Application of the dual energy technique by using a photon counting CdTe detector

被引:0
|
作者
Zou, Wenjuan [1 ]
Nakashima, Takuya [1 ]
Onishi, Yoshiaki [1 ]
Morii, Hisashi [1 ]
Neo, Yoichiro [1 ]
Mimura, Hidenori [1 ]
Aoki, Toru [1 ]
机构
[1] Shizuoka Univ, Elect Res Inst, Hamamatsu, Shizuoka 4328011, Japan
关键词
CdTe line detector; computed tomography; linear attenuation coefficient; atomic number; electron density;
D O I
10.1117/12.794634
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have proposed a new system for X-ray computed tomography (CT) scanning. By employing the dual-energy measurement, the obtained data can be used to deduce distribution images of the atomic number and electron density which are useful for identifying the scanned material. In this work, two different methods were given for the derivative process. We found method A was suitable for measuring low-Z materials while method B worked well for high-Z materials. Therefore, the two derivative methods may work complementally for material identification.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Measurements of a Dual-Energy Fast Photon Counting CdTe Detector with Integrated Charge Sharing Correction
    Ullberg, Christer
    Urech, Mattias
    Weber, Niclas
    Engman, Anders
    Redz, Anna
    Henckel, Fredrik
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [2] Detector response function of an energy-resolved CdTe single photon counting detector
    Liu, Xin
    Lee, Hyoung Koo
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (06) : 735 - 744
  • [3] Material discrimination study of dual-energy imaging using photon counting detector
    Hao Jia
    Zhang Li
    Xing Yuxiang
    Kang Kejun
    Xiao Yongshun
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 524 - 527
  • [4] Analysis of artifact with X-ray CT using energy band by photon counting CdTe detector
    Matsumoto, G.
    Imura, Y.
    Morii, H.
    Miyake, A.
    Aoki, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 292 - 294
  • [5] Multi-contrast CT imaging using a high energy resolution CdTe detector and a CZT photon-counting detector
    Clements, N.
    Richtsmeier, D.
    Hart, A.
    Bazalova-Carter, M.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (01)
  • [6] Impact of Photon Counting Detector Spectral Response on Dual Energy Techniques
    Wang, Adam S.
    Pelc, Norbert J.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [7] Energy Spectra Measurements with a CdTe-Based Imaging Photon Counting Detector (PCD)
    Shankar, A.
    Krebs, J.
    Russ, M.
    Bednarek, D.
    Rudin, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 3202 - 3202
  • [8] Quantification of breast composition by using a dual-energy technique with a photon-counting detector: Monte Carlo simulation studies
    Seungwan Lee
    Yu-Na Choi
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2014, 64 : 305 - 312
  • [9] Quantification of breast composition by using a dual-energy technique with a photon-counting detector: Monte Carlo simulation studies
    Lee, Seungwan
    Choi, Yu-Na
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (02) : 305 - 312
  • [10] Simultaneous dual-energy x-ray and gamma ray imaging using an ultra-fast CdTe photon-counting detector
    Alhassen, Fares
    Huang, Shih-Ying
    Gould, Robert
    Barber, WIlliam
    Hartsough, Neal
    Wessel, Jan C.
    Malakhov, Nail
    Iwanczyk, Jan
    Seo, Youngho