcus
    Newman, Glen
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (04) : 1049 - 1059
  • [45] Comprehensive 3D verification of SRS treatments with virtual spherical phantom EPID dosimetry
    Greer, P.
    Dempsey, C.
    Kaur, G.
    Zwan, B.
    Kandasamy, K.
    Calvo-Ortega, J. F.
    Ostwald, P.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S542 - S544
  • [46] Sources of out-of-field dose in MRgRT: an inter-comparison of measured and Monaco treatment planning system doses for the Elekta Unity MR-linac
    John Baines
    Marcus Powers
    Glen Newman
    Physical and Engineering Sciences in Medicine, 2021, 44 : 1049 - 1059
  • [47] In Vivo 3D Dose Verification for IMRT Using Electronic Portal Imaging Device (EPID)
    Chang, C.
    Anderson, N. G.
    Zhu, T. C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [48] First clinical experience with pre-treatment and in vivo IMRT verification using EPID dosimetry
    McDermott, LN
    Wendling, M
    Sonke, J
    Stroom, J
    van Asselen, B
    van Herk, M
    Mijnheer, B
    MEDICAL PHYSICS, 2005, 32 (06) : 2090 - 2090
  • [49] Measurement of 3D dose distributions from an MR Linac with gel dosimetry
    Roed, Y.
    Pinsky, L.
    Ibbott, G.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S769 - S770
  • [50] 3D Portal Dosimetry for extreme hypofraction: pre-treatment and in vivo verification
    Pereira, M.
    Stroom, J.
    Rocha, A.
    Greco, C.
    Nijsten, S.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S724 - S726