Functional assessment of intermediate coronary artery stenosis with 4-Fr catheters

被引:0
|
作者
Nogi, Kazutaka [1 ,2 ]
Soeda, Tsunenari [1 ]
Hara, Masahiko [3 ]
Iwama, Hajime [2 ]
Toyokawa, Nozomi [2 ]
Sakai, Satoshi [2 ]
Yano, Hiroki [1 ,2 ]
Iwai, Atsushi [2 ]
Hashimoto, Yukihiro [1 ,2 ]
Fujimoto, Hajime [2 ]
Suzuki, Megumi [2 ]
Nakai, Takehito [2 ]
Doi, Naofumi [2 ]
Saito, Yoshihiko [1 ]
机构
[1] Nara Med Univ, Dept Cardiovasc Med, 840 Shijo Cho, Kashihara, Nara 6348522, Japan
[2] Nara Prefecture Seiwa Med Ctr, Dept Cardiovasc Med, Sango, Japan
[3] Shimane Univ, Ctr Community Based Healthcare Res & Educ, Izumo, Shimane, Japan
关键词
Coronary artery disease; Functional coronary assessment; Pd; pa; Instantaneous wave-free ratio; Fractional flow reserve; FRACTIONAL FLOW RESERVE; 4; FRENCH; ACCURACY;
D O I
10.1007/s00380-020-01746-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The 4-Fr catheter system is not recommended for invasive functional assessment of coronary artery stenosis, because it tends to distort the aortic waveform. This study aimed to identify the incidence of aortic waveform distortion and a feasible method for correct diagnosis of coronary artery stenosis with a 4-Fr catheter. We retrospectively investigated 178 lesions with intermediate coronary artery stenosis. Non-hyperemic distal coronary artery pressure (Pd) and aortic pressure (Pa) were measured with a 4-Fr diagnostic or 6-Fr guiding catheter before and after saline flush. The mean Pd/mean Pa (Pd/Pa) and instantaneous wave-free ratio (iFR) were calculated before and after flushing. We compared the effect of flushing on the changes in Pd/Pa and iFR between the 4-Fr diagnostic and 6-Fr guiding catheters. Using the 4-Fr diagnostic catheter, there was a significant decrease in incidence of aortic waveform distortion from 42.0% (47 lesions) before flushing to 1.8% (2 lesions) after flushing (p < 0.001); the incidence was only 3.0% before saline flush and decreased to 0% after saline flush when using the 6-Fr guiding catheter. The presence of aortic waveform distortion influenced the iFR when the 4-Fr system was used. Functional measurements with the 4-Fr diagnostic catheter require adequate saline flush to remove the influence of aortic waveform distortion.
引用
收藏
页码:638 / 645
页数:8
相关论文
共 50 条
  • [31] Implications Of Human Coronary Autoregulation On Functional Assessment Of Coronary Artery Stenosis Significance Under Baseline Conditions
    de Waard, Guus A.
    Westerhof, Nicolaas
    Marques, Koen
    Danad, Ibrahim
    Teunissen, Paul F.
    Hollander, Maurits
    Knaapen, Paul
    van Royen, Niels
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B93 - B93
  • [32] THE ASSESSMENT OF SIGNIFICANCE OF INTERMEDIATE CORONARY STENOSIS WITH INTRAVASCULAR ULTRASOUND
    Fang Zhe
    Zhou Yujie
    Shi Dongmei
    Zhao Yingxin
    Liu Yuyang
    Li Yanfang
    HEART, 2010, 96 : A165 - A166
  • [33] Coronary CT Value in Quantitative Assessment of Intermediate Stenosis
    Zajanckauskiene, Laura
    Radionovaite, Laura
    Jankauskas, Antanas
    Banisauskaite, Audra
    Sakalyte, Gintare
    MEDICINA-LITHUANIA, 2022, 58 (07):
  • [34] Coronary artery remodelling and the assessment of stenosis by pathologists
    Davies, MJ
    HISTOPATHOLOGY, 1998, 33 (06) : 497 - 500
  • [35] The pattern of myocardial perfusion in patients with intermediate coronary artery stenosis
    Zavadovsky, K. W.
    Gulya, M. O.
    Lishmanov, Y. B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S599 - S599
  • [36] Fractional Flow Reserve for Intermediate Coronary Artery Stenosis in Nepal
    Bhattarai, Mahesh
    Maskey, Arun
    Sah, Ram Kishore
    Nepal, Himamshu
    Pandey, Rabindra
    Tamrakar, Rikesh
    Agrawal, Amit
    Malla, Rabi
    Rajbhandari, Rajib
    Adhikari, Chandra Mani
    Bhatta, Yadav Kumar Dev
    NEPALESE HEART JOURNAL, 2015, 12 (02) : 69 - 72
  • [37] Coronary artery stenosis with intermediate angiographic severity, is there a need to treat?
    Doesch, C.
    Seeger, A.
    Doering, J.
    Hoevelborn, T.
    Miller, S.
    Gawaz, M.
    May, A. E.
    EUROPEAN HEART JOURNAL, 2007, 28 : 375 - 375
  • [38] Assessment of the functional significance of coronary artery stenosis by dobutamine-atropine stress echocardiography
    Ho, YL
    Wu, CC
    Lin, LC
    Liu, YB
    Chen, WJ
    Chen, MF
    Liau, CS
    Lee, YT
    CARDIOLOGY, 1997, 88 (04) : 386 - 392
  • [39] USEFULNESS OF BLOOD SPECKLE INTENSITY ON INTRAVASCULAR ULTRASOUND FOR FUNCTIONAL ASSESSMENT OF CORONARY ARTERY STENOSIS
    Saito, Yuichi
    Kitahara, Hideki
    Nakayama, Takashi
    Fujimoto, Yoshihide
    Kobayashi, Yoshio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 357 - 357
  • [40] Challenges in Diagnosis and Functional Assessment of Coronary Artery Disease in Patients With Severe Aortic Stenosis
    Aleksandric, Srdjan
    Banovic, Marko
    Beleslin, Branko
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9