The effect of deadtime and electronic transients on the predelay bias in neutron coincidence counting

被引:2
|
作者
Croft, Stephen [1 ]
Favalli, Andrea [2 ]
Swinhoe, Martyn T. [2 ]
Goddard, Braden [3 ]
Stewart, Scott [1 ]
机构
[1] Oak Ridge Natl Lab, 1 Bethel Valley Rd, Oak Ridge, TN 37831 USA
[2] Los Alamos Natl Lab, POB 1663, Los Alamos, NM 87545 USA
[3] Khalifa Univ Sci Technol & Res, POB 127788, Abu Dhabi, U Arab Emirates
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2016年 / 814卷
关键词
Predelay; Neutron coincidence counting; Deadtime;
D O I
10.1016/j.nima.2016.01.022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In neutron coincidence counting using the shift register autocorrelation technique, a predelay is inserted before the opening of the (R+A)-gate. Operationally the purpose of the predelay is to ensure that the (R+A)- and A-gates have matched effectiveness, otherwise a bias will result when the difference between the gates is used to calculate the accidentals corrected net reals coincidence rate. The necessity for the predelay was established experimentally in the early practical development and deployment of the coincidence counting method. The choice of predelay for a given detection system is usually made experimentally, but even today long standing traditional values (e.g., 4.5 mu s) are often used. This, at least in part, reflects the fact that a deep understanding of why a finite predelay setting is needed and how to control the underlying influences has not been fully worked out. In this paper we attempt to gain some insight into the problem. One aspect we consider is the slowing down, thermalization, and diffusion of neutrons in the detector moderator. The other is the influence of deadtime and electronic transients. These may be classified as non-ideal detector behaviors because they are not included in the conventional model used to interpret measurement data. From improved understanding of the effect of dead time and electronic transients on the predelay bias in neutron coincidence counting, the performance of both future and current coincidence counters may be improved. Published by Elsevier B.V.
引用
收藏
页码:96 / 103
页数:8
相关论文
共 50 条
  • [41] A Novel electronic chain for high level neutron coincidence counters
    Fazzi, A
    Pirovano, C
    Varoli, V
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 557 - 562
  • [42] URANIUM AND PLUTONIUM ASSAY OF CREATED WASTE BY GAMMA RAY, SINGLES NEUTRON, AND SLOW NEUTRON COINCIDENCE COUNTING.
    Harlan, Ronald A.
    National Bureau of Standards, Special Publication, 1979, : 622 - 632
  • [43] REMOVING MULTIPLICATION EFFECTS FROM NEUTRON COINCIDENCE COUNTING USING MONTE-CARLO
    STEWART, JE
    ENSSLIN, N
    SCHRANDT, RG
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1979, 33 (NOV): : 442 - 444
  • [44] Application of the coincidence counting technique to DD neutron spectrometry data at the NIF, OMEGA, and Z
    Lahmann, B.
    Milanese, L. M.
    Han, W.
    Johnson, M. Gatu
    Seguin, F. H.
    Frenje, J. A.
    Petrasso, R. D.
    Hahn, K. D.
    Jones, B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [45] Fast neutron dose evaluation using CR39 by coincidence counting process
    Vilela, Eudice
    Brandao, J. O. C.
    Santos, J. A. L.
    de Freitas, F. F.
    NATURAL RADIATION ENVIRONMENT, 2008, 1034 : 509 - 512
  • [46] A Monte Carlo Model for Neutron Coincidence Counting with Fast Organic Liquid Scintillation Detectors
    Gamage, Kelum A. A.
    Joyce, Malcolm J.
    Cave, Frank D.
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [47] AN EPLD-BASED TIME-OF-ARRIVAL ACQUISITION BOARD FOR NEUTRON COINCIDENCE COUNTING
    FAZZI, A
    MILANO, D
    VAROLI, V
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 895 - 899
  • [48] Neutron radiation of an electronic sensor using coincidence method for an active dosimeter
    Ndoye, A
    Cosset, F
    Barelaud, B
    Celerier, A
    Decossas, JL
    Vareille, JC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 423 (2-3): : 414 - 420
  • [49] A generalized multiplication correlation model for the description of fast and thermal neutron multiplication in neutron coincidence counting and time interval analysis
    Baeten, P
    Bruggeman, M
    Carchon, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3): : 466 - 477