Validation of the OMI-TOMS and OMI-DOAS total ozone column data using ground-based observations over China

被引:0
|
作者
Ma, Mingliang [1 ,2 ,3 ]
Shi, Runhe [1 ,2 ,3 ]
Gao, Wei [1 ,2 ,3 ,4 ,5 ]
机构
[1] E China Normal Univ, Key Lab Geog Informat Sci, Minist Educ, Shanghai 200241, Peoples R China
[2] E China Normal Univ, Joint Lab Environm Remote Sensing & Data Assimila, Shanghai 200241, Peoples R China
[3] Chinese Acad Sci, Inst Remote Sensing & Digital Earth, Shanghai 200241, Peoples R China
[4] Colorado State Univ, Nat Resource Ecol Lab, Ft Collins, CO 80521 USA
[5] Colorado State Univ, Dept Ecosyst Sci & Sustainabil, Ft Collins, CO 80521 USA
关键词
Validation; OMI-TOMS; OMI-DOAS; Total Ozone Column; China;
D O I
10.1117/12.2186782
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
This study evaluates the accuracy of total ozone column derived from Ozone Monitoring Instruments (OMI) with two algorithms: OMI Total Ozone Mapping Spectrometer (OMI-TOMS) and OMI Differential Optical Absorption Spectroscopy (OMI-DOAS), compared to ground-based Brewer and Dobson spectrophotometers located at eight China stations from July 2009 to December 2013, including Xianghe, Kunming, Mt. Waliguan, Lhasa, Taipei, Chengkung, Cape D'Aguilar and Longfengshan. Results showed that the agreement between OMI ozone data and ground-based measurements is excellent. Total ozone columns from both OMI-TOMS and OMI-DOAS data are on average about 1.5% lower than ground-based data. For both OMI ozone data products the SZA dependence of the mean relative differences (RD) between satellite data and the ground-based data is relative obvious when the SZA is larger than 50 degrees. Similar to the SZA, the satellite view zenith angle (VZA) dependence of the mean relative differences (RD) between satellite and ground is relatively markedly when the VZA is smaller than 10 degrees in eight stations. Finally, the dependence of the mean relative differences (RD) (-4.28% to 0.818%) between OMI-DOAS data and ground-based data for the total ozone column is remarkable. While for OMI-TOMS data the dependence is not obvious (the RD value varies from -3.30% to -0.676%).
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Ambient Formaldehyde over the United States from Ground-Based (AQS) and Satellite (OMI) Observations
    Wang, Peidong
    Holloway, Tracey
    Bindl, Matilyn
    Harkey, Monica
    De Smedt, Isabelle
    REMOTE SENSING, 2022, 14 (09)
  • [22] Tropospheric ozone column retrieval from OMI data by means of neural networks: a validation exercise with ozone soundings over Europe
    Antonio Di Noia
    Pasquale Sellitto
    Fabio Del Frate
    Marco Cervino
    Marco Iarlori
    Vincenzo Rizi
    EURASIP Journal on Advances in Signal Processing, 2013
  • [23] Quasi-biennial oscillation of the total ozone and ozone concentrations at separate altitude levels over Arctic and Tomsk according to TOMS, OMI, and MLS observations
    Bazhenov, Oleg
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2015, 36 (12) : 3033 - 3040
  • [24] Tropospheric ozone column retrieval from OMI data by means of neural networks: a validation exercise with ozone soundings over Europe
    Di Noia, Antonio
    Sellitto, Pasquale
    Del Frate, Fabio
    Cervino, Marco
    Iarlori, Marco
    Rizi, Vincenzo
    EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2013,
  • [25] Spatiotemporal Variations and Influent Factors of Tropospheric Ozone Concentration over China Based on OMI Data
    Zhu, Lei
    Liu, Minxia
    Song, Jiaying
    ATMOSPHERE, 2022, 13 (02)
  • [26] Evaluation of MACC Reanalysis Ozone Data over China Using Ground-based and AIRS Satellite Observations
    Wang R.-F.
    Ma X.-D.
    Zhao T.-L.
    Wang H.-L.
    Ding H.
    Zheng X.-B.
    Huanjing Kexue/Environmental Science, 2019, 40 (10): : 4412 - 4422
  • [27] Nitrogen dioxide DOAS measurements from ground and space: comparison of zenith scattered sunlight ground-based measurements and OMI data in Central Mexico
    Rivera, C.
    Stremme, W.
    Grutter, M.
    ATMOSFERA, 2013, 26 (03): : 401 - 414
  • [28] Validation of total ozone column derived from OMPS using ground-based spectroradiometer measurements
    Chen, Zuoqi
    Yu, Bailang
    Huang, Yan
    Hu, Yingjie
    Lin, Hao
    Wu, Jianping
    REMOTE SENSING LETTERS, 2013, 4 (10) : 937 - 945
  • [29] Intercomparison of total column ozone data from the Pandora spectrophotometer with Dobson, Brewer, and OMI measurements over Seoul, Korea
    Kim, Jiyoung
    Kim, Jhoon
    Cho, Hi-Ku
    Herman, Jay
    Park, Sang Seo
    Lim, Hyun Kwang
    Kim, Jae-Hwan
    Miyagawa, Koji
    Lee, Yun Gon
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2017, 10 (10) : 3661 - 3676
  • [30] Combined characterisation of GOME and TOMS total ozone measurements from space using ground-based observations from the NDSC
    Lambert, JC
    Van Roozendael, M
    Simon, PC
    Pommereau, JP
    Goutail, F
    Gleason, JF
    Andersen, SB
    Arlander, DW
    Van, NAB
    Claude, H
    de la Noë, J
    De Mazière, M
    Dorokhov, V
    Eriksen, P
    Green, A
    Tornkvist, KK
    Hoiskar, BAK
    Kyrö, E
    Leveau, J
    Merienne, MF
    Milinevsky, G
    Roscoe, HK
    Sarkissian, A
    Shanklin, JD
    Stähelin, J
    Tellefsen, CW
    Vaughan, G
    LIFE SCIENCES: PLANETARY PROTECTION; OZONE AND UVB RADIATION EFFECTS, 2001, 26 (12): : 1931 - 1940