Investigation of 3D dynamic and quasistatic models for spinal moments during combined manual material handling tasks

被引:3
|
作者
Harari, Yaar [1 ]
Bechar, Avital [1 ,2 ]
Asci, Simone [3 ]
Riemer, Raziel [1 ]
机构
[1] Ben Gurion Univ Negev, Dept Ind Engn & Management, POB 653, Beer Sheva, Israel
[2] Agr Res Org, Inst Agr Engn, Bet Dagan, Israel
[3] Sapienza Univ Rome, Fac Informat Engn Informat & Stat, Rome, Italy
基金
以色列科学基金会;
关键词
Digital human modeling; L5/S1; moments; Biomechanical model; Ergonomics; DESIGN; VALIDATION; WORKPLACE; SYSTEMS;
D O I
10.1016/j.apergo.2020.103305
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Digital human modeling software uses biomechanical models to compute workers' risk of injury during industrial work processes. In many cases, the biomechanics are calculated using quasistatic models, which neglect the body's dynamics and therefore might be erroneous. This study investigated the differential effect of using a dynamic vs. a quasistatic model on spinal loading during combined manual material handling tasks that are prevalent in industry. An experiment was conducted involving nine male and nine female participants performing a total of 3402 cycles of a box-conveying task (removing, carrying and depositing) for different box masses and shelf heights. Using motion capture data, the peak and cumulative moments acting on the L5/S1 joint were calculated using 3D dynamic and quasistatic models. This revealed that neglecting the dynamic movements (i.e., using a quasistatic model) results in an on average underestimation of 19.7% in the peak spinal moment and 3.6% in the cumulative moment that in some cases exceeds the maximal limit for the compression forces acting on the lower back.
引用
收藏
页数:8
相关论文
共 36 条
  • [31] Investigation on scratching force and material removal mechanism of 3D SiCf/C-SiC composites during single grain scratching
    Zan, Zhuoliang
    Guo, Kai
    Sun, Jie
    Lu, Yuan
    Yang, Bin
    Jia, Xiujie
    Sivalingam, Vinothkumar
    Xi, Jianren
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2022, 42 (13) : 5366 - 5379
  • [32] Using 3D finite element models verified the importance of callus material and microstructure in biomechanics restoration during bone defect repair
    Li, Chentian
    Tan, Rongwei
    Guo, Yuanjun
    Li, Songjian
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2018, 21 (01) : 83 - 90
  • [33] Comparison of 3D dynamic virtual model to link segment model for estimation of net L4/L5 reaction moments during lifting
    Abdoli-Eramaki, Mohammad
    Stevenson, Joan M.
    Agnew, Michael J.
    Kamalzadeh, Amin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2009, 12 (02) : 227 - 237
  • [34] Development of a Dynamic kV Collimator for Low Diagnostic Dose Real-time 3D Motion Tracking during Radiation Therapy by Combined MV-kV Imaging
    Wiersma, R. D.
    Pearson, E.
    Pellizarri, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S582 - S582
  • [35] Development of a Dynamic KV Collimator for Low Diagnostic Dose Real-Time 3D Motion Tracking During Radiation Therapy by Combined MV-KV Imaging
    Wiersma, R.
    Pearson, E.
    Pelizzari, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [36] Application of geometric models to inverted listric fault systems in sandbox experiments. Paper 2: insights for possible along strike migration of material during 3D hanging wall deformation
    Yamada, Y
    McClay, K
    JOURNAL OF STRUCTURAL GEOLOGY, 2003, 25 (08) : 1331 - 1336