Analysis of 3D Prints by X-ray Computed Microtomography and Terahertz Pulsed Imaging

被引:64
|
作者
Markl, Daniel [1 ]
Zeitler, J. Axel [1 ]
Rasch, Cecilie [2 ]
Michaelsen, Maria Hotoft [2 ]
Mullertz, Anette [2 ]
Rantanen, Jukka [2 ]
Rades, Thomas [2 ]
Botker, Johan [2 ]
机构
[1] Univ Cambridge, Dept Chem Engn & Biotechnol, Philippa Fawcett Dr, Cambridge CB3 0AS, England
[2] Univ Copenhagen, Dept Pharm, Univ Pk 2, DK-2100 Copenhagen, Denmark
基金
英国工程与自然科学研究理事会;
关键词
3D printing; microstructure; polyvinyl alcohol (PVA); terahertz pulsed imaging (TPI); X-ray computed microtomography (X mu CT); ORAL DOSAGE FORMS; DRUG-RELEASE; TOMOGRAPHY; DEPOSITION; CT;
D O I
10.1007/s11095-016-2083-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose A 3D printer was used to realise compartmental dosage forms containing multiple active pharmaceutical ingredient (API) formulations. This work demonstrates the microstructural characterisation of 3D printed solid dosage forms using X-ray computed microtomography (X mu CT) and terahertz pulsed imaging (TPI). Methods Printing was performed with either polyvinyl alcohol (PVA) or polylactic acid (PLA). The structures were examined by X mu CT and TPI. Liquid self-nanoemulsifying drug delivery system (SNEDDS) formulations containing saquinavir and halofantrine were incorporated into the 3D printed compartmentalised structures and in vitro drug release determined. Results A clear difference in terms of pore structure between PVA and PLA prints was observed by extracting the porosity (5.5% for PVA and 0.2% for PLA prints), pore length and pore volume from the X mu CT data. The print resolution and accuracy was characterised by X mu CT and TPI on the basis of the computer-aided design (CAD) models of the dosage form (compartmentalised PVA structures were 7.5 +/- 0.75% larger than designed; n = 3). Conclusions The 3D printer can reproduce specific structures very accurately, whereas the 3D prints can deviate from the designed model. The microstructural information extracted by X mu CT and TPI will assist to gain a better understanding about the performance of 3D printed dosage forms.
引用
收藏
页码:1037 / 1052
页数:16
相关论文
共 50 条
  • [1] Analysis of 3D Prints by X-ray Computed Microtomography and Terahertz Pulsed Imaging
    Daniel Markl
    J. Axel Zeitler
    Cecilie Rasch
    Maria Høtoft Michaelsen
    Anette Müllertz
    Jukka Rantanen
    Thomas Rades
    Johan Bøtker
    Pharmaceutical Research, 2017, 34 : 1037 - 1052
  • [2] A 3D study of mortar degradation by X-ray computed microtomography
    Bernard, D
    Chen, D
    Burlion, N
    COMPUTATIONAL METHODS IN MATERIALS CHARACTERISATION, 2004, 6 : 297 - 306
  • [3] Synchrotron X-ray microtomography for 3D imaging of polymer blends
    Pyun, Ahram
    Bell, Joel R.
    Won, Kyu Hwang
    Weon, Byung Mook
    Seol, Seung Kwon
    Je, Jung Ho
    Macosko, Christopher W.
    MACROMOLECULES, 2007, 40 (06) : 2029 - 2035
  • [4] Use of X-ray microtomography for 3D imaging of internal structures
    Hain, Miroslav
    Bartl, Jan
    Sevcik, Robert
    Jacko, Vlado
    18TH CZECH-POLISH-SLOVAK OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2012, 8697
  • [5] 3D imaging of sugarcane bagasse using X-ray microtomography
    Isaac, A.
    Sket, F.
    Driemeier, C.
    Rocha, G. J. M.
    INDUSTRIAL CROPS AND PRODUCTS, 2013, 49 : 790 - 793
  • [6] High-contrast differentiation resolution 3D imaging of rodent brain by X-ray computed microtomography
    Zikmund, T.
    Novotna, M.
    Kavkova, M.
    Tesarova, M.
    Kaucka, M.
    Szarowska, B.
    Adameyko, I.
    Hruba, E.
    Buchtova, M.
    Drazanova, E.
    Starcuk, Z.
    Kaiser, J.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [7] 3D imaging of fracture propagation using synchrotron X-ray microtomography
    Renard, Francois
    Bernard, Dominique
    Desrues, Jacques
    Ougier-Simonin, Audrey
    EARTH AND PLANETARY SCIENCE LETTERS, 2009, 286 (1-2) : 285 - 291
  • [8] Automatic thresholding method for 3D X-ray microtomography analysis
    Sales, E.
    Pereira, W. C. A.
    Gomez, W.
    Lima, I.
    Lopes, R. T.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING IV, 2014, : 409 - 414
  • [9] X-ray computed tomography for 3D plant imaging
    Piovesan, Agnese
    Vancauwenberghe, Valerie
    Van de Looverbosch, Tim
    Verboven, Pieter
    Nicolai, Bart
    TRENDS IN PLANT SCIENCE, 2021, 26 (11) : 1171 - 1185
  • [10] MICROFOCUS X-RAY SOURCES FOR 3D MICROTOMOGRAPHY
    FLYNN, MJ
    HAMES, SM
    REIMANN, DA
    WILDERMAN, SJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 312 - 315