Mathematical modeling for the simultaneous absorption of CO2 and SO2 using MEA in hollow fiber membrane contactors

被引:41
|
作者
Hosseinzadeh, Abolhassan [1 ]
Hosseinzadeh, Mohammadtaghi [2 ]
Vatani, Ali [1 ]
Mohammadi, Toraj [3 ,4 ]
机构
[1] Univ Tehran, Coll Chem Engn, Tehran, Iran
[2] Univ Yasuj, Yasuj, Iran
[3] Iran Univ Sci & Technol, Tehran, Iran
[4] Sch Chem Engn Tahran, Tehran, Iran
关键词
Membrane; Hollow fibers; Gas permeation; Modeling; FLUE-GAS; SIMULTANEOUS REMOVAL; AQUEOUS MEA; NATURAL-GAS; CAPTURE; SEPARATION; H2S; POLYPROPYLENE; MIXTURE; ENERGY;
D O I
10.1016/j.cep.2016.08.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, it is attempted to model and simulate simultaneous removal of CO2 and SO2 from gas streams using polypropylene hollow fiber membrane contactor (HFMC) with Monoethanolamine (MEA) as a liquid absorbent. A comprehensive two-dimensional mathematical model was developed for the transport of pollutant gases through HFMC with chemical reaction on the liquid side. The Equations that obtained for the three sections of membrane contactor with the appropriate boundary conditions were solved using the COMSOL Multiphysics software version 4.2. The effect of MEA concentration, feed gases concentration, gas and liquid velocity on absorption has been studied. The velocity profile and concentration distribution of gas and liquid are also investigated on HFMC. The modeling predictions indicated that the removal of acid gas increased with increasing the liquid velocity in the membrane contactor. Also increasing the gas velocity will decrease the acid gas removal efficiency. And increasing solvent concentration will increase removal efficiency. Finally, to validate the developed model, a comparison was made between the simulation predictions of the model and the experimental data which resulted into significant corroboration between them. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:35 / 45
页数:11
相关论文
共 50 条
  • [21] 3D-CFD Modeling of Hollow-Fiber Membrane Contactor for CO2 Absorption Using MEA Solution
    Bozonc, Alexandru-Constantin
    Sandu, Vlad-Cristian
    Cormos, Calin-Cristian
    Cormos, Ana-Maria
    MEMBRANES, 2024, 14 (04)
  • [22] Optimization of CO2 Absorption Characteristic under the Influence of SO2 in Flue Gas by Hollow Fiber Membrane Contactor
    Qu, Ziyi
    Zhang, Li
    Yan, Yunfei
    Ju, Shunxiang
    JOURNAL OF CHEMISTRY, 2016, 2016
  • [23] Experimental Investigation on the Absorption Enhancement of CO2 by Various Nanofluids in Hollow Fiber Membrane Contactors
    Peyravi, Arman
    Keshavarz, Peyman
    Mowla, Darioush
    ENERGY & FUELS, 2015, 29 (12) : 8135 - 8142
  • [24] Intensification potential of hollow fiber membrane contactors for CO2 chemical absorption and stripping using monoethanolamine solutions
    Zaidiza, David Albarracin
    Belaissaoui, Bouchra
    Rode, Sabine
    Favre, Eric
    SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 188 : 38 - 51
  • [25] Part 7: A review of CO2 capture using hollow fiber membrane contactors
    Demontigny, D. (david.demontigny@uregina.ca), 1600, Future Science Ltd (04):
  • [26] Ammonia based CO2 capture process using hollow fiber membrane contactors
    Makhloufi, Camel
    Lasseuguette, Elsa
    Remigy, Jean Christophe
    Belaissaoui, Bouchra
    Roizard, Denis
    Favre, Eric
    JOURNAL OF MEMBRANE SCIENCE, 2014, 455 : 236 - 246
  • [27] Part 7: A review of CO2 capture using hollow fiber membrane contactors
    Cui, Zheng
    deMontigny, David
    CARBON MANAGEMENT, 2013, 4 (01) : 69 - 89
  • [28] Modeling of CO2 capture by three typical amine solutions in hollow fiber membrane contactors
    Wang, R
    Li, DF
    Liang, DT
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2004, 43 (07) : 849 - 856
  • [29] CO2 Absorption Using Hollow Fiber Membrane Contactors: Introducing pH Swing Absorption (pHSA) to Overcome Purity Limitation
    Chavan, Sayali Ramdas
    Perre, Patrick
    Pozzobon, Victor
    Lemaire, Julien
    MEMBRANES, 2021, 11 (07)
  • [30] Analytical study of membrane wetting at high operating pressure for physical absorption of CO2 using hollow fiber membrane contactors
    Tantikhajorngosol, Puttipong
    Laosiripojana, Navadol
    Jiraratananon, Ratana
    Assabumrungrat, Suttichai
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 126 : 265 - 277