Adjustable buttons for ACL graft cortical fixation partially fail with cyclic loading and unloading

被引:20
|
作者
Glasbrenner, J. [1 ]
Domnick, C. [1 ]
Raschke, M. J. [1 ]
Willinghoefer, T. [1 ]
Kittl, C. [1 ]
Michel, P. [1 ]
Waehnert, D. [1 ]
Herbort, Mirco [1 ]
机构
[1] Westphalian Wilhelms Univ, Dept Trauma Hand & Reconstruct Surg, Waldeyer Str 1, D-48149 Munster, Germany
关键词
Anterior cruciate ligament reconstruction; Cortical fixation; Adjustable button; Cyclic loading; ANTERIOR CRUCIATE LIGAMENT; INTERFERENCE SCREW FIXATION; SOFT-TISSUE GRAFT; SUSPENSION DEVICES; TIBIAL FIXATION; FIXED-LOOP; RECONSTRUCTION; TUNNEL; TRENDS; LENGTH;
D O I
10.1007/s00167-018-5262-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeDespite good initial pullout strength, it is unclear whether adjustable button (AB) devices for anterior cruciate ligament (ACL) soft-tissue graft fixation, which are based on the Chinese finger trap technique, resist cyclic loading. Furthermore, they have never been tested in a cyclic protocol including complete unloading. It was hypothesized, that the displacement of AB devices with the Chinese finger trap technique would be greater than that of continuous suture loop devices and other available AB mechanisms in a cyclic loading with complete unloading protocol.MethodsACL reconstruction was performed in a porcine knee model using three different types of cortical fixation devices: two different AB devices that use the Chinese finger trap design, one AB device that uses a locked suture loop mechanism and two different continuous loop devices as control groups (n=40). Specimens were mounted in a material-testing machine (Instron Inc.) that permitted 2500 loading and complete unloading cycles to a maximum of 250N, as well as continuous elongation recording. A one-way ANOVA was performed for statistical analysis.ResultsThe displacement of ABs with a Chinese finger trap loop (mean 8.1; SD 1.5mm and mean 6.1; SD 1.4mm) was significantly greater than that of AB with a locked suture loop (mean 4.7; SD 1.0mm; p<0.05) and devices with a continuous loop (mean 4.1; SD 0.5mm and mean 4.4, SD 0.3mm; p<0.01). No significant differences were detected between the ABs with a locked suture loop and the continuous loops.ConclusionCyclic loading and unloading of AB using the Chinese finger trap technique leads to significantly greater construct lengthening compared with other devices. Complete unloading of the ACL is very likely to occur during rehabilitation after ACL reconstruction. Lengthening of the AB device due to cyclic loading might be a potential mode of failure of the ACL graft fixation. Therefore, when using an AB femoral fixation technique, a locked suture loop design or a careful rehabilitation protocol should be considered.
引用
收藏
页码:2530 / 2536
页数:7
相关论文
共 37 条
  • [21] Biomechanical Stability of Third-Generation Adjustable Suture Loop Devices Versus Continuous Loop Button Device for Cortical Fixation of ACL Tendon Grafts
    Deichsel, Adrian
    Leibrandt, Lara
    Raschke, Michael J.
    Klimek, Matthias
    Oeckenpoehler, Simon
    Herbst, Elmar
    Kittl, Christoph
    Glasbrenner, Johannes
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2024, 12 (04)
  • [22] Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading
    Brown, CH
    Wilson, DR
    Hecker, AT
    Ferragamo, M
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (09): : 922 - 935
  • [23] Fixed-loop vs. adjustable-loop cortical button devices for femoral fixation in ACL reconstruction - a systematic review and meta-analysis
    Elmholt, Simone Birkebaek
    Nielsen, Torsten Gronbech
    Lind, Martin
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2022, 9 (01)
  • [24] Fixed-loop vs. adjustable-loop cortical button devices for femoral fixation in ACL reconstruction – a systematic review and meta-analysis
    Simone Birkebæk Elmholt
    Torsten Grønbech Nielsen
    Martin Lind
    Journal of Experimental Orthopaedics, 9
  • [25] Tape-Reinforced Graft Suturing and Retensioning of Adjustable-Loop Cortical Buttons Improve Quadriceps Tendon Autograft Biomechanics in Anterior Cruciate Ligament Reconstruction: A Cadaveric Study
    Lamplot, Joseph D.
    Smith, Benjamin L.
    Slone, Harris S.
    Hauck, Oliver L.
    Wijdicks, Coen A.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (01): : 136 - 145
  • [26] Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques:: The impact of fixation level and fixation method under cyclic loading
    Scheffler, SU
    Südkamp, NP
    Göckenjan, A
    Hoffmann, RFG
    Weiler, A
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (03): : 304 - 315
  • [27] Adjustable- Versus Fixed-Loop Devices for Femoral Fixation in ACL Reconstruction: An In Vitro Full-Construct Biomechanical Study of Surgical Technique-Based Tibial Fixation and Graft Preparation
    Smith, Patrick A.
    Piepenbrink, Marina
    Smith, Shelby K.
    Bachmaier, Samuel
    Bedi, Asheesh
    Wijdicks, Coen A.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2018, 6 (04):
  • [28] In vivo comparison of a fixed loop (EndoButton CL) with an adjustable loop (TightRope RT) device for femoral fixation of the graft in ACL reconstruction: A prospective randomized study and a literature review
    Ranjan, Rahul
    Gaba, Sahil
    Goel, Lakshay
    Asif, Naiyer
    Kalra, Mukesh
    Kumar, Ramesh
    Kumar, Arvind
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (03):
  • [29] A biomechanical comparison of initial fixation strength of 3 different methods of anterior cruciate ligament soft tissue graft tibial fixation - Resistance to monotonic and cyclic loading
    Bartz, Reed L.
    Mossoni, Kory
    Tyber, Jeffrey
    Tokish, John
    Gall, Kenneth
    Siparsky, Patrick N.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (06): : 949 - 954
  • [30] Tunnel widening after ACL reconstruction with different fixation techniques: aperture fixation with biodegradable interference screws versus all-inside technique with suspensory cortical buttons. 5-year data from a prospective randomized trial
    Eichinger, Martin
    Ploner, Martin
    Degenhart, Gerald
    Rudisch, Ansgar
    Smekal, Vinzenz
    Attal, Rene
    Mayr, Raul
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (11) : 6707 - 6718