On Energy Conservation in Data Centers

被引:10
|
作者
Albers, Susanne [1 ]
机构
[1] Tech Univ Munich, D-85748 Garching, Germany
基金
欧洲研究理事会;
关键词
Heterogeneous machines; efficient algorithms; approximation algorithms; minimum-cost flow;
D O I
10.1145/3087556.3087560
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
We formulate and study an optimization problem that arises in the energy management of data centers and, more generally, multiprocessor environments. Data centers host a large number of heterogeneous servers. Each server has an active state and several standby/sleep states with individual power consumption rates. The demand for computing capacity varies over time. Idle servers may be transitioned to low-power modes so as to rightsize the pool of active servers. The goal is to find a state transition schedule for the servers that minimizes the total energy consumed. On a small scale the same problem arises in multi-core architectures with heterogeneous processors on a chip. One has to determine active and idle periods for the cores so as to guarantee a certain service and minimize the consumed energy. For this power/capacity management problem, we develop two main results. We use the terminology of the data center se Sing. First, we investigate the scenario that each server has two states, i.e. an active state and a sleep state. We show that an optimal solution, minimizing energy consumption, can be computed in polynomial time by a combinatorial algorithm. The algorithm resorts to a single-commodity min-cost flow computation. Second, we study the general scenario that each server has an active state and multiple standby/sleep states. We devise a tau-approximation algorithm that relies on a two-commodity min-cost flow computation. Here iota is the number of different server types. A data center has a large collection of machines but only a relatively small number of different server architectures. Moreover, in the optimization one can assign servers with comparable energy consumption to the same class. Technically, both of our algorithms involve non-trivial flow modification procedures. In particular, given a fractional two-commodity flow our algorithm executes advanced rounding and flow packing routines.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 50 条
  • [41] A Hierarchical Approach to Energy Management in Data Centers
    Parolini, Luca
    Garone, Emanuele
    Sinopoli, Bruno
    Krogh, Bruce H.
    49TH IEEE CONFERENCE ON DECISION AND CONTROL (CDC), 2010, : 1065 - 1070
  • [42] Energy aware Colocation of Workload in Data centers
    Pore, Madhurima
    Abbasi, Zahra
    Gupta, Sandeep K. S.
    Varsamopoulos, Georgios
    2012 19TH INTERNATIONAL CONFERENCE ON HIGH PERFORMANCE COMPUTING (HIPC), 2012,
  • [43] Servers and data centers energy performance metrics
    Beitelmal, A. H.
    Fabris, D.
    ENERGY AND BUILDINGS, 2014, 80 : 562 - 569
  • [44] On the Minimization of the Energy Consumption in Federated Data Centers
    Aravanis, Alexis I.
    Karkazis, Panagiotis
    Voulkidis, Artemis
    Zahariadis, Theodore
    INTERNET OF THINGS: IOT INFRASTRUCTURES, PT I, 2016, 169 : 388 - 398
  • [45] AN ECONOMIC ENERGY APPROACH FOR QUERIES ON DATA CENTERS
    Saraiva, Joao
    Guimarales, Miguel
    Belot, Orlando
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT (ICEE 2017), 2017, : 679 - 685
  • [46] First Look at Energy Standard for Data Centers
    Jarnagin, Ron
    ASHRAE JOURNAL, 2016, 58 (10) : 12 - 14
  • [47] A Framework for Optimizing Energy Efficiency in Data Centers
    Gizli, Volkan
    Gomez, Jorge Marx
    FROM SCIENCE TO SOCIETY: NEW TRENDS IN ENVIRONMENTAL INFORMATICS, 2018, : 275 - 282
  • [48] A NEW ENERGY FRUGAL PARADIGM FOR DATA CENTERS
    Little, Adrienne B.
    Garimella, Srinivas
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2010, VOL 5, PTS A AND B, 2012, : 803 - 811
  • [49] Energy Efficient Network Equipment for Data Centers
    Schloesser, Alexander
    Lutz, Stobbe
    Nissen, Nils F.
    Schaeppi, Bernd
    Lang, Klaus-Dieter
    2012 ELECTRONICS GOES GREEN 2012+ (EGG), 2012,
  • [50] Optimization of IT Load and Facility Energy in Data Centers
    Fukumoto, Kunio
    Tamura, Nobuyuki
    Ishibashi, Hideki
    FUJITSU SCIENTIFIC & TECHNICAL JOURNAL, 2010, 46 (04): : 376 - 382