Initial in vitro testing of a paediatric continuous-flow total artificial heart

被引:13
|
作者
Fukamachi, Kiyotaka [1 ]
Karimov, Jamshid H. [1 ]
Horvath, David J. [2 ]
Sunagawa, Gengo [1 ,3 ]
Byram, Nicole A. [1 ]
Kuban, Barry D. [1 ,5 ]
Moazami, Nader [4 ,6 ]
机构
[1] Cleveland Clin, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] R1 Engn, Euclid, OH USA
[3] Temple Univ, Philadelphia, PA 19122 USA
[4] Cleveland Clin, Kaufman Ctr Heart Failure, Miller Family Heart & Vasc Inst, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44106 USA
[5] Cleveland Clin, Lerner Res Inst, Med Device Solut Elect Core, Cleveland, OH 44106 USA
[6] NYU Langone Hlth, New York, NY USA
关键词
Anatomical fit; Congenital cardiomyopathy; Congenital heart disease; Paediatric devices; Paediatric transition to adult care; VENTRICULAR ASSIST DEVICES; TRANSPLANT; MORTALITY; CHILDREN; SUPPORT;
D O I
10.1093/icvts/ivx429
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. METHODS: The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. RESULTS: Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within +/- 5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. CONCLUSIONS: The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.
引用
收藏
页码:897 / 901
页数:5
相关论文
共 50 条
  • [11] Initial In Vivo Testing of a Self-Balancing Pulsatile Continuous Flow Total Artificial Heart
    Golding, L. A. R.
    Fukamachi, K.
    Horvath, D. J.
    Massiello, A. L.
    Fumoto, H.
    Arakawa, Y.
    Catanese, J.
    Chen, J. -F.
    Mielke, N.
    Horai, T.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S314 - S315
  • [12] Human Fitting Studies of Cleveland Clinic Continuous-Flow Total Artificial Heart
    Karimov, Jamshid H.
    Steffen, Robert J.
    Byram, Nicole
    Sunagawa, Gengo
    Horvath, David
    Cruz, Vincent
    Golding, Leonard A. R.
    Fukamachi, Kiyotaka
    Moazami, Nader
    ASAIO JOURNAL, 2015, 61 (04) : 424 - 428
  • [13] In Vivo Evaluation of the Cleveland Clinic Continuous-Flow Total Artificial Heart in Calves
    Karimov, J. H.
    Fukamachi, K.
    Moazami, N.
    Kobayashi, M.
    Sale, S.
    Mielke, N.
    Sunagawa, G.
    Horvath, D.
    Gao, S.
    Golding, L. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S165 - S166
  • [14] Eight-Year Experience with a Continuous-Flow Total Artificial Heart in Calves
    Cohn, William E.
    Handy, Kelly M.
    Parnis, Steven M.
    Conger, Jeffrey L.
    Winkler, Jo Anna
    Frazier, O. H.
    ASAIO JOURNAL, 2014, 60 (01) : 25 - 30
  • [15] Induced pulsation of a continuous-flow total artificial heart in a mock circulatory system
    Khalil, Hassan A.
    Kerr, Daniel T.
    Schusterman, Mark A., II
    Cohn, William E.
    Frazier, O. H.
    Radovancevic, Branislav
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (05): : 568 - 573
  • [16] Mechanical Circulatory Support for Biventricular Heart Failure Using Continuous-Flow Total Artificial Heart
    Karimov, J. H.
    Horvath, D.
    Byram, N.
    Polakowski, A.
    Adams, J.
    Kado, Y.
    Miyamoto, T.
    Sale, S.
    Kuban, B.
    Fukamachi, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S343 - S343
  • [17] Ninety-Day Survival of a Calf Implanted with a Continuous-Flow Total Artificial Heart
    Cohn, William E.
    Winkler, Jo Anna
    Parnis, Steven
    Costas, Gil G.
    Beathard, Sarah
    Conger, Jeff
    Frazier, O. H.
    ASAIO JOURNAL, 2014, 60 (01) : 15 - 18
  • [18] PEDIATRIC CONTINUOUS-FLOW TOTAL ARTIFICIAL HEART PERFORMANCE: EARLY IN VIVO ASSESSMENT REPORT
    Miyagi, Chihiro
    Kuroda, Taiyo
    Kuban, Barry Dean
    Flick, Christine R.
    Polakowski, Anthony R.
    Fukamachi, Kiyotaka
    Karimov, Jamshid
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 477 - 477
  • [19] Continuous-Flow Total Artificial Heart Supports Long-Term Survival of a Calf
    Frazier, O. H.
    Cohn, William E.
    Tuzun, Egemen
    Winkler, Jo Anna
    Gregoric, Igor D.
    TEXAS HEART INSTITUTE JOURNAL, 2009, 36 (06): : 568 - 574
  • [20] Optimization of axial-pump pressure sensitivity for a continuous-flow total artificial heart
    Frazier, O. H.
    Khalil, Hassan A.
    Benkowski, Robert J.
    Cohn, William E.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (06): : 687 - 691