Real-time label-free detection of complement activation products in human serum by white light reflectance spectroscopy

被引:16
|
作者
Petrou, Panagiota S. [2 ]
Ricklin, Daniel [1 ]
Zavali, Maria [3 ]
Raptis, Ioannis [3 ]
Kakabakos, Sotirios E. [2 ]
Misiakos, Konstantinos [3 ]
Lambris, John D. [1 ]
机构
[1] Univ Penn, Dept Pathol & Lab Med, Philadelphia, PA 19104 USA
[2] NCSR Demokritos, Inst Radioisotopes & Radiodiagnost Prod, Immunoassay Immunosensors Lab, GR-15310 Aghia Paraskevi, Greece
[3] NCSR Demokritos, Inst Microelect, GR-15310 Aghia Paraskevi, Greece
来源
BIOSENSORS & BIOELECTRONICS | 2009年 / 24卷 / 11期
基金
美国国家卫生研究院;
关键词
Complement; C3b; White light reflectance spectroscopy; Surface plasmon resonance; Label-free detection; Biomarker analysis; MONOCLONAL-ANTIBODIES; ALTERNATIVE PATHWAY; INTERNAL THIOESTER; C3; COMPONENT; DISEASE; BINDING; C-3;
D O I
10.1016/j.bios.2009.04.040
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present a label-free, real-time sensor based on white light reflectance spectroscopy for quantitating the complement activation product C3b and its metabolites as a biomarker in human serum. Our novel sensor allows real-time monitoring of biomolecular reactions (in this case, antigen-antibody reactions) taking place on a reflective surface within a flow cell. Detection was based on monitoring the increase in film thickness caused by its immunoreaction with a specific antibody; this reaction was seen as a shift in the wavelength at which constructive interference was observed. Quantitation of C3b was achieved by immobilizing a specific mouse monoclonal antibody onto the refractive surface and monitoring the rate of the signal changes occurring during the first 60 s of the immunoreaction between the antibody and known concentrations of purified C3b or dilutions of complement-activated human serum. The lowest detectable concentration of purified C3b was 20 ng/mL, and complement activation products in human serum samples could be detected at dilutions as high as 6000-fold. The advantages of the method include its relatively low cost, short analysis time, and high assay sensitivity and reliability. Thus, this novel assay method can be used to monitor serum C3b produced as a result of complement activation in a variety of normal and pathologic conditions. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3359 / 3364
页数:6
相关论文
共 50 条
  • [41] Label-Free Real-Time Detection of DNA Methylation Based on Quartz Crystal Microbalance Measurement
    Wang, Jie
    Zhu, Zhiqiang
    Ma, Hongwei
    ANALYTICAL CHEMISTRY, 2013, 85 (04) : 2096 - 2101
  • [42] Real-time, Label-free Protein Binding Detection with a One Dimensional Photonic Crystal Sensor
    Guo, Yunbo
    Thomas, Thommey P.
    Ye, Jing Yong
    Myc, Andrzej
    Baker, James R., Jr.
    Norris, Theodore B.
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 1303 - +
  • [43] Real-time small molecule binding detection using a label-free photonic crystal biosensor
    Guo, Yunbo
    Ye, Jing Yong
    Huang, Baohua
    McNerny, Daniel
    Thomas, Thommey P.
    Baker, James R., Jr.
    Norris, Theodore B.
    FRONTIERS IN PATHOGEN DETECTION: FROM NANOSENSORS TO SYSTEMS, 2010, 7553
  • [44] Label-Free and Real-Time Detection of Tuberculosis in Human Urine Samples Using a Nanophotonic Point-of-Care Platform
    Ramirez-Priego, Patricia
    Martens, Daan
    Elamin, Ayssar A.
    Soetaert, Pieterjan
    Van Roy, Wim
    Vos, Rita
    Anton, Birgit
    Bockstaele, Ronny
    Becker, Holger
    Singh, Mahavir
    Bienstman, Peter
    Lechuga, Laura M.
    ACS SENSORS, 2018, 3 (10): : 2079 - 2086
  • [45] Label-Free and Real-Time Detection of Avian Influenza Using Nanowire Field Effect Transistors
    Ahn, Jae-Hyuk
    Im, Maesoon
    Park, Tae Jung
    Lee, Sang Yup
    Choi, Yang-Kyu
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2015, 11 (09) : 1640 - 1643
  • [46] Flexible Mid-infrared Photonic Chips for Real-time and Label-Free Biochemical Detection
    Jin, Tiening
    Lin, Pao Tai
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [47] Label-free detection of gliadin food allergen mediated by real-time apta-PCR
    Pinto, Alessandro
    Nadal Polo, Pedro
    Henry, Olivier
    Bermudo Redondo, M. Carmen
    Svobodova, Marketa
    O'Sullivan, Ciara K.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (02) : 515 - 524
  • [48] Label-free detection of gliadin food allergen mediated by real-time apta-PCR
    Alessandro Pinto
    Pedro Nadal Polo
    Olivier Henry
    M. Carmen Bermudo Redondo
    Marketa Svobodova
    Ciara K. O’Sullivan
    Analytical and Bioanalytical Chemistry, 2014, 406 : 515 - 524
  • [49] Real-Time and Label-Free Detection of the Prostate-Specific Antigen in Human Serum by a Polycrystalline Silicon Nanowire Field-Effect Transistor Biosensor
    Huang, Yu-Wen
    Wu, Chung-Shu
    Chuang, Cheng-Keng
    Pang, See-Tong
    Pan, Tung-Ming
    Yang, Yuh-Shyong
    Ko, Fu-Hsiang
    ANALYTICAL CHEMISTRY, 2013, 85 (16) : 7912 - 7918
  • [50] Recent Developments in the Field of Optical Immunosensors Focusing on a Label-Free, White Light Reflectance Spectroscopy-Based Immunosensing Platform
    Karachaliou, Chrysoula-Evangelia
    Koukouvinos, Georgios
    Goustouridis, Dimitrios
    Raptis, Ioannis
    Kakabakos, Sotirios
    Livaniou, Evangelia
    Petrou, Panagiota
    SENSORS, 2022, 22 (14)