Real-time label-free detection of complement activation products in human serum by white light reflectance spectroscopy

被引:16
|
作者
Petrou, Panagiota S. [2 ]
Ricklin, Daniel [1 ]
Zavali, Maria [3 ]
Raptis, Ioannis [3 ]
Kakabakos, Sotirios E. [2 ]
Misiakos, Konstantinos [3 ]
Lambris, John D. [1 ]
机构
[1] Univ Penn, Dept Pathol & Lab Med, Philadelphia, PA 19104 USA
[2] NCSR Demokritos, Inst Radioisotopes & Radiodiagnost Prod, Immunoassay Immunosensors Lab, GR-15310 Aghia Paraskevi, Greece
[3] NCSR Demokritos, Inst Microelect, GR-15310 Aghia Paraskevi, Greece
来源
BIOSENSORS & BIOELECTRONICS | 2009年 / 24卷 / 11期
基金
美国国家卫生研究院;
关键词
Complement; C3b; White light reflectance spectroscopy; Surface plasmon resonance; Label-free detection; Biomarker analysis; MONOCLONAL-ANTIBODIES; ALTERNATIVE PATHWAY; INTERNAL THIOESTER; C3; COMPONENT; DISEASE; BINDING; C-3;
D O I
10.1016/j.bios.2009.04.040
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present a label-free, real-time sensor based on white light reflectance spectroscopy for quantitating the complement activation product C3b and its metabolites as a biomarker in human serum. Our novel sensor allows real-time monitoring of biomolecular reactions (in this case, antigen-antibody reactions) taking place on a reflective surface within a flow cell. Detection was based on monitoring the increase in film thickness caused by its immunoreaction with a specific antibody; this reaction was seen as a shift in the wavelength at which constructive interference was observed. Quantitation of C3b was achieved by immobilizing a specific mouse monoclonal antibody onto the refractive surface and monitoring the rate of the signal changes occurring during the first 60 s of the immunoreaction between the antibody and known concentrations of purified C3b or dilutions of complement-activated human serum. The lowest detectable concentration of purified C3b was 20 ng/mL, and complement activation products in human serum samples could be detected at dilutions as high as 6000-fold. The advantages of the method include its relatively low cost, short analysis time, and high assay sensitivity and reliability. Thus, this novel assay method can be used to monitor serum C3b produced as a result of complement activation in a variety of normal and pathologic conditions. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3359 / 3364
页数:6
相关论文
共 50 条
  • [1] Real-time multi-analyte label-free detection of proteins by white light-reflectance spectroscopy
    Petrou, Panagiota
    Koukouvinos, Georgios
    Drygiannakis, Dimitrios
    Goustouridis, Dimitris
    Raptis, Ioannis
    Misiakos, Konstantinos
    Kakabakos, Sotirios E.
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS XII, 2014, 8976
  • [2] Label-free kinetic study of biomolecular interactions by white light reflectance spectroscopy
    Zavali, M.
    Petrou, P. S.
    Kakabakos, S. E.
    Kitsara, M.
    Raptis, I.
    Beltsios, K.
    Misiakos, K.
    MICRO & NANO LETTERS, 2006, 1 (02) : 94 - 98
  • [3] Development and Bioanalytical Applications of a White Light Reflectance Spectroscopy Label-Free Sensing Platform
    Koukouvinos, Georgios
    Petrou, Panagiota
    Goustouridis, Dimitrios
    Misiakos, Konstantinos
    Kakabakos, Sotirios
    Raptis, Ioannis
    BIOSENSORS-BASEL, 2017, 7 (04):
  • [4] Real-time label-free nanopore sensor for the detection of anthrax
    Wang, Liang
    Zhou, Shuo
    Chen, Xiaohan
    Guan, Xiyun
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [5] Recent Advances in Real-Time Label-Free Detection of Small Molecules
    Chieng, Andy
    Wan, Zijian
    Wang, Shaopeng
    BIOSENSORS-BASEL, 2024, 14 (02):
  • [6] Label-Free Real-Time Detection of HBsAg Using a QCM Immunosensor
    Saffari, Zahra
    Ghavidel, Amir
    Cohan, Reza Ahangari
    Hamidi-Fard, Mojtaba
    Khobi, Mehdi
    Aghasadeghi, Mohammadreza
    Norouzian, Dariush
    CLINICAL LABORATORY, 2022, 68 (04) : 707 - 720
  • [7] Label-Free and Real-Time Detection of Protein Ubiquitination with a Biological Nanopore
    Wloka, Carsten
    Van Meervelt, Veerle
    van Gelder, Dewi
    Danda, Natasha
    Jager, Nienke
    Williams, Chris P.
    Maglia, Giovanni
    ACS NANO, 2017, 11 (05) : 4387 - 4394
  • [8] A label-free flow-through immunosensor for determination of total- and free-PSA in human serum samples based on white-light reflectance spectroscopy
    Koukouvinos, G.
    Petrou, P. S.
    Misiakos, K.
    Drygiannakis, D.
    Raptis, I.
    Goustouridis, D.
    Kakabakos, S. E.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 1041 - 1048
  • [9] Real-Time, label-free monitorine, of tumor antigen and serum antibody interactions
    Campagnolo, C
    Meyers, KJ
    Ryan, T
    Atkinson, RC
    Chen, YT
    Scanlan, MJ
    Ritter, G
    Old, LJ
    Batt, CA
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 61 (03): : 283 - 298
  • [10] Real-time and label-free detection of chloramphenicol residues with specific molecular interaction
    Dong, Z.
    Huang, G.
    Xu, S.
    Deng, C.
    Zhu, J.
    Chen, S.
    Yang, X.
    Zhao, S.
    JOURNAL OF MICROSCOPY, 2009, 234 (03) : 255 - 261