Analysis of 3D Prints by X-ray Computed Microtomography and Terahertz Pulsed Imaging

被引:64
|
作者
Markl, Daniel [1 ]
Zeitler, J. Axel [1 ]
Rasch, Cecilie [2 ]
Michaelsen, Maria Hotoft [2 ]
Mullertz, Anette [2 ]
Rantanen, Jukka [2 ]
Rades, Thomas [2 ]
Botker, Johan [2 ]
机构
[1] Univ Cambridge, Dept Chem Engn & Biotechnol, Philippa Fawcett Dr, Cambridge CB3 0AS, England
[2] Univ Copenhagen, Dept Pharm, Univ Pk 2, DK-2100 Copenhagen, Denmark
基金
英国工程与自然科学研究理事会;
关键词
3D printing; microstructure; polyvinyl alcohol (PVA); terahertz pulsed imaging (TPI); X-ray computed microtomography (X mu CT); ORAL DOSAGE FORMS; DRUG-RELEASE; TOMOGRAPHY; DEPOSITION; CT;
D O I
10.1007/s11095-016-2083-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose A 3D printer was used to realise compartmental dosage forms containing multiple active pharmaceutical ingredient (API) formulations. This work demonstrates the microstructural characterisation of 3D printed solid dosage forms using X-ray computed microtomography (X mu CT) and terahertz pulsed imaging (TPI). Methods Printing was performed with either polyvinyl alcohol (PVA) or polylactic acid (PLA). The structures were examined by X mu CT and TPI. Liquid self-nanoemulsifying drug delivery system (SNEDDS) formulations containing saquinavir and halofantrine were incorporated into the 3D printed compartmentalised structures and in vitro drug release determined. Results A clear difference in terms of pore structure between PVA and PLA prints was observed by extracting the porosity (5.5% for PVA and 0.2% for PLA prints), pore length and pore volume from the X mu CT data. The print resolution and accuracy was characterised by X mu CT and TPI on the basis of the computer-aided design (CAD) models of the dosage form (compartmentalised PVA structures were 7.5 +/- 0.75% larger than designed; n = 3). Conclusions The 3D printer can reproduce specific structures very accurately, whereas the 3D prints can deviate from the designed model. The microstructural information extracted by X mu CT and TPI will assist to gain a better understanding about the performance of 3D printed dosage forms.
引用
收藏
页码:1037 / 1052
页数:16
相关论文
共 50 条
  • [21] 3D chemical imaging in the laboratory by hyperspectral X-ray computed tomography
    Egan, C. K.
    Jacques, S. D. M.
    Wilson, M. D.
    Veale, M. C.
    Seller, P.
    Beale, A. M.
    Pattrick, R. A. D.
    Withers, P. J.
    Cernik, R. J.
    SCIENTIFIC REPORTS, 2015, 5
  • [22] Approaches to 3D printing teeth from X-ray microtomography
    Cresswell-Boyes, A. J.
    Barber, A. H.
    Mills, D.
    Tatla, A.
    Davis, G. R.
    JOURNAL OF MICROSCOPY, 2018, 272 (03) : 207 - 212
  • [23] 3D microstructural evolution in sintering observed by X-ray microtomography
    Okuma, Gaku
    JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 2023, 131 (09) : 522 - 532
  • [24] 3D in-vivo X-ray microtomography of living snails
    Postnov, A
    De Clerck, N
    Sasov, A
    Van Dyck, D
    JOURNAL OF MICROSCOPY-OXFORD, 2002, 205 (02): : 201 - 204
  • [25] Design of an X-ray 3D Microtomography Beamline for Full field Hard X-ray Projection Imaging at the Taiwan Photon Source
    Chang, Shih-Hung
    Chang, Chao-Yu
    Liu, Chin-Yen
    Chang, Chia-Feng
    Chiang, Liang-Chih
    Liao, Bo-Yi
    Chen, Yu-Sheng
    Chen, Hsiang-Hsin
    Yang, Shun-Min
    Lee, Tsung-Tse
    Chen, Ying-Jie
    Chen, Fung-Lan
    Hwu, Yeu-Kuang
    13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054
  • [26] Imaging biofilm in porous media using X-ray computed microtomography
    Davit, Y.
    Iltis, G.
    Debenest, G.
    Veran-Tissoires, S.
    Wildenschild, D.
    Gerino, M.
    Quintard, M.
    JOURNAL OF MICROSCOPY, 2011, 242 (01) : 15 - 25
  • [27] Multiscale 3D X-ray imaging
    R. Joseph Kline
    Nature Electronics, 2019, 2 : 435 - 436
  • [28] Analysis of soil and soot deposits by X-ray computed microtomography
    Suman, Alessio
    Vulpio, Alessandro
    Casari, Nicola
    Pinelli, Michele
    di Lillo, Francesca
    D'Amico, Lorenzo
    POWDER TECHNOLOGY, 2021, 394 : 608 - 621
  • [29] Multiscale 3D X-ray imaging
    Kline, R. Joseph
    NATURE ELECTRONICS, 2019, 2 (10) : 435 - 436
  • [30] Porosity Analysis of Two Acrisols by X-Ray Computed Microtomography
    Dowuona, Gabriel N. N.
    Taina, Ioana A.
    Heck, Richard J.
    SOIL SCIENCE, 2009, 174 (11) : 583 - 593