Ex vivo evaluation of artifacts mimicking fracture lines on cone-beam computed tomography produced by different root canal sealers

被引:44
|
作者
Brito-Junior, M. [1 ,2 ]
Santos, L. A. N. [3 ]
Faria-e-Silva, A. L. [4 ]
Pereira, R. D. [5 ]
Sousa-Neto, M. D. [2 ]
机构
[1] Univ Estadual Montes Claros, Interinst PhD program, Montes Claros, MG, Brazil
[2] Univ Sao Paulo, Dept Restorat Dent, Fac Dent, BR-14049 Ribeirao Preto, Brazil
[3] Univ Estadual Montes Claros, Dept Dent, Montes Claros, MG, Brazil
[4] Univ Fed Sergipe, Dept Dent, Sch Dent, Aracaju, Brazil
[5] United Univ North Minas, Dept Dent, Montes Claros, MG, Brazil
关键词
cone-beam computed tomography; root canal sealer; root fracture; striking artifacts; INTRACANAL METALLIC POST; VOLUMETRIC TOMOGRAPHY; TREATED TEETH; ABSENCE; SCAN;
D O I
10.1111/iej.12121
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AimTo evaluate streaking artifacts produced by several root canal sealers on CBCT images with variations in voxel resolution. MethodologySingle-rooted premolars were selected and root filled using gutta-percha cones and one of the following sealers: Endofill, Sealer 26, Fillapex or AH Plus. Root canals filled only with gutta-percha were used as control. Scans of teeth using a small-volume CBCT were performed, and the images acquired were evaluated by two calibrated observers (k>0.75). Artifacts were identified as streaks and dark bands on root dentine in axial slices with 2 voxel sizes (0.076 and 0.2mm). Fisher's exact test (P<0.05) was used to compare the presence/absence ratio of artifacts considering the factors sealer' and voxel size'. ResultsFor the 0.20mm voxel size, Sealer 26 had significantly more artifacts than Fillapex (P=0.006) or AH Plus (P=0.017). No differences existed between the sealers when the 0.07mm voxel size was used. Sealer 26 (P=0.042) and Endofill (P=0.035) had significantly more artifacts in the 0.20mm voxel size than with the 0.076mm voxel size, whilst no difference was noted for other filling conditions. ConclusionsThe material used for root filling and the voxel resolution can influence the presence of streaking artifacts observed in CBCT images.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 50 条
  • [1] Root canal sealers affect artifacts on cone-beam computed tomography images
    Hazuki Miyashita
    Rieko Asaumi
    Ayaka Sakamoto
    Taisuke Kawai
    Masaru Igarashi
    Odontology, 2021, 109 : 679 - 686
  • [2] Root canal sealers affect artifacts on cone-beam computed tomography images
    Miyashita, Hazuki
    Asaumi, Rieko
    Sakamoto, Ayaka
    Kawai, Taisuke
    Igarashi, Masaru
    ODONTOLOGY, 2021, 109 (03) : 679 - 686
  • [3] Evaluation of Dental Root Fracture Using Cone-beam Computed Tomography
    Wang, Pei
    Yan, Xue Bing
    Liu, Deng Gao
    Zhang, Wan Lin
    Zhang, Zu Yan
    Ma, Xu Chen
    CHINESE JOURNAL OF DENTAL RESEARCH, 2010, 13 (01): : 31 - 35
  • [4] Investigation on the frequency of streak artifacts resulted from different sealers in cone-beam computed tomography images
    Maserrat, Vida
    Ebrahimi, Heshmat Allah Shahraki
    Moghadam, Maryam Dalaei
    Khodadadnejad, Forough
    Al Ahmadi, Hanane Jami
    GIORNALE ITALIANO DI ENDODONZIA, 2021, 35 (02): : 68 - 74
  • [5] Ex vivo detection of mandibular incisors’ root canal morphology using cone-beam computed tomography with 4 different voxel sizes and micro-computed tomography
    Bingbing Bai
    Ying Tang
    Yihan Wu
    Fan Pei
    Qi Zhu
    Peng Zhu
    Yongchun Gu
    BMC Oral Health, 23
  • [6] Ex vivo detection of mandibular incisors' root canal morphology using cone-beam computed tomography with 4 different voxel sizes and micro-computed tomography
    Bai, Bingbing
    Tang, Ying
    Wu, Yihan
    Pei, Fan
    Zhu, Qi
    Zhu, Peng
    Gu, Yongchun
    BMC ORAL HEALTH, 2023, 23 (01)
  • [7] Evaluation of root canal morphology of maxillary premolars: a cone-beam computed tomography study
    de Lima, Carolina Oliveira
    de Souza, Laura Campos
    Devito, Karina Lopes
    do Prado, Maira
    Campos, Celso Neiva
    AUSTRALIAN ENDODONTIC JOURNAL, 2019, 45 (02) : 196 - 201
  • [8] Evaluation of the nasopalatine canal and variations with cone-beam computed tomography
    Meryem Etoz
    Yıldıray Sisman
    Surgical and Radiologic Anatomy, 2014, 36 : 805 - 812
  • [9] Evaluation of motion artifacts in cone-beam computed tomography with three different patient positioning
    Elif Yildizer Keris
    Oguzhan Demirel
    Melih Ozdede
    Oral Radiology, 2021, 37 : 276 - 281
  • [10] Evaluation of the nasopalatine canal and variations with cone-beam computed tomography
    Etoz, Meryem
    Sisman, Yildiray
    SURGICAL AND RADIOLOGIC ANATOMY, 2014, 36 (08) : 805 - 812