Spatial distribution of internal heat gains: A probabilistic representation and evaluation of its influence on cooling equipment sizing in large office buildings

被引:18
|
作者
Zhang, Qi [1 ]
Yan, Da [1 ]
An, Jingjing [1 ]
Hong, Tianzhen [2 ]
Tian, Wei [3 ]
Sun, Kaiyu [2 ]
机构
[1] Tsinghua Univ, Sch Architecture, Building Energy Res Ctr, Beijing, Peoples R China
[2] Lawrence Berkeley Natl Lab, Building Technol & Urban Syst Div, Berkeley, CA 94720 USA
[3] Tianjin Univ Sci & Tecnol, Coll Mech Engn, Tianjin, Peoples R China
基金
英国工程与自然科学研究理事会; 美国国家科学基金会; 中国国家自然科学基金;
关键词
Internal heat gain; Spatial diversity; Stochastic Spatial distribution; Air handling unit; Equipment sizing; Chiller plant; SENSITIVITY-ANALYSIS; PERFORMANCE SIMULATION; PRACTICAL APPLICATION; UNCERTAINTY ANALYSIS; OCCUPANT BEHAVIOR; PATTERNS; LOAD;
D O I
10.1016/j.enbuild.2017.01.044
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Internal heat gains from occupants, lighting, and plug loads are significant components of the space cooling load in an office building. Internal heat gains vary with time and space. The spatial diversity is significant, even for spaces with the same function in the same building. The stochastic nature of internal heat gains makes determining the peak cooling load to size air-conditioning systems a challenge. The traditional conservative practice of considering the largest internal heat gain among spaces and applying safety factors overestimates the space cooling load, which leads to oversized air-conditioning equipment and chiller plants. In this study, a field investigation of several large office buildings in China led to the development of a new probabilistic approach that represents the spatial diversity of the design internal heat gain of each tenant as a probability distribution function. In a large office building, a central chiller plant serves all air handling units (AHUs), with each AHU serving one or more floors of the building. Therefore, the spatial diversity should be considered differently when the peak cooling loads to size the AHUs and chillers are calculated. The proposed approach considers two different levels of internal heat gains to calculate the peak cooling loads and size the AHUs and chillers in order to avoid oversizing, improve the overall operating efficiency, and thus reduce energy use. (C)2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:407 / 416
页数:10
相关论文
共 3 条
  • [1] Uncertainty Propagation of Internal Heat Gains for Building Thermal Behaviour Assessment: Influence of Spatial Distribution
    Gauvrit, Jordan
    Caucheteux, Antoine
    Lecoeuche, Stephane
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 4706 - 4713
  • [2] Evaluation of spatial and temporal distribution of PMV with considering control and performance change of HVAC system: Thermal environment evaluation in office over cooling period with direct cooling system of internal heat gain Part 2
    Wang L.
    Kato S.
    Zhang W.
    Hwang H.
    Sato T.
    Sekine K.
    1600, Architectural Institute of Japan (82): : 237 - 247
  • [3] Comparison with conventional system focusing on space distribution and time change characteristics: Thermal environment evaluation in office over cooiling period with direct cooling system of internal heat gain Part 1
    Yoshidomi T.
    Kato S.
    Zhang W.
    Sekine K.
    Sato T.
    Hwang H.
    J. Environ. Eng., 723 (429-437): : 429 - 437