Functional assessment of intermediate coronary artery stenosis with 4-Fr catheters

被引:0
|
作者
Nogi, Kazutaka [1 ,2 ]
Soeda, Tsunenari [1 ]
Hara, Masahiko [3 ]
Iwama, Hajime [2 ]
Toyokawa, Nozomi [2 ]
Sakai, Satoshi [2 ]
Yano, Hiroki [1 ,2 ]
Iwai, Atsushi [2 ]
Hashimoto, Yukihiro [1 ,2 ]
Fujimoto, Hajime [2 ]
Suzuki, Megumi [2 ]
Nakai, Takehito [2 ]
Doi, Naofumi [2 ]
Saito, Yoshihiko [1 ]
机构
[1] Nara Med Univ, Dept Cardiovasc Med, 840 Shijo Cho, Kashihara, Nara 6348522, Japan
[2] Nara Prefecture Seiwa Med Ctr, Dept Cardiovasc Med, Sango, Japan
[3] Shimane Univ, Ctr Community Based Healthcare Res & Educ, Izumo, Shimane, Japan
关键词
Coronary artery disease; Functional coronary assessment; Pd; pa; Instantaneous wave-free ratio; Fractional flow reserve; FRACTIONAL FLOW RESERVE; 4; FRENCH; ACCURACY;
D O I
10.1007/s00380-020-01746-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The 4-Fr catheter system is not recommended for invasive functional assessment of coronary artery stenosis, because it tends to distort the aortic waveform. This study aimed to identify the incidence of aortic waveform distortion and a feasible method for correct diagnosis of coronary artery stenosis with a 4-Fr catheter. We retrospectively investigated 178 lesions with intermediate coronary artery stenosis. Non-hyperemic distal coronary artery pressure (Pd) and aortic pressure (Pa) were measured with a 4-Fr diagnostic or 6-Fr guiding catheter before and after saline flush. The mean Pd/mean Pa (Pd/Pa) and instantaneous wave-free ratio (iFR) were calculated before and after flushing. We compared the effect of flushing on the changes in Pd/Pa and iFR between the 4-Fr diagnostic and 6-Fr guiding catheters. Using the 4-Fr diagnostic catheter, there was a significant decrease in incidence of aortic waveform distortion from 42.0% (47 lesions) before flushing to 1.8% (2 lesions) after flushing (p < 0.001); the incidence was only 3.0% before saline flush and decreased to 0% after saline flush when using the 6-Fr guiding catheter. The presence of aortic waveform distortion influenced the iFR when the 4-Fr system was used. Functional measurements with the 4-Fr diagnostic catheter require adequate saline flush to remove the influence of aortic waveform distortion.
引用
收藏
页码:638 / 645
页数:8
相关论文
共 50 条
  • [1] Functional assessment of intermediate coronary artery stenosis with 4-Fr catheters
    Kazutaka Nogi
    Tsunenari Soeda
    Masahiko Hara
    Hajime Iwama
    Nozomi Toyokawa
    Satoshi Sakai
    Hiroki Yano
    Atsushi Iwai
    Yukihiro Hashimoto
    Hajime Fujimoto
    Megumi Suzuki
    Takehito Nakai
    Naofumi Doi
    Yoshihiko Saito
    Heart and Vessels, 2021, 36 : 638 - 645
  • [2] FUNCTIONAL ASSESSMENT OF INTERMEDIATE CORONARY ARTERY STENOSIS
    Carbone, Carlo
    De Rosa, Maria Luisa
    Mitrano, Lucia
    Di Serafino, Luigi
    Piccolo, Raffaele
    Franzone, Anna
    Cirillo, Plinio
    Esposito, Giovanni
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24
  • [3] Functional assessment of intermediate coronary artery stenosis.
    Tahk, SJ
    Cho, YK
    Kim, W
    Shin, JH
    Kim, HS
    Choi, BIW
    JOURNAL OF INVESTIGATIVE MEDICINE, 1996, 44 (03) : A284 - A284
  • [4] EARLY AMBULATION WITH 4-FR CORONARY ANGIOGRAPHY
    Black, A.
    Wai, B.
    Dyson, J.
    Mok, M.
    Black, A.
    INTERNAL MEDICINE JOURNAL, 2011, 41 : 2 - 2
  • [5] INTRAVASCULAR ULTRASOUND CRITERIA FOR THE ASSESSMENT OF THE FUNCTIONAL SIGNIFICANCE OF INTERMEDIATE CORONARY ARTERY STENOSIS
    Cheng Xunmin
    Jiang Shisen
    HEART, 2010, 96 : A163 - A164
  • [6] Intravascular Ultrasound Criteria for Assessment of the Functional Significance of Intermediate Coronary Artery Stenosis
    Cheng, Xunmin
    He, Guoxiang
    Liu, Jianping
    Tong, Shifei
    CIRCULATION, 2010, 122 (02) : E260 - E260
  • [7] Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenosis
    Briguori, C
    Gimelli, G
    Nishida, T
    Anzuini, A
    Corvaja, N
    Albiero, R
    Di Mario, C
    Airoldi, F
    Colombo, A
    EUROPEAN HEART JOURNAL, 2000, 21 : 505 - 505
  • [8] INTRAVASCULAR ULTRASOUND CRITERIA FOR THE ASSESSMENT OF THE FUNCTIONAL SIGNIFICANCE OF INTERMEDIATE CORONARY ARTERY STENOSIS
    Cheng Xunming
    He Guoxiang
    Liu Jianping
    Tong Shifei
    HEART, 2010, 96 : A213 - A213
  • [9] Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenosis.
    Briguori, C
    Gimelli, MG
    Nishida, T
    Anzuini, A
    Corvaja, N
    Albiero, R
    Di Mario, C
    Colombo, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (8A): : 103I - 103I
  • [10] FUNCTIONAL ASSESSMENT OF CORONARY-ARTERY STENOSIS
    MEHMEL, HC
    MAURER, W
    ZEBE, H
    OPHERK, D
    WALTHER, H
    KUBLER, W
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1977, 102 (15) : 555 - 559