Effect of Prosthesis Stiffness and Implant Length on the Stress State in Mandibular Bone with Dental Implants

被引:0
|
作者
Todo, M. [1 ]
Irie, K. [1 ]
Matsushita, Y. [2 ]
Koyano, K. [2 ]
机构
[1] Kyushu Univ, Appl Mech Res Inst, Kasuga, Fukuoka 816, Japan
[2] Kyushu Univ, Fac Dent Sci, Fukuoka, Japan
关键词
Mandibular bone; Dental implant; CT image; Finite element analysis; FINITE-ELEMENT-ANALYSIS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to develop a detailed 3-Dimension mandibular model with dental implants on the basis of CT data and to conduct stress analysis to characterize the effects of the material type of prosthesis on stress/strain distribution in the mandibular bone. Three types of materials, a polymer and two metals, with different elastic properties were chosen as the prosthesis materials. The analytical results showed that the Mises equivalent stress and equivalent elastic strain along the circumference of the implant at distal side were much higher than in the anterior region. It was also shown that the stress/strain concentration at the bone increased with decreasing the prosthesis stiffness. The stress/strain concentration observed in the circumference of the implants could be the driving force for loosening and fracture of the implants.
引用
收藏
页码:1611 / +
页数:2
相关论文
共 50 条
  • [41] Effects of prosthesis materials on stress in bone around implants.
    Wang, TM
    Lin, LD
    Wang, JS
    Leu, LJ
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1328 - 1328
  • [42] Mandibular dental implant placement using demineralized bone matrix (DBM)
    Fuentes, Ramon
    Saravia, Diego
    Arias, Alain
    Prieto, Ruth
    Dias, Fernando
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (06): : 2656 - 2660
  • [43] Functional outcomes with dental prosthesis following simultaneous mandibulectomy and mandibular bone reconstruction
    Mochizuki, Yumi
    Omura, Ken
    Harada, Hiroyuki
    Marukawa, Eriko
    Shimamoto, Hiroaki
    Tomioka, Hirofumi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2014, 58 (04) : 259 - 266
  • [44] A MODEL FOR THE IMPLANT-BONE INTERFACE CHARACTERISTICS OF POROUS DENTAL IMPLANTS
    COOK, SD
    KLAWITTER, JJ
    WEINSTEIN, AM
    JOURNAL OF DENTAL RESEARCH, 1982, 61 (08) : 1006 - 1009
  • [45] The bone-implant interface of dental implants in humans on the atomic scale
    Sundell, Gustav
    Dahlin, Christer
    Andersson, Martin
    Thuvander, Mattias
    ACTA BIOMATERIALIA, 2017, 48 : 445 - 450
  • [46] Ultrastructural characterization of the implant/bone interface of immediately loaded dental implants
    Meyer, U
    Joos, U
    Mythili, J
    Stamm, T
    Hohoff, A
    Fillies, T
    Stratmann, U
    Wiesmann, HP
    BIOMATERIALS, 2004, 25 (10) : 1959 - 1967
  • [47] Effect of Dental Implant Micro-thread Designs on Stress Distribution In Bone-Implant Interface
    Tan, S. C.
    Ibrahim, I.
    Daud, R.
    Kamarrudin, N. S.
    JURNAL KEJURUTERAAN, 2022, 34 (02): : 255 - 261
  • [48] Mandibular Flexure and Crestal Bone Stress Distribution on an Implant-Supported Fixed Full Arch Mandibular Prosthesis: Finite Element Analysis in Three Dimensions
    Sharma, Suraj
    Jain, Shashikala
    Gupta, Himanshu
    Gavara, Sai Govind
    Panwar, Pratibha
    Grover, Ramanjeet Kaur
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [49] The Effect of Hypothyroidism on Bone Loss at Dental Implants
    Ursomanno, Brendon L.
    Cohen, Robert E.
    Levine, Michael J.
    Yerke, Lisa M.
    JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (02) : 131 - 134
  • [50] THE EFFECT OF DIAMETER AND LENGTH ON THE PULLOUT STRENGTH OF HYDROXYLAPATITE COATED DENTAL IMPLANTS IN THE ALVEOLAR BONE OF DOGS
    BLOCK, MS
    DELGADO, A
    FONTENOT, MG
    FINGER, IM
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1988, 46 (12) : M22 - M22