Performance of Harshaw TLD-100H two-element dosemeter

被引:9
|
作者
Luo, L. Z. [1 ]
Rotunda, J. E. [1 ]
机构
[1] Thermo Electron Corp, USA Harshaw TLD, Oakwood Village, OH 44146 USA
关键词
D O I
10.1093/rpd/nci657
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
One of the advantages of LiF based thermoluminescent (TL) materials is its tissue-equivalent property. The Harshaw TLD-100H (LiF:Mg,Cu,P) material has demonstrated that it has a near-flat photon energy response and high sensitivity. With the optimized dosemeter filters built into the holder, the Harshaw TLD-100H two-element dosemeter can be used as a whole body personnel dosemeter for gamma, X ray and beta monitoring without the use of an algorithm or correction factor. This paper presents the dose performance of the Harshaw TLD-100H two-element dosemeter against the ANSI N13.11-2001 standard and the results of tests that are required in IEC 1066 International Standard.
引用
收藏
页码:324 / 330
页数:7
相关论文
共 37 条
  • [1] Performance of the Harshaw DXT-RAD (TLD-100) dosemeter
    Moor, D. M.
    Horspool, B.
    Stokes, R. P.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 533 - 537
  • [2] Further studies in the reduction of residual in Harshaw TLD-100H (LiF:Mg,Cu,P)
    Ramlo, M.
    Moscovitch, M.
    Rotunda, J. E.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 217 - 219
  • [3] Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring
    Freire, L.
    Calado, A.
    Cardoso, J. V.
    Santos, L. M.
    Alves, J. G.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 646 - 650
  • [4] Simultaneous Double Dose Measurements Using TLD-100H
    Stella, Giuseppe
    Sallah, Antouman
    Galvagno, Rosaria
    D'Anna, Alessia
    Gueli, Anna Maria
    CRYSTALS, 2024, 14 (07)
  • [5] Evaluation of Deep and Shallow Doses for OSLD and TLD-100H
    Ikmal, W. N. S. W.
    Samat, S. B.
    Kadir, A. B. A.
    2016 UKM FST POSTGRADUATE COLLOQUIUM, 2016, 1784
  • [6] OSLD Energy Response Performance and Dose Accuracy at 24-1250 keV: Comparison with TLD-100H and TLD-100
    Kadir, A. B. A.
    Priharti, W.
    Samat, S. B.
    Dolah, M. T.
    2013 UKM FST POSTGRADUATE COLLOQUIUM, 2013, 1571 : 108 - 114
  • [7] Robust determination of effective atomic numbers for electron interactions with TLD-100 and TLD-100H thermoluminescent dosimeters
    Taylor, M. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (08): : 770 - 773
  • [8] Application of LiF:Mg, Cu (TLD-100H) Dosimeters for in Diagnostic Radiology
    Sina, S.
    Zeinali, B.
    Karinnipourfard, M.
    Lotfalizadeh, F.
    Sadeghi, M.
    Faghihi, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 131 - 131
  • [9] Glow curve analysis of TLD-100H irradiated with radiation of different LET: Comparison between two theoretical method
    Triolo, A.
    Brai, M.
    Bartolotta, A.
    Marrale, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 560 (02): : 413 - 417
  • [10] Dose profile measurements in a Leksell Gamma Knife using TLD-100H thermoluminescent dosimeters
    Li, Y
    Woollard, J
    Gupta, N
    MEDICAL PHYSICS, 2003, 30 (06) : 1480 - 1480