摘要
Light emitting diode (LED) and compact fluorescent light (CFL) lamps are widely used because they are associated with low energy consumption and a reduced environmental impact. In the present paper, a study of the real consumption of these devices has been carried out. To do this, the active, reactive, distortion and apparent power and electrical efficiency for various lamps have been measured and calculated. The distortions produced in the network provoke the consumed energy to be in the order of 50-75% higher than that which appears in the commercial characteristics. This situation means that for its operation, it is necessary to generate and distribute an amount of energy much higher than that which is declared as the consumption of these lamps, and so far, this amount of energy is neither quantified nor invoiced. Additionally, groups of lamps have also been studied to check whether, when working together on the same network, there is a compensation phenomenon that reduces the negative effects of individual lamps. We have found that this compensation effect does not occur for the type of devices evaluated.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [31] Energy consumption analysis and energy saving strategies for coal mine production in China
    Ge, Shirong (gesr@cumt.edu.cn), 2018, China University of Mining and Technology (47):
  • [32] COMPARATIVE STUDY OF ENERGY SAVING DISCHARGE LAMPS.
    Krishna Murthy, G.S.
    Electrical India, 1987, 27 (11): : 13 - 15
  • [33] Environmental Impacts Analyses of Mercury in Energy Saving Lamps
    Li Yan
    Chen Xin
    Wang Lin
    PROCEEDINGS OF THE 6TH EURO-ASIA CONFERENCE ON ENVIRONMENT AND CSR: TECHNOLOGICAL INNOVATION AND MANAGEMENT SCIENCE SESSION, PT IV, 2010, : 154 - +
  • [34] Energy-saving lamps built by man and machine
    不详
    ASSEMBLY AUTOMATION, 1998, 18 (03) : 240 - 240
  • [35] Impact Assessment of Energy Saving Lamps on Photosensitive Skin
    Fenton, L.
    Ferguson, J.
    Ibbotson, S.
    Moseley, H.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2012, 132 : S122 - S122
  • [36] ENERGY CONSUMPTION AND TECHNICAL POTENTIAL OF ENERGY SAVING IN A HOSPITAL
    Okamoto, S.
    ES2008: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY - 2008, VOL 1, 2009, : 691 - 697
  • [37] Minimum energy consumption process synthesis for energy saving
    Jia Xiao-Ping
    Wang Fang
    Xiang Shu-Guang
    Tan Xin-Sun
    Han Fang-Yu
    RESOURCES CONSERVATION AND RECYCLING, 2008, 52 (07) : 1000 - 1005
  • [38] Energy consumption and energy saving potential in clothing industry
    Cay, Ahmet
    ENERGY, 2018, 159 : 74 - 85
  • [39] Energy consumption and technical potential of energy saving in hospital
    Okamoto, Satoru
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 46 - 53
  • [40] Analysis of Regional Differences in Energy Consumption and Energy saving Potential for Yangtze River Delta
    Wang Di
    Nie Rui
    Shi Hai-ying
    2010 INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND DEVELOPMENT (ICEED2010), 2011, 5 : 690 - 694