A procedure for the simultaneous separation and determination of fission products (lanthanides) and actinides (Pu, Np, U, Am and Cm) is described. The method is based on the use of an anionic/cationic mixed bed chromatographic column (CS5A, Dionex), coupled on-line to an ICP-MS detector. Optimisation of the parameters was carried out with standard solutions containing actinides and lanthanides at the 50 ng ml(-1) concentration level. The effects of different oxidising/reducing agents as well as different mobile phases on the intensity and position of the chromatographic peaks were investigated. The analytical procedure was validated by the use of certified materials as well as by other independent techniques. Analytical figures of merit resulting from the procedure were compared with those obtained using other commercially available ion-exchange stationary phases. The procedure developed was applied to the inventory of spent nuclear fuel samples. Detection limits of 0.25 ng ml(-1) and 0.45 ng ml(-1) were obtained for lanthanides and actinides, respectively. Analytical precision was typical better than 5% over seven repeated measurements.
引用
收藏
页码:1166 / 1171
页数:6
相关论文
共 50 条
  • [41] Determination of trace amount of lead in natural water by isotope dilution - Inductively coupled plasma mass spectrometry
    Department of Applied Chemistry, School of Engineering, Nagoya University, Chikusa-ku, Furo-cho, Nagoya 464-01, Japan
    Anal. Sci., 1600, SUPPL. (7-10):
  • [42] Accurate Determination of Trace Molybdenum in Drinking Water by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry
    Panshu Song
    Jun Wang
    Jingbo Chao
    Qian Wang
    Bing Wu
    Analytical Sciences, 2019, 35 : 807 - 809
  • [43] Determination of bisphosphonate by ion chromatography-inductively coupled mass spectrometry
    Kovacevic, M
    Gartner, A
    Novic, M
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1039 (1-2) : 77 - 82
  • [44] Determination of sulfur in fossil fuels by isotope dilution electrothermal vaporization inductively coupled plasma mass spectrometry
    Yu, LL
    Kelly, WR
    Fassett, JD
    Vocke, RD
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (02) : 140 - 145
  • [45] Determination of trace amount of lead in natural water by isotope dilution - Inductively coupled plasma mass spectrometry
    Itoh, A
    Ozaki, T
    Chiba, K
    Haraguchi, H
    ANALYTICAL SCIENCES, 1997, 13 : 7 - 10
  • [46] Accurate Determination of Trace Molybdenum in Drinking Water by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry
    Song, Panshu
    Wang, Jun
    Chao, Jingbo
    Wang, Qian
    Wu, Bing
    ANALYTICAL SCIENCES, 2019, 35 (07) : 807 - 809
  • [47] Determination of selected nickel isotopes in biological samples by inductively coupled plasma mass spectrometry with isotope dilution
    Patriarca, M
    Lyon, TDB
    McGaw, B
    Fell, GS
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (04) : 297 - 302
  • [48] The accurate determination of potassium and calcium using isotope dilution inductively coupled cold plasma mass spectrometry
    Murphy, Karen E.
    Long, Stephen E.
    Rearick, Michael S.
    Ertas, Özlem S.
    Journal of Analytical Atomic Spectrometry, 2002, 17 (05): : 469 - 477
  • [49] DETERMINATION OF RUBIDIUM BY ISOTOPE-DILUTION INDUCTIVELY-COUPLED PLASMA MASS-SPECTROMETRY AS AN ALTERNATIVE TO THERMAL IONIZATION MASS-SPECTROMETRY
    WARD, DB
    BELL, M
    ANALYTICA CHIMICA ACTA, 1990, 229 (02) : 157 - 162
  • [50] Determination of trace iron in red wine by isotope dilution mass spectrometry using multiple-collector inductively coupled plasma mass spectrometry
    National Institute of Metrology, Beijing 100013, China
    Yuanzineng Kexue Jishu, 2009, 11 (992-996):