Diagnostic accuracy of multidetector computed tomography coronary angiography in 325 consecutive patients referred for transcatheter aortic valve replacement

被引:61
|
作者
Andreini, Daniele [1 ,2 ]
Pontone, Gianluca [1 ]
Mushtaq, Saima [1 ]
Bartorelli, Antonio L. [1 ,2 ]
Ballerini, Giovanni [1 ]
Bertella, Erika [1 ]
Segurini, Chiara [1 ]
Conte, Edoardo [1 ]
Annoni, Andrea [1 ]
Baggiano, Andrea [1 ]
Formenti, Alberto [1 ]
Fusini, Laura [1 ]
Tamborini, Gloria [1 ]
Alamanni, Francesco [1 ,2 ]
Fiorentini, Cesare [1 ,2 ]
Pepi, Mauro [1 ]
机构
[1] IRCCS Milan, Ctr Cardiol Monzino, Milan, Italy
[2] Univ Milan, Dept Clin Sci & Community Hlth, Cardiovasc Sect, Milan, Italy
关键词
ARTERY-DISEASE; CT; FEASIBILITY;
D O I
10.1016/j.ahj.2014.04.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Multidetector computed tomography (MDCT) provides detailed assessment of valve annulus and iliofemoral vessels in transcatheter aortic valve replacement (TAVR) patients. However, data on diagnostic performance of MDCT coronary angiography (MDCT-CA) are scarce. The aim of the study is to assess diagnostic performance of MDCT for coronary artery evaluation before TAVR. Methods A total of 325 consecutive patients (234 without previous myocardial revascularization, 49 with previous coronary stenting, and 42 with previous coronary artery bypass graft [CABG]) underwent invasive coronary angiography and MDCT before TAVR. MDCT-CA was performed using the same data set dedicated to standard MDCT aortic annulus evaluation. Multidetector computed tomography-CA evaluability and diagnostic accuracy in comparison with invasive coronary angiography as criterion standard were assessed. Results The MDCT-CA evaluability of native coronaries was 95.6%. The leading cause of unevaluability was beam-hardening artifact due to coronary calcifications. In a segment-based analysis, MDCT-CA showed sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for detecting >= 50% stenosis of 91%, 99.2%, 83.4%, 99.6% and 98.8%, respectively. The MDCT-CA evaluability of coronary stents was 82.1%. In a segment-based analysis, MDCT-CA showed sensitivity, specificity, PPV, NPV, and accuracy for detecting >= 50% in-stent restenosis of 94.1%, 86.7%, 66.7%, 98.1%, and 88.3%, respectively. All CABGs were correctly assessed by MDCT-CA. In a patient-based analysis, MDCT-CA showed sensitivity, specificity, PPV, NPV, and accuracy of 89.7%, 90.8%, 80.6%, 95.4%, and 90.5%, respectively. Conclusions Multidetector computed tomography-CA allows to correctly rule out the presence of significant native coronary artery stenosis, significant in-stent restenosis, and CABG disease in patients referred for TAVR.
引用
收藏
页码:332 / 339
页数:8
相关论文
共 50 条
  • [21] Diagnostic accuracy of 64-slice multidetector computed tomography for the evaluation of aortic root in patients selected for transcatheter aortic valve implantation
    Pontone, G.
    Andreini, D.
    Bertella, E.
    Mushtaq, S.
    Annoni, A. D.
    Tamborini, G.
    Fusari, M.
    Ballerini, G.
    Bartorelli, A. L.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2010, 31 : 292 - 292
  • [22] Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
    Leipsic, Jonathon
    Gurvitch, Ronen
    LaBounty, Troy M.
    Min, James K.
    Wood, David
    Johnson, Mark
    Ajlan, Amr M.
    Wijesinghe, Namal
    Webb, John G.
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) : 416 - 429
  • [23] Detection of significant coronary artery disease using computed tomography coronary angiography in patients with aortic stenosis referred for surgical aortic valve replacement
    Larsen, L. H.
