The study of reconstruction image quality resulting from geometric error in micro-CT system

被引:0
|
作者
Xi, Dongxing [1 ,2 ]
Gui, Jianbao [1 ,2 ]
Zou, Jing [1 ,2 ]
Rong, Junyan [1 ,2 ]
Hu, Zhanli [1 ,2 ]
Liu, Xin [1 ,2 ]
Zheng, Hairong [1 ,2 ]
机构
[1] Chinese Acad Sci, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Inst Biomed & Hlth Engn, Shenzhen, Peoples R China
[2] Chinese Acad Sci, Key Lab Biomed Informat & Hlth Engn, Beijing 100864, Peoples R China
关键词
cone-beam CT; geometrical parameter; geometrical calibration; three-dimensional reconstruction; BEAM; CALIBRATION; TOMOGRAPHY; ALGORITHM;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The reconstruction images often suffer from artifacts caused by misaligned geometry of flat detector in micro-CT. This paper mainly simulates the causality between the reconstruction image quality and the flat detector geometry by the eight-spheres phantom. The simulation results show that the most influential parameter is beta (the rotation angle of the detector plane along the center point O) among the five detector parameters, next is a, b, theta and a degressively. We should control a under 7 degrees and a, b offset lower than 8 pixels, when adjusting micro-CT systems. We also show that the relevant correction is efficient to improve the reconstruction image quality affected by the tiny geometric error.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Volumetric micro-CT system for in vivo microscopy
    Badea, CT
    Hedlund, LW
    Wheeler, CT
    Mai, W
    Johnson, GA
    [J]. 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 1377 - 1380
  • [32] The study on the internal structure of a tooth using Micro-CT system.
    Kasahara, N
    Hashimoto, M
    Ide, Y
    [J]. ANTHROPOLOGICAL SCIENCE, 2000, 108 (01) : 125 - 125
  • [33] A micro-CT system for little animal imaging
    Zhong, AJ
    Ye, C
    Luo, QM
    [J]. PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2003, 5254 : 330 - 335
  • [34] Performance Evaluation of a Prototype Micro-CT System
    Cho, Seungryong
    Bian, Junguo
    Pelizzari, Charles A.
    Souris, Jeffrey S.
    Chen, Chin-Tu
    Pan, Xiaochuan
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3127 - 3129
  • [35] A preliminary study on a dual-modality OPT/micro-CT system
    Yang, Yujie
    Dong, Di
    Shi, Liangliang
    Wang, Jun
    Hui, Hui
    Yang, Xin
    Tian, Jie
    [J]. IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES XIII, 2015, 9328
  • [36] Measurement of spatial resolution of the micro-CT system
    Rong Jun-Yan
    Fu Guo-Tao
    Wei Cun-Feng
    Sun Cui-Li
    Wei Long
    [J]. CHINESE PHYSICS C, 2010, 34 (03) : 412 - 416
  • [37] The tracheal system of the Common Wasp (Vespula vulgaris) - A micro-CT study
    Bell, G. D.
    Corps, N.
    Mortimer, D.
    Gretton, S.
    Bury, N.
    Connett, G. J.
    [J]. JOURNAL OF INSECT PHYSIOLOGY, 2023, 149
  • [38] Measurement of spatial resolution of the micro-CT system
    戎军艳
    付国涛
    魏存峰
    孙翠丽
    魏龙
    [J]. Chinese Physics C, 2010, (03) : 412 - 416
  • [39] Framework for iterative cone-beam micro-CT reconstruction
    Benson, T
    Gregor, J
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3253 - 3257
  • [40] Adaptive region of interest method for analytical micro-CT reconstruction
    Yang, Wanneng
    Xu, Xiaochun
    Bi, Kun
    Zeng, Shaoqun
    Liu, Qian
    Chen, Shangbin
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (01) : 23 - 33