Clinical introduction of Monte Carlo treatment planning for lung stereotactic body radiotherapy

被引:29
|
作者
Miura, Hideharu [1 ]
Masai, Norihisa [1 ]
Oh, Ryoong-Jin [1 ]
Shiomi, Hiroya [1 ]
Yamada, Kouichi [1 ]
Sasaki, Junichi [1 ]
Inoue, Toshihiko [1 ]
机构
[1] Miyakojima IGRT Clin, Osaka 5340021, Japan
来源
关键词
Monte Carlo dose calculation; lung density; GTV size; dose prescription; stereotactic body radiation therapy; RADIATION-THERAPY; DOSIMETRIC EVALUATION; DOSE CALCULATION; CANCER; VERIFICATION; ALGORITHMS; FRACTIONS; OUTCOMES; VOLUME; GY;
D O I
10.1120/jacmp.v15i1.4202
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate the impact of Monte Carlo (MC) calculations and optimized dose definitions in stereotactic body radiotherapy (SBRT) for lung cancer patients. We used a retrospective patient review and basic virtual phantom to determine dose prescriptions. Fifty-three patients underwent SBRT. A basic virtual phantom had a gross tumor volume (GTV) of 10.0 mm with equivalent water density of 1.0 g/cm(3), which was surrounded by equivalent lung surrounding the GTV of 0.25 g/cm(3). D95 of the planning target volume (PTV) and D99 of the GTV were evaluated with different GTV sizes (5.0 to 30.0 mm) and different lung densities (0.05 to 0.45 g/cm(3)). Prescribed dose was defined as 95% of the PTV should receive 100% of the dose (48 Gy/4 fractions) using pencil beam (PB) calculation and recalculated using MC calculation. In the patient study, average doses to the D95 of the PTV and D99 of the GTV using the MC calculation plan were 19.9% and 10.2% lower than those by the PB calculation plan, respectively. In the phantom study, decreased doses to the D95 of the PTV and D99 of the GTV using the MC calculation plan were accompanied with changes GTV size from 30.0 to 5.0 mm, which was decreased from 8.4% to 19.6% for the PTV and from 17.4% to 27.5% for the GTV. Similar results were seen with changes in lung density from 0.45 to 0.05 g/cm(3), with doses to the D95 of the PTV and D99 of the GTV were decreased from 12.8% to 59.0% and from 7.6% to 44.8%, respectively. The decrease in dose to the PTV with MC calculation was strongly dependent on lung density. We suggest that dose definition to the GTV for lung cancer SBRT be optimized using MC calculation. Our current clinical protocol for lung SBRT is based on a prescribed dose of 44 Gy in 4 fractions to the GTV using MC calculation.
引用
收藏
页码:38 / 46
页数:9
相关论文
共 50 条
  • [21] Markov chain Monte Carlo methods in radiotherapy treatment planning
    Hugtenburg, RP
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 583 - 588
  • [22] A Monte Carlo dose calculation tool for radiotherapy treatment planning
    Ma, CM
    Li, JS
    Pawlicki, T
    Jiang, SB
    Deng, J
    Lee, MC
    Koumrian, T
    Luxton, M
    Brain, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10): : 1671 - 1689
  • [23] Multiple Gating for Lung Stereotactic Body Radiotherapy Treatment
    Li, T.
    Yang, Y.
    Li, X.
    Li, F.
    Heron, D.
    Huq, M.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [24] A Monte Carlo investigation of lung brachytherapy treatment planning
    Sutherland, J. G. H.
    Furutani, K. M.
    Thomson, R. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (14): : 4763 - 4780
  • [25] Dosimetric Verification Using Monte Carlo Calculations for Tissue Heterogeneity-corrected Conformal Treatment Plans for Lung Cancer Stereotactic Body Radiotherapy
    Li, J.
    Galvin, J.
    Harrison, A.
    Timmerman, R.
    Yu, Y.
    Xiao, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S854 - S854
  • [26] Monte Carlo Evaluation of Tissue Inhomogeneity Corrections in the Treatment of Liver Cancer Patients Using Stereotactic Body Radiotherapy
    Pokhrel, D.
    Sood, S.
    Badkul, R.
    McClinton, C.
    Jiang, H.
    Saleh, H.
    Lominska, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3603 - 3603
  • [27] Is Monte Carlo-Based Dose Calculation Algorithm Required for All Lung Tumors Treated with Stereotactic Body Radiotherapy?
    Saleh, H.
    TeNapel, M.
    Soultan, D.
    Smith, M.
    Edds, J.
    Wang, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E783 - E784
  • [28] Reducing dosimetric treatment uncertainties in hypofractionated stereotactic body radiotherapy (SBRT) planning for lung cancers
    Chao, K.
    Grills, I. S.
    Yan, D.
    Kestin, L. L.
    Martinez, A. A.
    Hugo, G. D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S662 - S663
  • [29] A Treatment Planning Study of Stereotactic Body Radiotherapy for Atrial Fibrillation
    Xia, Ping
    Kotecha, Rupesh
    Sharma, Naveen
    Andrews, Martin
    Stephans, Kevin L.
    Oberti, Carlos
    Lin, Sara
    Wazni, Oussama
    Tchou, Patrick
    Saliba, Walid I.
    Suh, John
    CUREUS, 2016, 8 (07):
  • [30] Four-dimensional treatment planning for stereotactic body radiotherapy
    Guckenberger, Matthias
    Wilbert, Juergen
    Krieger, Thomas
    Richter, Anne
    Baier, Kurt
    Meyer, Juergen
    Flentje, Michael
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 276 - 285