Measuring exhaled nitric oxide at high altitude

被引:22
|
作者
Hemmingsson, Tryggve [1 ]
Horn, Astrid [2 ]
Linnarsson, Dag [1 ]
机构
[1] Karolinska Inst, Sect Environm Physiol, Dept Physiol & Pharmacol, SE-17177 Stockholm, Sweden
[2] Luft & Raumfahrtmed Biomed Wissensch Unterstutzun, Deutsch Zentrum, Luft & Raumfahrt Inst, DE-51147 Cologne, Germany
关键词
NO analyser; Partial pressure; Flow regulation; Analyser sensitivity; AIRWAYS;
D O I
10.1016/j.resp.2009.06.002
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The altitude performance of two NO analysers using different NO detectors was studied. The analysers and their flow regulators were tested with simulated exhalations of reference gases. At 4000 m, volume flow was +35% and mass flow -24% of nominal in both instruments. The reduced mass flow increased the exhaled NO fraction by 26% for a given rate of NO excretion. Furthermore, the electrochemical NO detector in one analyser showed an increased signal level for a given partial pressure of test gas. Taken together, these two effects increased the signal output by 60% in comparison to the NO partial pressure. To avoid the, above errors, it is proposed that the flow regulator should be readjusted to give a volume flow of 50 ml s(-1) at the altitude of interest and that the analyser should be recalibrated to the operational altitude. Finally, it is recommended that exhaled NO should always be reported as partial pressure and not as volume fraction, in order to compare measurements at any altitude. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:292 / 298
页数:7
相关论文
共 50 条
  • [21] Measuring exhaled nitric oxide in animal models: methods and clinical implications
    Le-Dong, Nhat-Nam
    Duong-Quy, Sy
    Bei, Yihua
    Hua-Huy, Thong
    Chen, Weihua
    Dinh-Xuan, Anh Tuan
    [J]. JOURNAL OF BREATH RESEARCH, 2012, 6 (04)
  • [22] Reproducibility of a technique for measuring nitric oxide in exhaled air in healthy subjects
    Gutiérrez, CS
    Romero, BR
    Solís, RJ
    Gómez, JC
    [J]. ARCHIVOS DE BRONCONEUMOLOGIA, 2001, 37 (09): : 371 - 374
  • [23] Fractional exhaled nitric oxide-measuring devices: technology update
    Maniscalco, Mauro
    Vitale, Carolina
    Vatrella, Alessandro
    Molino, Antonio
    Bianco, Andrea
    Mazzarella, Gennaro
    [J]. MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2016, 9 : 151 - 160
  • [24] Single high flow exhaled nitric oxide is an imperfect proxy for distal nitric oxide
    Eckel, Sandrah P.
    Salam, Muhammad T.
    [J]. OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2013, 70 (07) : 519 - 520
  • [25] Exhaled nitric oxide and COPD
    Lehtimaki, L.
    Kankaanranta, H.
    Saarelainen, S.
    Moilanen, E.
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2010, 36 (03) : 692 - 692
  • [26] Nitric oxide in exhaled air
    Lundberg, JON
    Weitzberg, E
    Lundberg, JM
    Alving, K
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (12) : 2671 - 2680
  • [27] Exhaled nitric oxide and asthma
    Currie, GP
    Lee, DKC
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (07): : 733 - 733
  • [28] Response to Hemmingsson, Horn and Linnarsson article "Measuring Exhaled Nitric Oxide at High Altitude" Resp Physiol. Neurobiol. 167(3), 292-298
    Laskowski, Daniel
    Beall, Cynthia M.
    Dweik, Raed
    Strohl, Kingman P.
    Hutte, Richard
    Erzurum, Serpil C.
    [J]. RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2010, 170 (01) : 1 - 2
  • [29] Inhaled and exhaled nitric oxide
    B. Thébaud
    J.-F. Arnal
    J. C. Mercier
    A.-T. Dinh-Xuan
    [J]. Cellular and Molecular Life Sciences CMLS, 1999, 55 : 1103 - 1112
  • [30] Exhaled Nitric Oxide in COPD
    Bikov, Andras
    Meszaros, Martina
    Lazar, Zsofia
    [J]. CURRENT RESPIRATORY MEDICINE REVIEWS, 2019, 15 (02) : 71 - 78