An ultrasensitive near-infrared ratiometric fluorescent probe for imaging mitochondrial polarity in live cells and in vivo

被引:137
|
作者
Xiao, Haibin [1 ]
Li, Ping [1 ]
Zhang, Wei [1 ]
Tang, Bo [1 ]
机构
[1] Shandong Normal Univ, Collaborat Innovat Ctr Functionalized Probes Chem, Shandong Prov Key Lab Clean Prod Fine Chem,Minist, Coll Chem Chem Engn & Mat Sci,Key Lab Mol & Nano, Jinan 250014, Peoples R China
基金
中国国家自然科学基金;
关键词
ELECTRON-TRANSFER; NILE RED; DESIGN; TUMOR;
D O I
10.1039/c5sc04099j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Mitochondrial polarity is a crucial characteristic of these indispensable organelles, and tremendously impacts cellular events. Herein, we describe a new mitochondria-targeting fluorescent probe MCY-BF2 that is singularly sensitive and specifically responsive to mitochondrial polarity. The pull-push system in the conjugated structure of MCY-BF2 is responsible for the polarity-ultrasensitivity due to the excited state intramolecular charge transfer (ICT). By combining with cardiolipin, MCY-BF2 preferentially accumulates in mitochondria. Because the fluorescence emission wavelengths exhibit an obvious red-shift with increasing media polarity, the fluorescence intensity ratio at two different wavelengths versus the solvent dielectric constant can quantify the mitochondrial polarity. Experimental results demonstrate that the fluorescent intensity of MCY-BF2 in a non-polar solvent, dioxane, is 120 times higher than that in a polar solvent, dimethyl sulfoxide. As the first near-infrared (NIR) and most sensitive fluorescent imaging probe for polarity, MCY-BF2 can locate exclusively in mitochondria in various cells and discriminate polarity differences between normal and cancer cells. Also, the intrinsic polarity variance at different developmental stages in Caenorhabditis elegans (C. elegans) was reported here for the first time. Interestingly, the embryonic development stage has a more non-polar environment with a dielectric constant of 7.20, and in contrast the polarity at the young adult stage changes to 10.07. In addition, in vivo imaging results suggest that the tumor tissues of mice have an obviously lower polarity than that in normal tissues. Altogether, the merits of the NIR property, high sensitivity and moderate Stokes shift all greatly promote the accuracy of imaging. This probe will be a promising tool for studying biological processes and the pathological mechanism of polarity-related diseases.
引用
收藏
页码:1588 / 1593
页数:6
相关论文
共 50 条
  • [21] Development of a near-infrared fluorescent probe for imaging of endogenous Cu+ in live cells
    Cao, Xiaowei
    Lin, Weiying
    Wan, Wei
    CHEMICAL COMMUNICATIONS, 2012, 48 (50) : 6247 - 6249
  • [22] Near-infrared squaraine fluorescent probe for imaging adenosine 5′-triphosphate in live cells
    Wang, Guimei
    Jiang, Xiaoxue
    Fu, Nanyan
    DYES AND PIGMENTS, 2019, 171
  • [23] A near-infrared fluorescent probe reveals decreased mitochondrial polarity during mitophagy
    Li, Xiaoyi
    Li, Xiaohua
    Ma, Huimin
    CHEMICAL SCIENCE, 2020, 11 (06) : 1617 - 1622
  • [24] A new near-infrared ratiometric fluorescent probe for hydrazine
    He, Yangyang
    Li, Zhanxian
    Shi, Bingjie
    An, Zhen
    Yu, Mingming
    Wei, Liuhe
    Ni, Zhonghai
    RSC ADVANCES, 2017, 7 (41): : 25634 - 25639
  • [25] A near-infrared fluorescent probe for the ratiometric detection and living cell imaging of β-galactosidase
    Xueyan Zhang
    Xiangzhu Chen
    Yuanyuan Zhang
    Kaizheng Liu
    Hongjing Shen
    En Zheng
    Xiaoqian Huang
    Shicong Hou
    Xiaodong Ma
    Analytical and Bioanalytical Chemistry, 2019, 411 : 7957 - 7966
  • [26] A near-infrared fluorescent probe for the ratiometric detection and living cell imaging of β-galactosidase
    Zhang, Xueyan
    Chen, Xiangzhu
    Zhang, Yuanyuan
    Liu, Kaizheng
    Shen, Hongjing
    Zheng, En
    Huang, Xiaoqian
    Hou, Shicong
    Ma, Xiaodong
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (30) : 7957 - 7966
  • [27] A near-infrared ratiometric fluorescent probe for cysteine detection over glutathione indicating mitochondrial oxidative stress in vivo
    Yin, Kun
    Yu, Fabiao
    Zhang, Weiwei
    Chen, Lingxin
    BIOSENSORS & BIOELECTRONICS, 2015, 74 : 156 - 164
  • [28] Ratiometric near-infrared fluorescent probes for sensitive detection of pH in live cells
    Wang, Jianbo
    Fang, Mingxi
    Liu, Haiying
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [29] Rational design of a near-infrared dual-emission fluorescent probe for ratiometric imaging of glutathione in cells
    Wang, Shulong
    Li, Zhifang
    Xu, Jiayao
    Lin, Qingyan
    Huang, Wenfang
    Fan, Mingzhu
    Wang, Rong
    Luo, Zhihui
    MICROCHIMICA ACTA, 2024, 191 (02)
  • [30] Rational design of a near-infrared dual-emission fluorescent probe for ratiometric imaging of glutathione in cells
    Shulong Wang
    Zhifang Li
    Jiayao Xu
    Qingyan Lin
    Wenfang Huang
    Mingzhu Fan
    Rong Wang
    Zhihui Luo
    Microchimica Acta, 2024, 191