Developing gamma-ray tracking with a segmented Ge detector

被引:0
|
作者
Lawrie, E. A. [1 ]
Bucher, T. D. [1 ]
Easton, J. L. [1 ,2 ]
Noncolela, S. P. [1 ,2 ]
Shirinda, O. [1 ]
机构
[1] Natl Res Fdn, IThemba LABS, ZA-7129 Somerset West, South Africa
[2] Univ Western Cape, ZA-7535 Bellville, South Africa
关键词
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
Basic techniques that make it possible to trace the gamma-ray interactions inside a segmented Ge detector and reconstruct the gamma-ray trajectory are discussed. The process of developing gamma-ray tracking in general and the plans for establishing the position sensitivity of the iThemba LABS segmented clover detector are outlined.
引用
收藏
页码:278 / 282
页数:5
相关论文
共 50 条
  • [31] Gamma-ray tracking arrays
    Lieder, RM
    Gast, W
    Jäger, HM
    Mihailescu, L
    Rossewij, M
    Eberth, J
    Pascovici, G
    Thomas, HG
    Weisshaar, D
    Beck, F
    Curien, D
    Duchêne, G
    Pachoud, E
    Piqueras, I
    Alvarez, CR
    Bazzacco, D
    Bellato, M
    Kroell, T
    Manea, C
    Quintana, B
    Venturelli, R
    Napoli, DR
    Rosso, D
    Spolaore, P
    Geraci, A
    Pullia, A
    Ripamonti, G
    Camera, F
    Leoni, S
    Million, B
    Wieland, O
    Bracco, A
    Pignanelli, M
    Brambilla, S
    Lisle, J
    Smith, AG
    Well, R
    Nolan, P
    Boston, A
    Cullen, D
    Descovich, M
    Enqvist, T
    Cederwall, B
    Ideguchi, E
    Van der Marel, J
    Nyberg, J
    Herskind, B
    Sletten, G
    Wilson, J
    Henck, R
    PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, VOL 46: RADIOACTIVE BEAMS IN NUCLEAR AND ASTROPHYSICS, 2001, 46 (01): : 399 - 407
  • [32] Characteristics of gamma-ray energy and timing spectra for a planar-type segmented germanium detector
    Kwon, YK
    Lee, CS
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2003, 42 (05) : 600 - 605
  • [33] A SENSITIVE DIRECTIONAL GAMMA-RAY DETECTOR
    CASSEN, B
    CURTIS, L
    REED, CW
    NUCLEONICS, 1950, 6 (02): : 78 - 81
  • [34] THE GAMMA-RAY HIT DETECTOR AT THE NSCL
    MORRISSEY, DJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 23 - NUCL
  • [35] Waterproof Underwater Gamma-ray Detector
    Seo, Jungmin
    Kim, Soo Mee
    OCEANS 2023 - LIMERICK, 2023,
  • [36] ELEMENTAL ANALYSIS USING NEUTRON CAPTURE GAMMA-RAY TECHNIQUE WITH A GE(LI) DETECTOR
    GREENWOOD, RC
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (01): : 28 - +
  • [37] TECHNIQUES FOR FAST EVALUATION OF GE(LI)-DETECTOR GAMMA-RAY SPECTRA WITH SMALL COMPUTERS
    NYMAN, B
    NUCLEAR INSTRUMENTS & METHODS, 1973, 108 (02): : 237 - 241
  • [38] ABSOLUTE GAMMA-RAY EFFICIENCY OF A 50 CM3 GE(LI) DETECTOR
    YOUNG, FC
    FIGUERA, AS
    PFEUFER, G
    NUCLEAR INSTRUMENTS & METHODS, 1971, 92 (01): : 71 - +
  • [39] USE OF CRYSTAL DIFFRACTION WITH GE DIODE DETECTOR FOR HIGH RESOLUTION GAMMA-RAY SPECTROSCOPY
    SMITHER, RK
    NAMENSON, AI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (01): : 52 - &
  • [40] 10-FOLD DIVIDED TOTAL ABSORPTION GE(LI) GAMMA-RAY DETECTOR
    SUOMINEN, P
    LAHTINEN, T
    NUCLEAR INSTRUMENTS & METHODS, 1976, 133 (02): : 259 - 273