An accurate fault location method of smart distribution network

被引:0
|
作者
Tan Zhihai [1 ]
Ge Liang [1 ]
Kang Taifeng [1 ]
Zhao Fengqing [1 ]
Zhao Yu [1 ]
Huang Xiaoyun [2 ]
Feng Feijin [2 ]
Li Xiang [2 ]
机构
[1] Beijing Sifang Automat Co Ltd, Beijing, Peoples R China
[2] Foshan Power Supply Bur Guangdong Pawer Grid Corp, Guangzhou, Guangdong, Peoples R China
关键词
Smart Distribution Power Grid; Fault Signal; Fault Diagnose; Accurate Fault Location;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to deal with the global energy crisis and environmental problems, development direction of electric power industry in the new century has become a hot issue of global concern. The smart power grid concept has come into being as the times requires. Smart distribution power grid is an important part of the smart power grid, its core objective is to realize the self-healing distribution power grid. Smart distribution power grid self-healing control technology is one of the smart distribution power grid related problems, which are urgent and need to be focused on. The after fault self-healing control technique is an important content of research on control technology of the smart distribution grid self-healing. By intelligent means, after fault self healing control technology can realize fault diagnosis, fault location, fault isolation and blackout areas fast restoration of power supply, with no or only a small amount of manual intervention, to achieve fast response, fast processing of distribution power grid fault and fast recovery. Based on the optimization of the network reconfiguration, as much as possible fault without losing load, or as little as possible loss of load, in order to achieve fast processing fault, reduce the fault processing time, reduce load power cut area, increase the reliability of the distribution power supply. One method of distribution power grid fault diagnosis and location uses fault detection signal uploaded by FTU installed on feeder column switch and DTU installed in power distribution room, and combines with distribution power grid state when fault occurred. Another method uses fault detection signal uploaded by fault indicator installed on switch and combines with distribution power grid state when fault occurred. An accurate fault location method is proposed in this paper, which uses the fault signal sent by FTU. DTU and fault indicator installed on switch, and combines with distribution power grid state when fault occurred. The method in this paper, defines a unified network topology model of the FTU, DTU or fault indicator installed on the switch and the fault indicator installed in feeder segment. Based uploaded fault signals and topology information when distribution power grid fault, it can do fault diagnosis and precise fault location, and can get accurate fault position between the tower which the fault indicator is installed on. An accurate fault location method proposed in this paper is suitable for overhead lines, cable lines and overhead cable mixed linesand other wirings, suitable for FTU, DTU and fault indicator mixed installation situation, adapts to the actual situation of Chinese distribution power grid, has the characteristics of strong adaptability and easy to use.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Accurate Fault Location Method of Distribution Network with Limited Number of PMUs
    Chen, Xi
    Jiao, Zaibin
    [J]. 2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 1503 - 1507
  • [2] Research on Fault Location Method of Distribution Network
    He, Xiangzhen
    [J]. 6TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2021, 647
  • [3] Short-circuit Fault Location method for Smart Distribution Network Considering load estimation
    Xing, Xiaodong
    Zhang, Hengxu
    Shi, Fang
    Liu, Weisheng
    Liu, Yuanlong
    Ling, Ping
    Bao, Hailong
    [J]. 2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [4] Fault location method for distribution networks using smart meters
    Jamali, Sadegh
    Bahmanyar, Alireza
    Bompard, Ettore
    [J]. MEASUREMENT, 2017, 102 : 150 - 157
  • [5] An Adaptive Fault Location Method for Smart Distribution and Transmission Grids
    Lopes, F. V.
    Santos, W. C.
    Fernandes, D., Jr.
    Neves, W. L. A.
    Souza, B. A.
    [J]. 2011 IEEE PES CONFERENCE ON INNOVATIVE SMART GRID TECHNOLOGIES LATIN AMERICA (ISGT LA), 2011,
  • [6] A Fault Location Method for Active Distribution Network with DGs
    Bao, Wenhong
    Fang, Qian
    Wang, Pin
    Yan, Wenqi
    Pan, Peng
    [J]. 2021 6TH INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA 2021), 2021, : 6 - 10
  • [7] The Fault Location Method of Distribution Network with Fault Indicators Based on Impedance
    Hao, Xinpei
    Meng, Zhaoyong
    Huang, Wuhao
    Tao, Tao
    Wang, Yida
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON AUTOMATION, MECHANICAL CONTROL AND COMPUTATIONAL ENGINEERING, 2015, 124 : 386 - 391
  • [8] An accurate fault location method for distribution network based on active transfer arc-suppression device
    Qiao, Jian
    Yin, Xianggen
    Wang, Yikai
    Xu, Wen
    Tan, Liming
    [J]. ENERGY REPORTS, 2021, 7 : 552 - 560
  • [9] Fault Classification and Location Identification in a Smart Distribution Network Using ANN
    Usman, Muhammad Usama
    Ospina, Juan
    Faruque, Md. Omar
    [J]. 2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [10] Accurate fault location method in distribution networks containing distributed generations
    Jamali, S.
    Talavat, V.
    [J]. Iranian Journal of Electrical and Computer Engineering, 2011, 10 (01): : 27 - 33