摘要
BACKGROUND: The purpose of the study was to analyze qualitatively and quantitatively anatomic relationships of anterior chamber Baikoff phakic intraocular lenses (IOL) to the cornea, angle, iris, and lens in myopic eyes. METHODS: Thirteen phakic myopic eyes (-9.00 to -15.00 diopters) corrected by minus power, angle-supported, anterior chamber intraocular lenses of the ZB5M style (Chiron-Domilens), with a mean follow-up of 25 months (range 18 to 36 months), were examined clinically and by ultrasound biomicroscopy. RESULTS: The mean distance (+/-SD) between the central cornea and the IOL was 2.05 +/- 0.18 mm (range 1.8 to 2.47 mm); mean distance between the corneal periphery and the IOL was 1.56 +/- 0.17 mm (range 1.33 to 1.95 mm); and the mean distance between the POL and the lens was 0.58 +/- 0.12 mm (range 0.48 to 0.81 mm). IOL footplates seemed to be correctly positioned in the angle in all eyes. We observed no goniosynechiae. In six eyes, we found localized posterior indentation of the iris caused by the haptics. Four of these six eyes exhibited oval pupils associated with an oversized IOL. CONCLUSIONS: High frequency ultrasound biomicroscopy can define anatomic relationships of anterior chamber phakic IOLs, and help analyze the mechanisms of corneal and iris complications.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 50 条
  • [41] FLUOROPHOTOMETRY IN MYOPIC PHAKIC EYES WITH ANTERIOR-CHAMBER INTRAOCULAR LENSES TO CORRECT SEVERE MYOPIA
    PEREZSANTONJA, JJ
    HERNANDEZ, JL
    DELCASTILLO, JMB
    RODRIGUEZBERMEJO, C
    ZATO, MA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (03) : 316 - 321
  • [42] Alterations in the anterior chamber angle after implantation of iris-fixated phakic intraocular lenses
    Yamaguchi, Takefumi
    Negishi, Kazuno
    Yuki, Kenya
    Saiki, Megumi
    Nishimura, Ryo
    Kawaguchi, Nanae
    Tsubota, Kazuo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (08): : 1300 - 1305
  • [43] Anterior segment OCT and phakic intraocular lenses:: A perspective
    Baikoff, Georges
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11): : 1827 - 1835
  • [44] ANTERIOR-CHAMBER INTRAOCULAR LENSES
    HESSBURG, PC
    ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (02) : 165 - 165
  • [45] Secondary anterior chamber intraocular lenses
    Dixon, WS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (01): : 7 - 7
  • [46] Long-term ultrasound biomicroscopy observation of position changes of a copolymer posterior chamber phakic intraocular lens
    Cao, Xinfang
    Tong, Jianping
    Wang, Yang
    Zhou, Tian'an
    Ye, Bei
    Li, Xiuyi
    Shen, Ye
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (09): : 1454 - 1461
  • [48] Phakic posterior chamber intraocular lenses for the correction of high ametropia
    Belmont, SC
    Kim, DY
    Hatsis, AP
    Rozakis, GW
    Reinstein, DZ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 2508 - 2508
  • [49] Ultrasound Biomicroscopy of Iris-claw Phakic Intraocular Lens Implantation
    Ayong Yu
    眼科学报, 2006, (01) : 35 - 39
  • [50] Posterior chamber phakic intraocular lenses after penetrating keratoplasty
    Alfonso, Jose F.
    Lisa, Carlos
    Abdelhamid, Abdelhamid
    Montes-Mico, Robert
    Poo-Lopez, Arancha
    Ferrer-Blasco, Teresa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1166 - 1173