    Kofoed, K. F.
    Dalsgaard, M.
    Kristensen, T.
    Elming, H.
    Steinbruchel, D. A.
    Koeber, L.
    Kelbaek, H.
    Hassager, C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 86 - 86
  • [24] Aortic valve calcification in 499 consecutive patients referred for computed tomography
    Galas, Anna
    Hryniewiecki, Tomasz
    Michalowska, Ilona
    Kepka, Cezary
    Abramczuk, Elzbieta
    Orlowska-Baranowska, Ewa
    Ruzyllo, Witold
    ARCHIVES OF MEDICAL SCIENCE, 2015, 11 (05) : 952 - 957
  • [25] Diagnostic accuracy of multidetector computed tomography coronary angiography in with angiographically proven coronary artery disease patients
    Kuettner, A
    Kopp, AF
    Schroeder, S
    Rieger, T
    Brunn, J
    Meisner, C
    Heuschmid, M
    Trabold, T
    Burgstahler, C
    Martensen, J
    Schoebel, W
    Selbmann, HK
    Claussen, CD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 831 - 839
  • [26] Diagnostic accuracy of 64-slice computed tomography for diagnosis of aortic regurgitation in patients referred to coronary CT angiography
    Feuchtner, Gudrun
    Friedrich, Guy
    Bonatti, Johannes
    Mueller, Silvana
    Schachner, Thomas
    Jodocy, Daniel
    Pachinger, Otmar
    Laufer, Guenther
    zur Nedden, Dieter
    Dichtl, Wolfgang
    CIRCULATION, 2007, 116 (16) : 410 - 410
  • [27] Noncoronary Gated Transcatheter Aortic Valve Replacement Computed Tomography Scans Can Safely Replace Invasive Coronary Angiography Pre-Transcatheter Aortic Valve Replacement
    Khan, Sarosh
    Gedela, Swamy
    Frost, Olivia M. T.
    Galinato, Michael
    Crawford, Iveta
    Smith, Sheila
    Fawaz, Samer
    Simpson, Rupert
    Singh, Arvind
    Karamasis, Grigoris, V
    Keeble, Thomas R.
    Davies, John R.
    Aggarwal, Rajesh
    Jagathesan, Rohan
    Cook, Christopher M.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2023, 7 (01):
  • [28] Comparison of Accuracy of Aortic Root Annulus Assessment With Cardiac Magnetic Resonance Versus Echocardiography and Multidetector Computed Tomography in Patients Referred for Transcatheter Aortic Valve Implantation
    Pontone, Gianluca
    Andreini, Daniele
    Bartorelli, Antonio L.
    Bertella, Erika
    Mushtaq, Saima
    Gripari, Paola
    Loguercio, Monica
    Cortinovis, Sarah
    Baggiano, Andrea
    Conte, Edoardo
    Beltrama, Virginia
    Annoni, Andrea
    Formenti, Alberto
    Tamborini, Gloria
    Muratori, Manuela
    Guaricci, Andrea
    Alamanni, Francesco
    Ballerini, Giovanni
    Pepi, Mauro
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (11): : 1790 - 1799
  • [29] Multidetector Computed Tomography to Facilitate Transcatheter Aortic Valve Implantation
    Leipsic J.
    Wood D.A.
    Gurvitch R.
    Hague C.J.
    Current Cardiovascular Imaging Reports, 2011, 4 (6) : 457 - 467
  • [30] The influence of coronary vessel dominance on prognosis in patients referred for multidetector computed tomography coronary angiography
    Veltman, C. E.
    De Graaf, F. R.
    Boersma, E.
    Werkhoven, J. M.
    Jukema, J. W.
    Kroft, L. J. M.
    De Roos, A.
    Bax, J. J.
    Schuijf, J. D.
    EUROPEAN HEART JOURNAL, 2011, 32 : 530 - 530