MR Fingerprinting for Rapid Quantification of Myocardial T1, T2, and Proton Spin Density

被引:190
|
作者
Hamilton, Jesse I. [1 ]
Jiang, Yun [1 ]
Chen, Yong [2 ]
Ma, Dan [1 ]
Lo, Wei-Ching [1 ]
Griswold, Mark [1 ,2 ]
Seiberlich, Nicole [1 ,2 ]
机构
[1] Case Western Reserve Univ, Biomed Engn, 10900 Euclid Ave, Cleveland, OH 44106 USA
[2] Univ Hosp, Case Med Ctr, Radiol, Cleveland, OH USA
关键词
MR fingerprinting; quantitative imaging; relaxation time; spiral; CARDIOVASCULAR MAGNETIC-RESONANCE; LONGITUDINAL RELAXATION-TIME; LOOK-LOCKER; 3; T; BLOOD; RECOVERY; HEART; RECONSTRUCTION; INFARCTION; TISSUE;
D O I
10.1002/mrm.26216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To introduce a two-dimensional MR fingerprinting (MRF) technique for quantification of T-1, T-2, and M0 in myocardium. Methods: An electrocardiograph-triggered MRF method is introduced for mapping myocardial T-1, T-2, and M-0 during a single breath-hold in as short as four heartbeats. The pulse sequence uses variable flip angles, repetition times, inversion recovery times, and T-2 preparation dephasing times. A dictionary of possible signal evolutions is simulated for each scan that incorporates the subject's unique variations in heart rate. Aspects of the sequence design were explored in simulations, and the accuracy and precision of cardiac MRF were assessed in a phantom study. In vivo imaging was performed at 3 Tesla in 11 volunteers to generate native parametric maps. Results: T-1 and T-2 measurements from the proposed cardiac MRF sequence correlated well with standard spin echo measurements in the phantom study (R-2 > 0.99). A Bland-Altman analysis revealed good agreement for myocardial T-1 measurements between MRF and MOLLI (bias 1 ms, 95% limits of agreement -72 to 72 ms) and T-2 measurements between MRF and T-2-prepared balanced steady-state free precession (bias, 2.6 ms; 95% limits of agreement, 8.5 to 3.3 ms). Conclusion: MRF can provide quantitative single slice T-1, T-2, and M-0 maps in the heart within a single breath-hold. (C) 2016 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1446 / 1458
页数:13
相关论文
共 50 条
  • [41] 3D MR fingerprinting (MRF) for simultaneous T1 and T2 quantification of the bone metastasis: Initial validation in prostate cancer patients
    Choi, Moon Hyung
    Lee, Sheen-Woo
    Kim, Hyun Gi
    Kim, Jee Young
    Oh, Se Won
    Han, Dongyeob
    Kim, Dong-Hyun
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 144
  • [42] 3D magnetic resonance fingerprinting for rapid simultaneous T1, T2, and T1ρ volumetric mapping of human articular cartilage at 3 T
    Sharafi, Azadeh
    Zibetti, Marcelo V. W.
    Chang, Gregory
    Cloos, Martijn
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2022, 35 (12)
  • [43] Feasibility of Quantitative Magnetic Resonance Fingerprinting in Ovarian Tumors for T1 and T2 Mapping in a PET/MR Setting
    Kaggie, Joshua D.
    Deen, Surrin
    Kessler, Dimitri A.
    McLean, Mary A.
    Buonincontri, Guido
    Schulte, Rolf F.
    Addley, Helen
    Sala, Evis
    Brenton, James
    Graves, Martin J.
    Gallagher, Ferdia A.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (04) : 509 - 515
  • [44] Simultaneous bilateral T1, T2, and T1ρ relaxation mapping of the hip joint with magnetic resonance fingerprinting
    Sharafi, Azadeh
    Zibetti, Marcelo V. W.
    Chang, Gregory
    Cloos, Martijn A.
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2022, 35 (05)
  • [45] Myocardial T1 and T2 mappings with automatic motion correction at 3 Tesla MR: comparison of T1 and T2 measurements by breathhold, free-breathing and cardiac cycle
    Yon Mi Sung
    Hwanseok Yong
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [46] Magnetic resonance fingerprinting with quadratic RF phase for measurement of T2* simultaneously with δf,T1, and T2
    Wang, Charlie Yi
    Coppo, Simone
    Mehta, Bhairav Bipin
    Seiberlich, Nicole
    Yu, Xin
    Griswold, Mark Alan
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1849 - 1862
  • [47] Minimum acquisition methods for simultaneously imaging T1, T2, and proton density with B1 correction and no spin-echoes
    Wang, Guan
    El-Sharkawy, AbdEl-Monem M.
    Bottomley, Paul A.
    JOURNAL OF MAGNETIC RESONANCE, 2014, 242 : 243 - 255
  • [48] Quantification Correction for Rapid Myocardial T1ρ Mapping in Mice Using the T1ρ* Relaxation Pathway
    Gram, Maximilian
    Gensler, Daniel
    Winter, Patrick
    Arias-Loza, Anahi-Paula
    Jakob, Peter M.
    Nordbeck, Peter
    CIRCULATION, 2021, 144
  • [49] SIMULTANEOUS ACQUISITION OF PROTON DENSITY, T1, AND T2 IMAGES WITH TRIPLE CONTRAST RARE SEQUENCE
    OSHIO, K
    JOLESZ, FA
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (02) : 333 - 338
  • [50] Feasibility of 3D MRI fingerprinting for rapid knee cartilage T1, T2, and T1ρ mapping at 0.55T: Comparison with 3T
    De Moura, Hector L.
    Monga, Anmol
    Zhang, Xiaoxia
    Zibetti, Marcelo V. W.
    Keerthivasan, Mahesh B.
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2024, 37 (12)