Polarimetry with a Laue Lens and CZT Pixel Detector

被引:0
|
作者
Caroli, Ezio [1 ]
da Silva, Rui M. Curado [2 ,3 ]
Stephen, John B. [1 ]
Pisa, Alessandro [2 ]
Auricchio, Natalia [4 ]
del Sordo, Stefano [5 ]
Donati, Ariano [1 ]
Schiavone, Filomena [1 ]
Landini, Gianni [1 ]
Honkimaki, Veijo [6 ]
Frontera, Filippo [4 ]
机构
[1] INAF IASF Bologna, I-40129 Bologna, Italy
[2] Univ Coimbra, Dept Fis, P-3000 Coimbra, Portugal
[3] Catholic Univ Louvain, Ctr Space Radiat, Louvain, Belgium
[4] Univ Ferrara, Dept Phys, I-44100 Ferrara, Italy
[5] INAF IASF Palermo, I-190146 Palermo, Italy
[6] ESRF, F-38043 Grenoble, France
关键词
HARD X-RAY; GREATER-THAN-60; KEV; PROTOTYPE; CRAB;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new generation of high sensitivity telescopes based on the use of Lane lenses coupled with high efficiency solid state focal plane detectors has been identified as a possibility for hard X and soft gamma ray astronomy. For this kind of space mission, polarimetry is recognized as a very important observational parameter and therefore this capability should be included as one of the primary scientific requirements. In this framework our group has realized a small experiment to demonstrate that the combination of a Lane Lens, built using Cu mosaic crystals, with a CZT pixel detector is capable of measuring the polarization of hard X ray sources contemporaneously with spectroscopy and imaging. This experiment was performed at the beginning of March 2008 using the ID15B beam line at ESRF (Grenoble). The experiment was based on a pixel CZT detector (5 mm thick array with 11x11 pixels of 2.5x2.5 mm(2)) with a sensitive area of 3x3 cm(2) in conjunction with a mosaic Cu crystal (15x15 mm(2), 4 mm thick) used in the Laue diffraction configuration. During the tests the Cu crystal was rotated so as to simulate a Lane lens ring, and the detector was moved in order to have the diffracted beam always impinging on the same pixel. The beam at the ID15B have allow us to test the response of this system, with almost 100% linearly polarized photon at similar to 90, 270, 350 keV. In this paper we describe the experimental setup and we report on the preliminary results, with particular emphasis on the evaluation of possible systematic effect introduced in the detected polarization of the impinging photon by the Laue diffraction process.
引用
收藏
页码:4897 / +
页数:2
相关论文
共 50 条
  • [31] Multi-Energy, Fast Counting Hybrid CZT Pixel Detector with Dedicated Readout Integrated Circuit
    Clajus, Martin
    Cajipe, Victoria B.
    Hayakawa, Satoshi
    Tuemer, Tuemay O.
    Willson, Paul D.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3602 - 3606
  • [32] A trapezoidal multilayer Laue lens
    Ji, Bin
    Yue, Shuaipeng
    Li, Ming
    Liu, Peng
    Chang, Guangcai
    OPTICS COMMUNICATIONS, 2025, 574
  • [33] Monte Carlo study of detector concepts for the MAX Laue lens gamma-ray telescope
    G. Weidenspointner
    C. B. Wunderer
    N. Barrière
    A. Zoglauer
    P. von Ballmoos
    Experimental Astronomy, 2005, 20 : 375 - 386
  • [34] Monte Carlo study of detector concepts for the MAX Laue lens gamma-ray telescope
    Weidenspointner, G.
    Wunderer, C. B.
    Barriere, N.
    Zoglauer, A.
    von Ballmoos, P.
    EXPERIMENTAL ASTRONOMY, 2005, 20 (1-3) : 377 - 388
  • [35] Wedged multilayer Laue lens
    Conley, Ray
    Liu, Chian
    Qian, Jun
    Kewish, Cameron M.
    Macrander, Albert T.
    Yan, Hanfei
    Kang, Hyon Chol
    Maser, Joerg
    Stephenson, G. Brian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (05):
  • [36] Design Studies of a CZT-based Detector Combined with a Pixel-Geometry-Matching Collimator for SPECT Imaging
    Weng, Fenghua
    Bagchi, Srijeeta
    Huang, Qiu
    Seo, Youngho
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [37] Hybrid pixel-waveform CdTe/CZT detector for use in an ultrahigh resolution MRI compatible SPECT system
    Cai, Liang
    Meng, Ling-Jian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 101 - 103
  • [38] X-ray polarimetry by means of Compton scattering in the sensor of a hybrid photon counting pixel detector
    Michel, T.
    Durst, J.
    Jakubek, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 603 (03): : 384 - 392
  • [39] CZT Pixel Detectors for Improved SPECT Imaging
    Montemont, Guillaume
    Bordy, Thomas
    Rebuffel, Veronique
    Robert, Charlotte
    Verger, Loick
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4891 - 4896
  • [40] The use of a CZT detector with robotic systems
    Selivanova, Anna
    Hulka, Jiri
    Seifert, Daniel
    Hlavac, Vaclav
    Krsek, Pavel
    Smutny, Vladimir
    Wagner, Libor
    Voltr, Josef
    Rubovic, Peter
    Cespirova, Irena
    Gryc, Lubomir
    APPLIED RADIATION AND ISOTOPES, 2020, 166